{"id":4336,"date":"2026-01-27T00:00:10","date_gmt":"2026-01-26T16:00:10","guid":{"rendered":"https:\/\/www.pgeneral.com\/?p=4336"},"modified":"2026-01-26T14:19:28","modified_gmt":"2026-01-26T06:19:28","slug":"ftir-vs-raman-spectroscopy-key-differences-and-when-to-use-which","status":"publish","type":"post","link":"https:\/\/www.pgeneral.com\/tr\/news\/ftir-vs-raman-spectroscopy-key-differences-and-when-to-use-which\/","title":{"rendered":"FTIR vs. Raman Spektroskopisi: Anahtar Farkl\u0131l\u0131klar ve Hangisini Ne Zaman Kullanmal\u0131s\u0131n\u0131z"},"content":{"rendered":"<p>&nbsp;<\/p>\n<div style=\"text-align: center;\"><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-4331\" src=\"https:\/\/www.pgeneral.com\/wp-content\/uploads\/2026\/01\/FTIR-vs.-Raman-Spectroscopy-Key-Differences-and-When-to-Use-Which-scaled.webp\" alt=\"FTIR vs. Raman Spektroskopisi Anahtar Farkl\u0131l\u0131klar ve Hangisini Ne Zaman Kullanmal\u0131s\u0131n\u0131z\" width=\"2560\" height=\"1954\" srcset=\"https:\/\/www.pgeneral.com\/wp-content\/uploads\/2026\/01\/FTIR-vs.-Raman-Spectroscopy-Key-Differences-and-When-to-Use-Which-scaled.webp 2560w, https:\/\/www.pgeneral.com\/wp-content\/uploads\/2026\/01\/FTIR-vs.-Raman-Spectroscopy-Key-Differences-and-When-to-Use-Which-300x229.webp 300w, https:\/\/www.pgeneral.com\/wp-content\/uploads\/2026\/01\/FTIR-vs.-Raman-Spectroscopy-Key-Differences-and-When-to-Use-Which-1024x782.webp 1024w, https:\/\/www.pgeneral.com\/wp-content\/uploads\/2026\/01\/FTIR-vs.-Raman-Spectroscopy-Key-Differences-and-When-to-Use-Which-768x586.webp 768w, https:\/\/www.pgeneral.com\/wp-content\/uploads\/2026\/01\/FTIR-vs.-Raman-Spectroscopy-Key-Differences-and-When-to-Use-Which-1536x1172.webp 1536w, https:\/\/www.pgeneral.com\/wp-content\/uploads\/2026\/01\/FTIR-vs.-Raman-Spectroscopy-Key-Differences-and-When-to-Use-Which-2048x1563.webp 2048w, https:\/\/www.pgeneral.com\/wp-content\/uploads\/2026\/01\/FTIR-vs.-Raman-Spectroscopy-Key-Differences-and-When-to-Use-Which-16x12.webp 16w, https:\/\/www.pgeneral.com\/wp-content\/uploads\/2026\/01\/FTIR-vs.-Raman-Spectroscopy-Key-Differences-and-When-to-Use-Which-600x458.webp 600w\" sizes=\"(max-width: 2560px) 100vw, 2560px\" \/><\/div>\n<p>FTIR (Fourier Transform Infrared) spektroskopisi, molek\u00fcllerin orta k\u0131z\u0131l\u00f6tesi radyasyonunu nas\u0131l emip ald\u0131\u011f\u0131n\u0131 kontrol ederek molek\u00fcler titre\u015fimleri tespit eder. Bu desen, kimyasal ba\u011flar\u0131n\u0131n \u00e7e\u015fitli titre\u015fim modlar\u0131na uyuyor. Bir \u00f6rnek IR radyasyonuna kar\u015f\u0131 kar\u015f\u0131ya. Sonra baz\u0131 frekanslar emilir. Bu, oradaki molek\u00fcler yap\u0131ya ve fonksiyonel gruplara dayanarak olur.<\/p>\n<h3 id=\"what-mechanism-drives-signal-generation-in-raman-spectroscopy\"><strong>Raman Spektroskopisinde Sinyal Olu\u015fturmas\u0131n\u0131 Nas\u0131l S\u00fcr\u00fcyor?<\/strong><\/h3>\n<p>Raman spektroskopisi tek renkli \u0131\u015f\u0131\u011f\u0131n elastiksiz da\u011f\u0131lmas\u0131n\u0131 tespit eder. Fotonlar molek\u00fcler titre\u015fimlerle kar\u015f\u0131la\u015f\u0131r. \u00c7o\u011fu elastik olarak geri da\u011f\u0131l\u0131r. Bu&#8217; Rayleigh da\u011f\u0131l\u0131m\u0131. Ama k\u00fc\u00e7\u00fck bir bit enerji de\u011fi\u015ftirir. Bu titre\u015fim modlar\u0131yla e\u015fle\u015fir. Bu&#8217; s Raman da\u011f\u0131l\u0131m\u0131. B\u00f6yle de\u011fi\u015fimler \u00e7ok fazla yap\u0131sal ayr\u0131nt\u0131 verir.<\/p>\n<p>Raman spektroskopisi tek renkli \u0131\u015f\u0131\u011f\u0131n elastiksiz da\u011f\u0131lmas\u0131n\u0131 yakalar. Genellikle lazer kayna\u011f\u0131 kullan\u0131l\u0131r. FTIR'den farkl\u0131 olarak, Raman kutup olmayan ba\u011flar i\u00e7in daha iyi \u00e7al\u0131\u015f\u0131r. C=C, S-S ve aromatik halkalar\u0131 d\u00fc\u015f\u00fcn\u00fcn. Yani simetrik molek\u00fcllere uygundur. Bunlar don&#8217; t IR'de \u00e7ok \u015fey g\u00f6sterir.<\/p>\n<h2 id=\"how-do-instrument-configurations-vary-between-ftir-and-raman\"><strong>FTIR ve Raman aras\u0131nda alet yap\u0131land\u0131rmalar\u0131 nas\u0131l de\u011fi\u015fir?<\/strong><\/h2>\n<p>FTIR aletleri genellikle bir Michelson interferometresine dayan\u0131r. K\u0131z\u0131l\u00f6tesi sinyalini mod\u00fcle eder. Kiri\u015f bir kiri\u015f b\u00f6l\u00fcc\u00fcs\u00fcnden ge\u00e7er. KBr veya ZnSe gibi malzemeler bunu yap\u0131yor. Ayr\u0131c\u0131 \u0131\u015f\u0131k \u0131\u015f\u0131nlar\u0131n\u0131 b\u00f6l\u00fcyor. Sonra onlar\u0131 yeniden birle\u015ftirir. Bu bir m\u00fcdahale deseni olu\u015fturur. Fourier d\u00f6n\u00fc\u015f\u00fcm\u00fc bunu bir emici spektrumuna d\u00f6n\u00fc\u015ft\u00fcr\u00fcr. Bir interferometre kullan\u0131yor. \u00c7o\u011fu sinyal mod\u00fclasyonu i\u00e7in Michelson tipidir. DTGS veya MCT gibi dedekt\u00f6rler yard\u0131mc\u0131 olur. Farkl\u0131 duyarl\u0131l\u0131k ihtiya\u00e7lar\u0131na uyuyorlar.<\/p>\n<h3 id=\"how-is-a-raman-spectrophotometer-architected-for-optimal-performance\"><strong>Raman Spektrofotometri Optimal Performans \u0130\u00e7in Nas\u0131l Mimarl\u0131d\u0131r?<\/strong><\/h3>\n<p>Raman ayar\u0131 heyecan i\u00e7in bir lazer kayna\u011f\u0131 i\u00e7erir. Optik filtreleri de var. Bunlar Raman sinyallerini izole eder. Bir CCD dedekt\u00f6r\u00fc da\u011f\u0131lm\u0131\u015f \u0131\u015f\u0131\u011f\u0131 kaydeder. Mikroskop entegrasyonu y\u00fcksek uzasal \u00e7\u00f6z\u00fcn\u00fcrl\u00fck getirir. Raman y\u0131k\u0131c\u0131 olmayan kal\u0131r. Biraz haz\u0131rl\u0131\u011fa ihtiyac\u0131 var. Yani, hassas veya zor \u00f6rneklere iyi uyar. Bir lazer kayna\u011f\u0131 kullan\u0131yor. Sonra optik filtreler gelir. Bir CCD detekt\u00f6r\u00fc sinyali yakalar.<\/p>\n<h2 id=\"what-sample-conditions-are-best-suited-for-each-technique\"><strong>Hangi \u00d6rnek Ko\u015fullar\u0131 Her Teknik i\u00e7in En Uygun?<\/strong><\/h2>\n<p>FTIR kat\u0131 maddeleri ele al\u0131r. \u00d6rne\u011fin, KBr peletleri iyi \u00e7al\u0131\u015f\u0131r. S\u0131v\u0131 h\u00fccrelerde s\u0131v\u0131 al\u0131r. Gazlar gaz h\u00fccrelerine giriyor. Bununla birlikte, \u00f6rnekler genellikle kurutmaya ihtiya\u00e7 duyar. Su IR'yi g\u00fc\u00e7l\u00fc bir \u015fekilde emir. Bu da anahtar sinyalleri gizleyebilir. Su emimi spektrumlar\u0131 bozabilir. \u00d6rne\u011fin, \u00f6rne\u011fi kurutmak gerekebilir.<\/p>\n<h3 id=\"why-is-raman-preferred-for-aqueous-or-delicate-samples\"><strong>Neden Raman Sulu veya Hassas \u00d6rnekler i\u00e7in Tercih Edilir?<\/strong><\/h3>\n<p>Raman su ortamlar\u0131nda parlar. Su zor m\u00fcdahale eder. Polimerler, pigmentler veya biyolojik dokular gibi malzemelere uygundur. Bunlar IR y\u00f6ntemlerine meydan okuyabilir. \u00d6rnek temas olmamas\u0131 in situ analiz anlam\u0131na gelir. Cam \u015fi\u015feler veya benzer kaplardan kontrol edebilirsiniz. Sulu \u00e7\u00f6z\u00fcmler i\u00e7in harika \u00e7al\u0131\u015f\u0131r. Su m\u00fcdahalesi d\u00fc\u015f\u00fck kal\u0131r.<\/p>\n<h2 id=\"how-do-ftir-and-raman-compare-in-sensitivity-and-selectivity\"><strong>FTIR ve Raman Hassasiyeti ve Se\u00e7imlili\u011fi Nas\u0131l Kar\u015f\u0131la\u015ft\u0131r\u0131l\u0131r?<\/strong><\/h2>\n<p>FTIR kutup ba\u011flar\u0131na g\u00fc\u00e7l\u00fc bir duyarl\u0131l\u0131k verir. Kolayca karbonil uzamalar\u0131n\u0131 (C = O) bulur. Hidroksil gruplar\u0131 (O-H) iyi g\u00f6r\u00fcn\u00fcyor. Aminler (N-H) de bunu yapar. Bunlar\u0131n hepsi IR'yi keskin bir \u015fekilde emiyor. Bu&#8217; Kutup ba\u011flar\u0131na duyarl\u0131.<\/p>\n<h3 id=\"which-molecular-features-are-better-captured-by-raman\"><strong>Hangi Molek\u00fcler \u00d6zellikler Raman taraf\u0131ndan Daha \u0130yi Yakalan\u0131r?<\/strong><\/h3>\n<p>Raman, simetrik ve kutup olmayan ba\u011flar i\u00e7in dikkat \u00e7ekmektedir. C=C \u00e7ift ba\u011flar\u0131n\u0131 a\u00e7\u0131k\u00e7a yakalar. Aromatik sistemler g\u00fc\u00e7l\u00fc g\u00f6r\u00fcn\u00fcyor. Ama baz\u0131 \u00f6rneklerde fluoresans bunu engelleyebilir. Bu zay\u0131f Raman sinyallerini maskeler. Kutup olmayan ba\u011flarla iyi \u00e7al\u0131\u015f\u0131r.<\/p>\n<h2 id=\"how-do-environmental-factors-influence-spectral-quality\"><strong>\u00c7evre Fakt\u00f6rleri Spektral Kaliteyi Nas\u0131l Etkiler?<\/strong><\/h2>\n<p>Oda CO \u2082 and H\u2082 O buhar\u0131 FTIR spektrumlar\u0131na b\u00fcy\u00fck g\u00fcr\u00fclt\u00fc ekler. Sistemlerin temizlenmesi gerekebilir. Kuru hava veya azot yard\u0131mc\u0131 olur. Bu arka plan emilimini kesmektedir. Oda CO \u2082 and H\u2082 O arka plan g\u00fcr\u00fclt\u00fcs\u00fc getirir. Temizleme gerekebilir.<\/p>\n<h3 id=\"how-do-laser-power-and-fluorescence-impact-raman-analysis\"><strong>Lazer G\u00fcc\u00fc ve Floresans Raman Analizi Nas\u0131l Etkiler?<\/strong><\/h3>\n<p>Lazer g\u00fcc\u00fcn\u00fc artt\u0131rmak sinyali g\u00fc\u00e7lendirir. Ama hassas \u015feylere \u0131s\u0131tabilir veya zarar verebilir. Baz\u0131 \u00f6rnekler \u00e7ok floresan. Bu Raman sinyalini bo\u011fuyor. Yani lazer dalga boyunu ve g\u00fcc\u00fcn\u00fc ayarlamak \u00e7ok \u00f6nemlidir. Kirliliklerden gelen floresans zay\u0131f Raman sinyallerini gizleyebilir.<\/p>\n<h2 id=\"when-should-you-choose-ftir-over-raman-or-vice-versa\"><strong>Raman \u00fczerinde FTIR'i Ne Zaman Se\u00e7melisiniz - Yoksa Tersine?<\/strong><\/h2>\n<p>Kutup organik bile\u015fikleri i\u00e7in FTIR se\u00e7in. \u0130\u015flevsel grup kimli\u011fi burada \u00e7ok \u00f6nemlidir. Ayr\u0131ca kalibrasyon modelleri arac\u0131l\u0131\u011f\u0131yla miktarl\u0131 \u00e7al\u0131\u015fmaya da yard\u0131mc\u0131 olur. Polimerlerde veya ila\u00e7larda organik fonksiyonel gruplar\u0131n tespit edilmesi.<\/p>\n<h3 id=\"when-is-raman-spectroscopy-the-better-option\"><strong>Raman Spektroskopisi Ne Zaman Daha \u0130yi Se\u00e7enektir?<\/strong><\/h3>\n<p>Raman kristal maddelere veya inorganik malzemelere uygundur. Minerallar gibi, IR emiliminin gecikti\u011fi yerler. Temiz konteynerler arac\u0131l\u0131\u011f\u0131yla analiz eder. Do\u011frudan temas gerekmez. Bu, adli bilim gibi alanlarda yard\u0131mc\u0131 olur. In situ analizi a\u00e7\u0131k konteynerlerle yap\u0131l\u0131r. \u00d6rnek temas\u0131 gerekmez.<\/p>\n<h2 id=\"can-both-techniques-be-used-together-for-better-results\"><strong>Her iki teknik daha iyi sonu\u00e7lar i\u00e7in birlikte kullan\u0131labilir mi?<\/strong><\/h2>\n<p>&nbsp;<\/p>\n<div style=\"text-align: center;\"><img decoding=\"async\" class=\"aligncenter\" src=\"https:\/\/www.pgeneral.com\/wp-content\/uploads\/2026\/01\/double-beam-scanning-spectrophotometer-T7D-UV-Vis.webp\" alt=\"\u00c7ift \u0131\u015f\u0131n tarama spektrofotometri T7D UV-Vis\" \/><\/div>\n<p>FTIR ve Raman farkl\u0131 titre\u015fim modlar\u0131na \u00e7arpt\u0131. Biri IR aktif kapsar. Di\u011feri Raman aktif. Birlikte, tam bir titre\u015fim resmi verirler. Bu yap\u0131sal anlay\u0131\u015flar\u0131 art\u0131r\u0131r. \u00d6zellikle biyolojik dokular veya nanokompozitler gibi sert malzemeler i\u00e7in. Pratikte, laboratuvarlar genellikle tek ba\u015f\u0131na ka\u00e7\u0131rabilecek ayr\u0131nt\u0131lar\u0131 ortaya \u00e7\u0131karmak i\u00e7in bu ara\u00e7lar\u0131 \u00e7iftle\u015ftirir. \u00d6rne\u011fin, ila\u00e7 form\u00fclasyonlar\u0131n\u0131 incelerken, FTIR kutup etkile\u015fimlerini ortaya \u00e7\u0131kar\u0131rken Raman kristal \u0131zgaradaki simetrik ba\u011flar\u0131 vurgulamaktad\u0131r. B\u00f6yle birle\u015fik yakla\u015f\u0131mlar daha g\u00fcvenilir sonu\u00e7lara ve \u00f6rnek kompozisyonunun daha derin bir anlay\u0131\u015f\u0131na yol a\u00e7ar. Tam titre\u015fim spektrumlar\u0131 sunuyorlar. Bu hem IR-aktif hem de Raman-aktif modlar\u0131 kapsar.<\/p>\n<h2 id=\"who-offers-reliable-solutions-for-these-spectroscopic-needs\"><strong>Bu Spektroskopik \u0130htiya\u00e7lar i\u00e7in G\u00fcvenilir \u00c7\u00f6z\u00fcmler Kim Sunuyor?<\/strong><\/h2>\n<p>Spektroskopide kat\u0131 ara\u00e7lar arayan laboratuvarlar <a style=\"text-decoration: underline;\" href=\"https:\/\/www.pgeneral.com\/tr\/\"><strong>Pansiyon<\/strong><\/a>1991 y\u0131l\u0131nda ba\u015flad\u0131, it&#8217; Y\u00fcksek teknoloji firmas\u0131. R&amp; D, yap\u0131m ve d\u00fcnya \u00e7ap\u0131nda sat\u0131\u015flar\u0131n hepsi \u015firket i\u00e7i. ISO9001 ve CE sertifikalar\u0131 kalitesini ve hassasiyetini geri al\u0131r. PERSEE istikrarl\u0131 yeniliklere odaklanmaktad\u0131r. G\u00fc\u00e7l\u00fc teknik destek sa\u011flar. Ayr\u0131ca, k\u00fcresel eri\u015fim eri\u015fimi kolayla\u015ft\u0131r\u0131r. \u00dcr\u00fcnleri bir\u00e7ok alanda bilim adamlar\u0131na yard\u0131mc\u0131 olur. Do\u011fruluk ve uzun kullan\u0131m i\u00e7in in\u015fa edilen ara\u00e7lar daha iyi bir \u00e7al\u0131\u015fma sa\u011flar. \u00d6rne\u011fin, dizileri rutin kontrollerde veya ileri deneylerde g\u00fcvenilir veriler sa\u011flar. Bu g\u00fcven, ger\u00e7ek d\u00fcnyan\u0131n taleplerini ba\u015far\u0131s\u0131z kar\u015f\u0131layan y\u0131llarca teslim edilen ekipmanlardan kaynaklanmaktad\u0131r. UV \/ VIS spektrofotometrlerinden <a style=\"text-decoration: underline;\" href=\"https:\/\/www.pgeneral.com\/tr\/product\/t7\/\"><strong><u>T7 Serisi<\/u><\/strong><\/a> gibi geli\u015fmi\u015f FTIR sistemlerine <a style=\"text-decoration: underline;\" href=\"https:\/\/www.pgeneral.com\/tr\/product\/ftir8000\/\"><strong><u>FTIR8000<\/u><\/strong><\/a>PERSEE yenilik ve deste\u011fe ba\u011fl\u0131d\u0131r.<\/p>\n<h2 id=\"what-factors-should-guide-your-instrument-selection-process\"><strong>Hangi Fakt\u00f6rler Enstr\u00fcman Se\u00e7im S\u00fcrecinize rehberlik etmeli?<\/strong><\/h2>\n<p>Organik bile\u015fiklerdeki kutup fonksiyonel gruplarla u\u011fra\u015f\u0131rsan\u0131z FTIR'e gidin. Kuru ko\u015fullar buna uygun. Niyetsel analiz de bunu gerektirir. Suzlu kurulumlar, inorganik malzemeler veya h\u0131zl\u0131 haz\u0131rl\u0131k i\u00e7in Raman'\u0131 se\u00e7in. \u00d6zellikle kar\u0131\u015f\u0131k ara\u015ft\u0131rma alanlar\u0131nda tam molek\u00fcler g\u00f6r\u00fcnt\u00fcler i\u00e7in, her iki teknik birlikte en fazla anlay\u0131\u015f verir. Laboratuvar\u0131n\u0131z\u0131 d\u00fc\u015f\u00fcn\u00fcn&#8217; S hedefleri. S\u0131k s\u0131k kullan\u0131lan \u00f6rnek t\u00fcrlerini d\u00fc\u015f\u00fcn\u00fcn. B\u00fct\u00e7e de kullan\u0131m kolayl\u0131\u011f\u0131 gibi bir rol oynar. E\u011fitim ihtiya\u00e7lar\u0131 personel i\u00e7in \u00f6nemlidir.<\/p>\n<h2 id=\"faq\"><strong>S\u0131k Sorulan Sorular<\/strong><\/h2>\n<p><strong>S1: FTIR analizinde spektrofotometrler kullan\u0131rken ana s\u0131n\u0131rlamalar nelerdir?<br \/>\n<\/strong>A1: FTIR spektrofotometreleri atmosferik nem ve CO'yu al\u0131r \u2082  kolayca. Bunlar spektral do\u011frulu\u011fa kar\u0131\u015f\u0131kl\u0131k yap\u0131yor. Temizleme veya arka plan d\u00fczeltmesi bunu d\u00fczeltir, ancak bunu do\u011fru yapmal\u0131s\u0131n\u0131z.<\/p>\n<p><strong>Q2: Raman spektroskopisi FTIR gibi niceliksel analiz i\u00e7in kullan\u0131labilir mi?<br \/>\n<\/strong>A2: Bu&#8217; \u00d6zellikle kalitatif kontroller i\u00e7in. Ancak miktarl\u0131 \u00e7al\u0131\u015fma kalibrasyon modelleri ile \u00e7al\u0131\u015f\u0131r. Lazer yo\u011funlu\u011funu yak\u0131ndan izlemeniz gerekir. \u00d6rnek e\u015fitli\u011fi de say\u0131l\u0131r. Do\u011fru kurulum, \u00e7e\u015fitli uygulamalarda konsantrasyonlar\u0131 \u00f6l\u00e7mek i\u00e7in g\u00fcvenilir hale getirir.<\/p>\n<p><strong>S3: M7 UV \/ VIS spektrofotometri ve FTIR8000 aras\u0131nda nas\u0131l karar verebilirim?<\/strong> Persea'dan sistem mi?<br \/>\nA3: <a style=\"text-decoration: underline;\" href=\"https:\/\/www.pgeneral.com\/tr\/product\/m7\/\"><strong>M7'nin<\/strong><\/a> UV \/ VIS alanlar\u0131nda elektronik ge\u00e7i\u015flere uygundur. Kolorimetrik testler gibi orada parlar. FTIR8000, organik bile\u015fiklerdeki molek\u00fcler titre\u015fimleri ele al\u0131r. Analitlerinize g\u00f6re se\u00e7in&#8217; spektral \u00f6zellikler. Geni\u015f emim verilerine ihtiyac\u0131n\u0131z varsa, FTIR kazan\u0131r. Daha h\u0131zl\u0131 UV kontrolleri i\u00e7in M7'ye gidin. Her ikisi de PERSEE'den kaliteli yap\u0131 ve destek sa\u011flar.<\/p>","protected":false},"excerpt":{"rendered":"<p>&nbsp; FTIR (Fourier Transform Infrared) spectroscopy spots molecular vibrations by checking how molecules absorb mid-infrared radiation. \u00a0This pattern matches various vibrational modes of its chemical bonds. A sample faces IR radiation. Then, certain frequencies get absorbed. This happens based on the molecular structure and functional groups there. What Mechanism Drives Signal Generation in Raman Spectroscopy? [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4331,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[38,37],"tags":[],"class_list":["post-4336","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-information","category-news"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/posts\/4336","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/comments?post=4336"}],"version-history":[{"count":3,"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/posts\/4336\/revisions"}],"predecessor-version":[{"id":4341,"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/posts\/4336\/revisions\/4341"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/media\/4331"}],"wp:attachment":[{"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/media?parent=4336"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/categories?post=4336"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/tags?post=4336"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}