{"id":3997,"date":"2025-10-10T16:54:03","date_gmt":"2025-10-10T08:54:03","guid":{"rendered":"https:\/\/www.pgeneral.com\/?p=3997"},"modified":"2025-10-10T16:54:03","modified_gmt":"2025-10-10T08:54:03","slug":"determination-of-calcium-in-milk-powder-flame-atomic-absorption-spectrometry","status":"publish","type":"post","link":"https:\/\/www.pgeneral.com\/tr\/applications\/determination-of-calcium-in-milk-powder-flame-atomic-absorption-spectrometry","title":{"rendered":"S\u00fct Tozu'ndaki Kalsiyumun Belirlenmesi (Alev Atom Emme Spektrometrisi)"},"content":{"rendered":"<h2 class=\"header-iWP5WJ auto-hide-last-sibling-br\">1. Y\u00f6ntem Genel Bak\u0131\u015f<\/h2>\n<div class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\">\u00d6rnek sindirildikten sonra, serbest b\u0131rak\u0131c\u0131 madde olarak bir lantan \u00e7\u00f6z\u00fcm\u00fc eklenir. \u00d6rnek daha sonra atomik emim spektrometrinde bir alev taraf\u0131ndan atomla\u015ft\u0131r\u0131l\u0131r ve emici 422,7 nm dalga boyunda \u00f6l\u00e7\u00fcl\u00fcr. Belirli bir konsantrasyon aral\u0131\u011f\u0131nda, emici kalsiyum i\u00e7eri\u011fine orant\u0131l\u0131d\u0131r. Niyetsel belirleme standart bir seriyle kar\u015f\u0131la\u015ft\u0131r\u0131larak ger\u00e7ekle\u015ftirilir.<\/div>\n<div>\n<h2 class=\"header-iWP5WJ auto-hide-last-sibling-br\">2. Aletler ve Reagentler<\/h2>\n<h3 class=\"header-iWP5WJ auto-hide-last-sibling-br\">2.1 Aletler ve Ekipmanlar<\/h3>\n<h4 class=\"header-iWP5WJ auto-hide-last-sibling-br\">2.1.1 Test Aletleri<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-cYf_5N\" data-scroll-inline-overflow=\"true\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"false\" data-scroll-inline-end-overflow=\"true\">\n<div class=\"table-scroll-container-Gyf4hQ mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Seri numaras\u0131.<\/th>\n<th>\u0130sim<\/th>\n<th>Miktar<\/th>\n<th>Teknik Gereksinimler<\/th>\n<th>Aksesuarlar<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Alev Atom Emme Spektrofotometri<\/td>\n<td>1 set<\/td>\n<td>&#8211;<\/td>\n<td>Kalsiyum Bo\u015f Katod Lambas\u0131<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Hava Kompres\u00f6r\u00fc<\/td>\n<td>1 set<\/td>\n<td>Nominal bo\u015faltma bas\u0131nc\u0131: 0.3 MPa<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Asetilen Gaz\u0131<\/td>\n<td>1 silindir<\/td>\n<td>Safl\u0131k \u2265% 99,99<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h4 class=\"header-iWP5WJ auto-hide-last-sibling-br\">2.1.2 \u00d6rnek \u00d6n Tedavi Ekipmanlar\u0131<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-cYf_5N\" data-scroll-inline-overflow=\"true\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"false\" data-scroll-inline-end-overflow=\"true\">\n<div class=\"table-scroll-container-Gyf4hQ mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Seri numaras\u0131.<\/th>\n<th>\u0130sim<\/th>\n<th>Miktar<\/th>\n<th>Teknik Gereksinimler<\/th>\n<th>Aksesuarlar<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Elektronik Denge<\/td>\n<td>1 set<\/td>\n<td>Hassasiyet: 0.1 mg<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Kuvars Crucible<\/td>\n<td>Birka\u00e7<\/td>\n<td>Hacim: 100 ml<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Ayarlanabilir Elektrikli F\u0131r\u0131n<\/td>\n<td>1 set<\/td>\n<td>Nominal g\u00fc\u00e7: 2000 W<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>Muffle F\u0131r\u0131n\u0131<\/td>\n<td>1 set<\/td>\n<td>Nominal s\u0131cakl\u0131k: 1000 \u2103<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>Ayarlanabilir S\u0131cak Plaka<\/td>\n<td>1 set<\/td>\n<td>Nominal s\u0131cakl\u0131k aral\u0131\u011f\u0131: Oda s\u0131cakl\u0131\u011f\u0131 ~ 300 \u2103<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>Mikropipet<\/td>\n<td>Her biri 1<\/td>\n<td>Aral\u0131klar\u0131: 100 \u03bcL ~ 1000 \u03bcL, 1000 \u03bcL ~ 5000 \u03bcL<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>hacimli \u015fi\u015fe<\/td>\n<td>Birka\u00e7<\/td>\n<td>Hacimler: 100 mL, 1000 mL<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>8<\/td>\n<td>Kolorimetrik T\u00fcp<\/td>\n<td>Birka\u00e7<\/td>\n<td>Hacim: 50 ml<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h3 class=\"header-iWP5WJ auto-hide-last-sibling-br\">2.2 Reagentler<\/h3>\n<h4 class=\"header-iWP5WJ auto-hide-last-sibling-br\">2.2.1 Ham Reagentler<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-cYf_5N\" data-scroll-inline-overflow=\"true\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"false\" data-scroll-inline-end-overflow=\"true\">\n<div class=\"table-scroll-container-Gyf4hQ mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Seri numaras\u0131.<\/th>\n<th>\u0130sim<\/th>\n<th>Teknik Gereksinimler<\/th>\n<th>Notlar<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Nitrik Asit<\/td>\n<td>MOS S\u0131n\u0131f\u0131<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Hidroklorik Asit<\/td>\n<td>Garantili Reagent (GR)<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Lantan Oksit<\/td>\n<td>Garantili Reagent (GR)<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h4 class=\"header-iWP5WJ auto-hide-last-sibling-br\">2.2 Haz\u0131rlanan Reagentler<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-cYf_5N\" data-scroll-inline-overflow=\"true\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"false\" data-scroll-inline-end-overflow=\"true\">\n<div class=\"table-scroll-container-Gyf4hQ mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Seri numaras\u0131.<\/th>\n<th>\u0130sim<\/th>\n<th>Haz\u0131rlama Y\u00f6ntemi<\/th>\n<th>Notlar<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Nitrik Asit \u00c7\u00f6z\u00fcm\u00fc (5 95)<\/td>\n<td>50 ml nitrik asit \u00f6l\u00e7\u00fcn ve 950 ml su ile ayn\u0131 \u015fekilde kar\u0131\u015ft\u0131r\u0131n.<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Nitrik Asit \u00c7\u00f6z\u00fcm\u00fc (1 1)<\/td>\n<td>50 ml nitrik asit \u00f6l\u00e7\u00fcn ve 50 ml su ile ayn\u0131 \u015fekilde kar\u0131\u015ft\u0131r\u0131n.<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Hidroklorik Asit \u00c7\u00f6z\u00fcm\u00fc (1 1)<\/td>\n<td>50 mL hidroklorik asit \u00f6l\u00e7\u00fcn ve 50 mL suyla ayn\u0131 \u015fekilde kar\u0131\u015ft\u0131r\u0131n.<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h3 class=\"header-iWP5WJ auto-hide-last-sibling-br\">2.3 Referans Standartlar\u0131<\/h3>\n<h4 class=\"header-iWP5WJ auto-hide-last-sibling-br\">2.3.1 Stok \u00c7\u00f6z\u00fcm\u00fc<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-cYf_5N\" data-scroll-inline-overflow=\"true\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"false\" data-scroll-inline-end-overflow=\"true\">\n<div class=\"table-scroll-container-Gyf4hQ mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Seri numaras\u0131.<\/th>\n<th>- Hay\u0131r. - Hay\u0131r.<\/th>\n<th>\u0130sim<\/th>\n<th>Teknik Gereksinimler<\/th>\n<th>Notlar<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>GBW (E) 080261<\/td>\n<td>Kalsiyum Tek Elemanl\u0131 Standart Madde \u00c7\u00f6z\u00fcm\u00fc<\/td>\n<td>Konsantrasyon: 1000 \u03bcg \/ mL<\/td>\n<td>Ulusal Metroloji Enstit\u00fcs\u00fc, \u00c7in<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h2 class=\"header-iWP5WJ auto-hide-last-sibling-br\">3. Operasyonal Prosed\u00fcrler<\/h2>\n<h3 class=\"header-iWP5WJ auto-hide-last-sibling-br\">3.1 \u00d6rnek Haz\u0131rlama<\/h3>\n<h4 class=\"header-iWP5WJ auto-hide-last-sibling-br\">3.1.1 Test \u00c7\u00f6z\u00fcm\u00fcn\u00fcn Haz\u0131rlanmas\u0131<\/h4>\n<ol class=\"auto-hide-last-sibling-br\">\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\">\u00d6rnek \u00d6n muamele<\/p>\n<div class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"><\/div>\n<p>\u00d6rne\u011fin 2 g'ini (0,0001 g'e kadar do\u011fru) 100 mL kuvars ti\u00e7e\u011fine do\u011fru bir \u015fekilde a\u011f\u0131rlay\u0131n. \u00c7ama\u011f\u0131 ayarlanabilir bir elektrikli f\u0131r\u0131na yerle\u015ftirin, duman olu\u015fana kadar karbonize etmek i\u00e7in hafif\u00e7e \u0131s\u0131t\u0131n. \u00c7ama\u011f\u0131 \u00e7\u0131kar\u0131n ve bir muffle f\u0131r\u0131n\u0131na aktar\u0131n, sonra 550 \u2103 da 3 ~ 4 saat boyunca k\u00fcl. So\u011futuktan sonra \u00e7akmay\u0131 \u00e7\u0131kar\u0131n. \u00d6rnek tamamen k\u00fcl de\u011filse, birka\u00e7 damla nitrik asit ekleyin, ayarlanabilir bir s\u0131cak plakaya yerle\u015ftirin, dikkatlice kurulu\u011fa buharla\u015fmak i\u00e7in 150 \u2103 da \u0131s\u0131t\u0131n ve sonra \u00f6rnek beyaz k\u00fcle d\u00f6nene kadar 1 ~ 2 saat daha fazla k\u00fcl yapmak i\u00e7in 550 \u2103 da muffle f\u0131r\u0131n\u0131na geri aktar\u0131n. So\u011futuk ve ti\u00e7e\u011fi \u00e7\u0131kar\u0131n, 2 mL nitrik asit \u00e7\u00f6z\u00fcm\u00fc (1 1) ekleyin, ayarlanabilir s\u0131cak plakaya yerle\u015ftirin, \u00f6rne\u011fi \u00e7\u00f6zmek i\u00e7in 150 \u2103de \u0131s\u0131t\u0131n. So\u011futuktan sonra, \u00e7\u00f6z\u00fcm\u00fc 50 mL kolorimetrik t\u00fcpte su ile i\u015faretlenmi\u015f hacime seyreltin. Ayn\u0131 anda bir reaktif bo\u015f testi yap\u0131n.<\/p><\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\">\u00d6rnek Test \u00c7\u00f6z\u00fcm\u00fcn\u00fcn Haz\u0131rlanmas\u0131<\/p>\n<div class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"><\/div>\n<p>1 mL sindirilmi\u015f \u00e7\u00f6z\u00fcm\u00fc 100 mL hacimli bir kolba pipet edin, 5 mL lantan \u00e7\u00f6z\u00fcm\u00fc (20 g \/ L) ekleyin, i\u015faretlenmi\u015f hacime nitrik asit \u00e7\u00f6z\u00fcm\u00fc (5 95) ile seyreltin ve iyi kar\u0131\u015ft\u0131r\u0131n. Ayn\u0131 \u015fekilde bir reaktif bo\u015flu\u011fu haz\u0131rlay\u0131n. \u00d6rnek eklenmemesi hari\u00e7, bo\u015f test \u00e7\u00f6z\u00fcm\u00fcne eklenen reagentlerin t\u00fcr\u00fc ve miktar\u0131 test \u00e7\u00f6z\u00fcm\u00fcn\u00fcn t\u00fcr\u00fc ve miktar\u0131yla ayn\u0131d\u0131r.<\/p><\/div>\n<\/li>\n<\/ol>\n<h4 class=\"header-iWP5WJ auto-hide-last-sibling-br\">3.1.2 Standart \u00c7\u00f6z\u00fcmlerin Haz\u0131rlanmas\u0131<\/h4>\n<div class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\">Kalsiyum Standart Serisinin Haz\u0131rlanmas\u0131<\/p>\n<div class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"><\/div>\n<p>0 mL, 0,10 mL, 0,20 mL, 0,30 mL ve 0,40 mL kalsiyum standart \u00e7\u00f6z\u00fcm\u00fcn\u00fc (1000 \u03bcg\/mL) s\u0131ras\u0131yla ayr\u0131 100 mL hacimli \u015fi\u015felere pipet edin. Her kolba 5 mL lantan \u00e7\u00f6z\u00fcm\u00fc (20 g\/L) ekleyin, i\u015faretlenmi\u015f hacme nitrik asit \u00e7\u00f6z\u00fcm\u00fc (5 95) ile seyreltin ve iyi kar\u0131\u015ft\u0131r\u0131n. Bu kalsiyum standart serisinin konsantrasyonlar\u0131 0 \u03bcg\/mL, 1.00 \u03bcg\/mL, 2.00 \u03bcg\/mL, 3.00 \u03bcg\/mL ve 4.00 \u03bcg\/mL'dir.<\/p><\/div>\n<h3 class=\"header-iWP5WJ auto-hide-last-sibling-br\">3.2 \u00d6rnek Testi<\/h3>\n<h4 class=\"header-iWP5WJ auto-hide-last-sibling-br\">1) Test Ko\u015fullar\u0131<\/h4>\n<div class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"><strong>Alev Atomik Emme Spektrofotometri i\u00e7in Referans Ko\u015fullar\u0131<\/strong><\/div>\n<div class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"><\/div>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-cYf_5N\" data-scroll-inline-overflow=\"false\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"true\" data-scroll-inline-end-overflow=\"false\">\n<div class=\"table-scroll-container-Gyf4hQ mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Parametre<\/th>\n<th>\u00d6zellikler<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Dalga Uzunlu\u011fu<\/td>\n<td>422,7 nm'lik<\/td>\n<\/tr>\n<tr>\n<td>Spektral Bant Geni\u015fli\u011fi<\/td>\n<td>0,4 nm'lik<\/td>\n<\/tr>\n<tr>\n<td>Element Lamba Ak\u0131m\u0131<\/td>\n<td>3.0 mA'l\u0131k<\/td>\n<\/tr>\n<tr>\n<td>Yan\u0131c\u0131 Y\u00fcksekli\u011fi<\/td>\n<td>10 mm'lik<\/td>\n<\/tr>\n<tr>\n<td>Yak\u0131t Ak\u0131\u015f H\u0131z\u0131<\/td>\n<td>1600 ml \/ dakika<\/td>\n<\/tr>\n<tr>\n<td>Hava Kompres\u00f6r\u00fc Bas\u0131nc\u0131<\/td>\n<td>0,22 MPa'n\u0131n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h4 class=\"header-iWP5WJ auto-hide-last-sibling-br\">2) \u00d6rnek Test<\/h4>\n<div class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\">Kalsiyum standart serisi \u00e7\u00f6z\u00fcmlerini alev atomizat\u00f6r\u00fcne y\u00fckselen konsantrasyon s\u0131ras\u0131nda girin ve emirlerini \u00f6l\u00e7\u00fcn. Standart serideki kalsiyum k\u00fctle konsantrasyonu absisa olarak ve ilgili emici ordinat olarak standart bir e\u011fri \u00e7izin.<\/div>\n<div class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"><\/div>\n<div class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\">Standart \u00e7\u00f6z\u00fcmleri belirlemek i\u00e7in yap\u0131lanlarla ayn\u0131 deneysel ko\u015fullar alt\u0131nda, s\u0131ras\u0131yla bo\u015f \u00e7\u00f6z\u00fcm ve \u00f6rnek test \u00e7\u00f6z\u00fcm\u00fcn\u00fc atomizat\u00f6re girin, ilgili emicilerini \u00f6l\u00e7\u00fcn ve standart serilerle kar\u015f\u0131la\u015ft\u0131r\u0131ld\u0131\u011f\u0131nda miktarsal belirleme ger\u00e7ekle\u015ftirin.<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>1. Method Overview After the sample is digested, a lanthanum solution is added as a releasing agent. The sample is then atomized by a flame in an atomic absorption spectrometer, and the absorbance is measured at a wavelength of 422.7 nm. Within a certain concentration range, the absorbance is proportional to the calcium content. Quantitative [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[36,73],"tags":[],"class_list":["post-3997","post","type-post","status-publish","format-standard","hentry","category-applications","category-food-and-drugs"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/posts\/3997","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/comments?post=3997"}],"version-history":[{"count":0,"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/posts\/3997\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/media?parent=3997"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/categories?post=3997"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/tags?post=3997"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}