{"id":3993,"date":"2025-10-10T16:45:18","date_gmt":"2025-10-10T08:45:18","guid":{"rendered":"https:\/\/www.pgeneral.com\/?p=3993"},"modified":"2025-10-10T16:45:18","modified_gmt":"2025-10-10T08:45:18","slug":"determination-of-chromium-in-refined-sulfur-graphite-furnace-atomic-absorption-spectrometry-2","status":"publish","type":"post","link":"https:\/\/www.pgeneral.com\/tr\/applications\/determination-of-chromium-in-refined-sulfur-graphite-furnace-atomic-absorption-spectrometry-2","title":{"rendered":"Rafinlenmi\u015f K\u00fck\u00fcrtte Kromun Belirlenmesi (Grafit F\u0131r\u0131n\u0131 Atom Emme Spektrometrisi)"},"content":{"rendered":"<h2 class=\"header-iWP5WJ auto-hide-last-sibling-br\">1. Y\u00f6ntem Genel Bak\u0131\u015f<\/h2>\n<div class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\">\u00d6rnek sindirildikten sonra, emilimi grafit f\u0131r\u0131n atomizasyonu yoluyla 357,9 nm dalga boyunda \u00f6l\u00e7\u00fcl\u00fcr. Belirli bir konsantrasyon aral\u0131\u011f\u0131nda, kromun emimlili\u011fi i\u00e7eri\u011fine orant\u0131l\u0131d\u0131r. Niyetsel belirleme standart bir seriyle kar\u015f\u0131la\u015ft\u0131r\u0131larak ger\u00e7ekle\u015ftirilir.<\/div>\n<div>\n<h2 class=\"header-iWP5WJ auto-hide-last-sibling-br\">2. Aletler ve Reagentler<\/h2>\n<\/div>\n<div>\n<h3 class=\"header-iWP5WJ auto-hide-last-sibling-br\">2.1 Aletler ve Ekipmanlar<\/h3>\n<h4 class=\"header-iWP5WJ auto-hide-last-sibling-br\">2.1.1 Test Aletleri<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-cYf_5N\" data-scroll-inline-overflow=\"true\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"false\" data-scroll-inline-end-overflow=\"true\">\n<div class=\"table-scroll-container-Gyf4hQ mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Seri numaras\u0131.<\/th>\n<th>\u0130sim<\/th>\n<th>Miktar<\/th>\n<th>Teknik Gereksinimler<\/th>\n<th>Aksesuarlar<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Grafit F\u0131r\u0131n Atom Emme Spektrofotometri<\/td>\n<td>1 set<\/td>\n<td>&#8211;<\/td>\n<td>Krom Bo\u015f Katod Lambas\u0131<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Sirk\u00fclasyon Su Sistemi<\/td>\n<td>1 set<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Argon Gaz\u0131<\/td>\n<td>1 silindir<\/td>\n<td>Safl\u0131k \u2265% 99,99<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h4 class=\"header-iWP5WJ auto-hide-last-sibling-br\">2.1.2 \u00d6rnek \u00d6n Tedavi Ekipmanlar\u0131<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-cYf_5N\" data-scroll-inline-overflow=\"true\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"false\" data-scroll-inline-end-overflow=\"true\">\n<div class=\"table-scroll-container-Gyf4hQ mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Seri numaras\u0131.<\/th>\n<th>\u0130sim<\/th>\n<th>Miktar<\/th>\n<th>Teknik Gereksinimler<\/th>\n<th>Aksesuarlar<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Porselen Crucible<\/td>\n<td>Birka\u00e7<\/td>\n<td>Hacim: 100 ml<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Elektrikli F\u0131r\u0131n<\/td>\n<td>1 set<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Mikropipet<\/td>\n<td>Her biri 1<\/td>\n<td>Aral\u0131klar\u0131: 100 \u03bcL ~ 1000 \u03bcL, 1000 \u03bcL ~ 5000 \u03bcL<\/td>\n<td>\u0130pu\u00e7lar\u0131: 1 ml, 5 ml<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h3 class=\"header-iWP5WJ auto-hide-last-sibling-br\">2.2 Reagentler<\/h3>\n<h4 class=\"header-iWP5WJ auto-hide-last-sibling-br\">2.2.1 Ham Reagentler<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-cYf_5N\" data-scroll-inline-overflow=\"true\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"false\" data-scroll-inline-end-overflow=\"true\">\n<div class=\"table-scroll-container-Gyf4hQ mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Seri numaras\u0131.<\/th>\n<th>\u0130sim<\/th>\n<th>Teknik Gereksinimler<\/th>\n<th>Notlar<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Nitrik Asit<\/td>\n<td>MOS S\u0131n\u0131f\u0131<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h4 class=\"header-iWP5WJ auto-hide-last-sibling-br\">2.2 Haz\u0131rlanan Reagentler<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-cYf_5N\" data-scroll-inline-overflow=\"true\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"false\" data-scroll-inline-end-overflow=\"true\">\n<div class=\"table-scroll-container-Gyf4hQ mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Seri numaras\u0131.<\/th>\n<th>\u0130sim<\/th>\n<th>Haz\u0131rlama Y\u00f6ntemi<\/th>\n<th>Notlar<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Nitrik Asit \u00c7\u00f6z\u00fcm\u00fc (1 99)<\/td>\n<td>1 mL nitrik asit \u00f6l\u00e7\u00fcn, 99 mL suya ekleyin ve iyi kar\u0131\u015ft\u0131r\u0131n.<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h3 class=\"header-iWP5WJ auto-hide-last-sibling-br\">2.3 Referans Standartlar\u0131<\/h3>\n<h4 class=\"header-iWP5WJ auto-hide-last-sibling-br\">2.3.1 Stok \u00c7\u00f6z\u00fcm\u00fc<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-cYf_5N\" data-scroll-inline-overflow=\"true\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"false\" data-scroll-inline-end-overflow=\"true\">\n<div class=\"table-scroll-container-Gyf4hQ mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Seri numaras\u0131.<\/th>\n<th>- Hay\u0131r. - Hay\u0131r.<\/th>\n<th>\u0130sim<\/th>\n<th>Teknik Gereksinimler<\/th>\n<th>Notlar<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>GSB 04-1740-2004<\/td>\n<td>Ulusal S\u0131v\u0131 Standart \u00d6rne\u011fi &#8211; Krom<\/td>\n<td>Konsantrasyon: 1000 \u03bcg \/ mL<\/td>\n<td>Ulusal Renkli Metal ve Elektronik Malzemeler Analiz ve Test Merkezi taraf\u0131ndan sa\u011flanan<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h2 class=\"header-iWP5WJ auto-hide-last-sibling-br\">3. Operasyonal Prosed\u00fcrler<\/h2>\n<h3 class=\"header-iWP5WJ auto-hide-last-sibling-br\">3.1 \u00d6rnek Haz\u0131rlama<\/h3>\n<h4 class=\"header-iWP5WJ auto-hide-last-sibling-br\">3.1.1 Test \u00c7\u00f6z\u00fcm\u00fcn\u00fcn Haz\u0131rlanmas\u0131<\/h4>\n<div class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\">\u00d6rne\u011fin 5 g a\u011f\u0131rl\u0131\u011f\u0131n\u0131 (0,1 g'e kadar do\u011fru) a\u011f\u0131rlay\u0131n ve 100 mL'lik bir porselen \u00e7ubu\u011fa yerle\u015ftirin. \u00d6rnek yan\u0131ncaya kadar ti\u00e7e\u011fi elektrikli bir f\u0131r\u0131nda \u0131s\u0131t\u0131n. \u00c7ama\u011f\u0131 duman kaposuna ta\u015f\u0131y\u0131n ve k\u00fck\u00fcrt tamamen yanyana kadar bekleyin. Sonra elektrikli f\u0131r\u0131nda 5 dakika daha \u0131s\u0131t\u0131n. \u00c7ama\u011f\u0131 \u00e7\u0131kar\u0131n ve so\u011fumas\u0131na izin verin. 5 ml nitrik asit ve 15 ml su ekleyin, sonra kal\u0131nt\u0131n\u0131n tamamen \u00e7\u00f6z\u00fcnene kadar \u0131s\u0131t\u0131n. So\u011futuktan sonra, \u00e7\u00f6z\u00fcm\u00fc 25 mL kolorimetrik t\u00fcbe aktar\u0131n, i\u015faretlenmi\u015f hacime su ile seyreltin ve iyi kar\u0131\u015ft\u0131r\u0131n.<\/div>\n<h4 class=\"header-iWP5WJ auto-hide-last-sibling-br\">3.1.2 Standart \u00c7\u00f6z\u00fcmlerin Haz\u0131rlanmas\u0131<\/h4>\n<ol class=\"auto-hide-last-sibling-br\">\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\">Krom Standart Ara \u00c7\u00f6z\u00fcm\u00fcn\u00fcn Haz\u0131rlanmas\u0131<\/p>\n<div class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"><\/div>\n<p>100 \u03bcL ulusal krom standart \u00e7\u00f6z\u00fcm\u00fcn\u00fc 100 mL hacimli bir kolba do\u011fru bir \u015fekilde pipetleyin. 1 \u03bcg\/mL konsantrasyonunda bir krom standart ara \u00e7\u00f6z\u00fcm\u00fc elde etmek i\u00e7in (99) nitrik asit \u00e7\u00f6z\u00fcm\u00fc ile i\u015faretlenmi\u015f hacime seyreltin.<\/p><\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\">Krom Standart Serisinin Haz\u0131rlanmas\u0131<\/p>\n<div class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"><\/div>\n<p>0,0, 0,25, 0,5, 1,0 ve 2,0 mL krom standart ara \u00e7\u00f6z\u00fcm\u00fcn\u00fc (1 \u03bcg\/mL) s\u0131ras\u0131yla ayr\u0131 100 mL hacimli \u015fi\u015felere pipet edin. 0,0, 2,5, 5,0, 10,0 ve 20,0 ng\/mL konsantrasyonlar\u0131 olan bir krom standart serisi elde etmek i\u00e7in i\u015faretlenmi\u015f hacme (99) nitrik asit \u00e7\u00f6z\u00fcm\u00fc ekleyin.<\/p><\/div>\n<\/li>\n<\/ol>\n<h3 class=\"header-iWP5WJ auto-hide-last-sibling-br\">3.2 \u00d6rnek Testi<\/h3>\n<h4 class=\"header-iWP5WJ auto-hide-last-sibling-br\">(1) Test Ko\u015fullar\u0131<\/h4>\n<div class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"><strong>Grafit F\u0131r\u0131n Atom Emme Spektrofotometri i\u00e7in Referans Ko\u015fullar\u0131<\/strong><\/div>\n<div class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"><\/div>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-cYf_5N\" data-scroll-inline-overflow=\"false\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"true\" data-scroll-inline-end-overflow=\"false\">\n<div class=\"table-scroll-container-Gyf4hQ mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Parametre<\/th>\n<th>\u00d6zellikler<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Element<\/td>\n<td>Krom (Cr)<\/td>\n<\/tr>\n<tr>\n<td>Dalga Uzunlu\u011fu (nm)<\/td>\n<td>357.9<\/td>\n<\/tr>\n<tr>\n<td>Spektral Bant Geni\u015fli\u011fi (nm)<\/td>\n<td>0.4<\/td>\n<\/tr>\n<tr>\n<td>Element Lamba Ak\u0131m\u0131 (mA)<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>Filtre Kat\u0131s\u0131<\/td>\n<td>0.1<\/td>\n<\/tr>\n<tr>\n<td>Entegrasyon S\u00fcresi (s)<\/td>\n<td>2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"><\/div>\n<div class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"><strong>Grafit F\u0131r\u0131n Is\u0131tma Program\u0131<\/strong><\/div>\n<div class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"><\/div>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-cYf_5N\" data-scroll-inline-overflow=\"true\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"false\" data-scroll-inline-end-overflow=\"true\">\n<div class=\"table-scroll-container-Gyf4hQ mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Element<\/th>\n<th>Kurutma S\u0131cakl\u0131\u011f\u0131 (\u2103)<\/th>\n<th>Kurutma S\u00fcresi (s)<\/th>\n<th>K\u00fcl S\u0131cakl\u0131\u011f\u0131 (\u2103)<\/th>\n<th>K\u00fcl S\u00fcresi (s)<\/th>\n<th>Atomizasyon S\u0131cakl\u0131\u011f\u0131 (\u2103)<\/th>\n<th>Atomizasyon S\u00fcresi (s)<\/th>\n<th>Temizleme S\u0131cakl\u0131\u011f\u0131 (\u2103)<\/th>\n<th>Temizleme S\u00fcresi (s)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Cr'nin<\/td>\n<td>110<\/td>\n<td>20<\/td>\n<td>600<\/td>\n<td>20<\/td>\n<td>2300<\/td>\n<td>3<\/td>\n<td>2400<\/td>\n<td>2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h4 class=\"header-iWP5WJ auto-hide-last-sibling-br\">(2) \u00d6rnek Testi<\/h4>\n<div class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\">Argon silindirini a\u00e7\u0131n ve argon bas\u0131n\u00e7 \u00f6l\u00e7e\u011fini 0,5 MPa'ya ayarlay\u0131n. Aleti optimal \u00e7al\u0131\u015fma durumuna ayarlay\u0131n ve reagent bo\u015flu\u011funun, standart serinin ve \u00f6rnek \u00e7\u00f6z\u00fcm\u00fcn\u00fcn 357.9 nm dalga boyunda emilimini \u00f6l\u00e7\u00fcn.<\/div>\n<div class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"><\/div>\n<div class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\">S\u0131f\u0131r standart \u00e7\u00f6z\u00fcm\u00fcn emilimini her standart \u00e7\u00f6z\u00fcm\u00fcn emiliminden \u00e7\u0131kar\u0131n. Krom k\u00fctle konsantrasyonu (\u03bcg\/L) absisa olarak ve ilgili emici ordinat olarak bir \u00e7al\u0131\u015fma e\u011frisi \u00e7izin. Test \u00e7\u00f6z\u00fcm\u00fcn\u00fcn ve bo\u015f test \u00e7\u00f6z\u00fcm\u00fcn\u00fcn \u00f6l\u00e7\u00fclen emimine dayanarak, \u00e7al\u0131\u015fma e\u011frisinden krom k\u00fctlesini bulun.<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>1. Method Overview After the sample is digested, its absorbance is measured at a wavelength of 357.9 nm via graphite furnace atomization. Within a certain concentration range, the absorbance of chromium is proportional to its content. Quantitative determination is conducted by comparing with a standard series. 2. Instruments and Reagents 2.1 Instruments and Equipment 2.1.1 [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[81,36],"tags":[],"class_list":["post-3993","post","type-post","status-publish","format-standard","hentry","category-petrochemical-and-chemical","category-applications"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/posts\/3993","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/comments?post=3993"}],"version-history":[{"count":0,"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/posts\/3993\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/media?parent=3993"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/categories?post=3993"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/tags?post=3993"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}