1 Gambaran Umum Metode

The wheel hub is thoroughly cleaned with ultrapure water and air-dried. A scraper is used to remove the topcoat, intermediate coating and primer on the surface. After microwave digestion, the concentration of chromium is determined by flame atomic absorption spectrometry at a wavelength of 357.9 nm.

2. Ruang Lingkup Penerapan

Determination of chromium in surface coatings of wheel hubs

3 Standar Referensi

IEC 62312

4 Instruments and Reagents

4.1 Instrumen dan Peralatan

4.1.1 Analytical Instruments

表格

Tidak, tidak. Nama Kuantitas Persyaratan Teknis Aksesoris
1 Spektrofotometer Penyerapan Atom Api 1 set Lampu Katoda Hollow Kromium
2 Acetylene Gas Cylinder 1 silinder Kemurnian ≥ 99,99%
3 Kompresor Udara 1 unit Tekanan knalpot nominal: 0,3 MPa