1 방법 개요

The wheel hub is thoroughly cleaned with ultrapure water and air-dried. A scraper is used to remove the topcoat, intermediate coating and primer on the surface. After microwave digestion, the concentration of chromium is determined by flame atomic absorption spectrometry at a wavelength of 357.9 nm.

2. 적용 범위

Determination of chromium in surface coatings of wheel hubs

3 참조 표준

IEC 62312

4 Instruments and Reagents

4.1 기기 및 장비

4.1.1 Analytical Instruments

表格

아니야 이름 수량 기술적 요구 사항 부속품
1 불꽃 원자 흡수 분광광계는 1 세트 크롬 빈 양극 램프
2 Acetylene Gas Cylinder 1 실린더 순수성 ≥ 99.99%
3 공기 압축기 1 단위 정격 배기 압력: 0.3 MPa