{"id":3916,"date":"2025-09-09T11:19:48","date_gmt":"2025-09-09T03:19:48","guid":{"rendered":"https:\/\/www.pgeneral.com\/?p=3916"},"modified":"2025-09-09T11:19:48","modified_gmt":"2025-09-09T03:19:48","slug":"determination-of-copper-in-nylon-flame-atomic-absorption-spectrometry","status":"publish","type":"post","link":"https:\/\/www.pgeneral.com\/tr\/applications\/determination-of-copper-in-nylon-flame-atomic-absorption-spectrometry","title":{"rendered":"Naylonda Bak\u0131r\u0131n Belirlenmesi (Alev Atomik Emme Spektrometrisi)"},"content":{"rendered":"<h2 class=\"header-vfC6AV auto-hide-last-sibling-br\">1. Y\u00f6ntem Genel Bak\u0131\u015f<\/h2>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">\u00d6rnek sindirildikten ve tedavi edildikten sonra alev taraf\u0131ndan atomla\u015ft\u0131r\u0131l\u0131r ve emici 324,8 nm dalga boyunda \u00f6l\u00e7\u00fcl\u00fcr. Belirli bir konsantrasyon aral\u0131\u011f\u0131nda, bak\u0131r\u0131n emici de\u011feri i\u00e7eri\u011fine orant\u0131l\u0131d\u0131r ve standart serilerle kar\u015f\u0131la\u015ft\u0131r\u0131larak miqdarl\u0131k yap\u0131l\u0131r.<\/div>\n<div>\n<h2 class=\"header-vfC6AV auto-hide-last-sibling-br\">2. Aletler ve Reagentler<\/h2>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.1 Aletler ve Ekipmanlar<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.1.1 Test Aletleri<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-GhL7Lo\" data-scroll-inline-overflow=\"true\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"false\" data-scroll-inline-end-overflow=\"true\">\n<div class=\"table-scroll-container-hgHkfW mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Seri numaras\u0131.<\/th>\n<th>\u0130sim<\/th>\n<th>Miktar<\/th>\n<th>Teknik Gereksinimler<\/th>\n<th>Aksesuarlar<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Alev Atom Emme Spektrofotometri<\/td>\n<td>1 set<\/td>\n<td>&#8211;<\/td>\n<td>Bak\u0131r Bo\u015f Katod Lambas\u0131<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Hava Kompres\u00f6r\u00fc<\/td>\n<td>1 set<\/td>\n<td>Nominal bo\u015faltma bas\u0131nc\u0131: 0.3 MPa<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Asetilen Gaz\u0131<\/td>\n<td>1 silindir<\/td>\n<td>Safl\u0131k \u2265% 99,99<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.1.2 \u00d6rnek \u00d6n Tedavi Ekipmanlar\u0131<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-GhL7Lo\" data-scroll-inline-overflow=\"true\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"false\" data-scroll-inline-end-overflow=\"true\">\n<div class=\"table-scroll-container-hgHkfW mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Seri numaras\u0131.<\/th>\n<th>\u0130sim<\/th>\n<th>Miktar<\/th>\n<th>Teknik Gereksinimler<\/th>\n<th>Aksesuarlar<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Elektronik Denge<\/td>\n<td>1 set<\/td>\n<td>Hassasiyet: 0.1 mg<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Kuvars Crucibles<\/td>\n<td>Birka\u00e7<\/td>\n<td>Hacim: 100 ml<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Ayarlanabilir Elektrikli Is\u0131t\u0131c\u0131<\/td>\n<td>1 set<\/td>\n<td>G\u00fc\u00e7: 2000 W<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>Muffle F\u0131r\u0131n\u0131<\/td>\n<td>1 set<\/td>\n<td>Nominal s\u0131cakl\u0131k: 1000 \u2103<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>Ayarlanabilir S\u0131cak Plaka<\/td>\n<td>1 set<\/td>\n<td>S\u0131cakl\u0131k aral\u0131\u011f\u0131: Oda s\u0131cakl\u0131\u011f\u0131 ~ 300 \u2103<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>Mikropipetler<\/td>\n<td>Her biri 1<\/td>\n<td>Hacim aral\u0131klar\u0131: 100 \u03bcL ~ 1000 \u03bcL; 1000 \u03bcL ~ 5000 \u03bcL<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>hacimli \u015fi\u015feler<\/td>\n<td>Birka\u00e7<\/td>\n<td>Hacim: 100 ml<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>8<\/td>\n<td>Kolorimetrik T\u00fcpler<\/td>\n<td>Birka\u00e7<\/td>\n<td>Hacim: 25 ml<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.2 Reagentler<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.2.1 Ham Reagentler<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-GhL7Lo\" data-scroll-inline-overflow=\"false\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"true\" data-scroll-inline-end-overflow=\"false\">\n<div class=\"table-scroll-container-hgHkfW mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Seri numaras\u0131.<\/th>\n<th>\u0130sim<\/th>\n<th>Teknik Gereksinimler<\/th>\n<th>Notlar<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>K\u00fck\u00fcrt Asiti<\/td>\n<td>Garantili Reagent (GR)<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Nitrik Asit<\/td>\n<td>MOS S\u0131n\u0131f\u0131<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.2 Haz\u0131rlanan Reagentler<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-GhL7Lo\" data-scroll-inline-overflow=\"true\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"false\" data-scroll-inline-end-overflow=\"true\">\n<div class=\"table-scroll-container-hgHkfW mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Seri numaras\u0131.<\/th>\n<th>\u0130sim<\/th>\n<th>Haz\u0131rlama Y\u00f6ntemi<\/th>\n<th>Notlar<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Nitrik Asit \u00c7\u00f6z\u00fcm\u00fc (1 9)<\/td>\n<td>10 mL nitrik asit \u00f6l\u00e7\u00fcn, 90 mL suya ekleyin ve iyi kar\u0131\u015ft\u0131r\u0131n.<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.3 Referans Standartlar\u0131<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.3.1 Stok \u00c7\u00f6z\u00fcm\u00fc<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-GhL7Lo\" data-scroll-inline-overflow=\"true\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"false\" data-scroll-inline-end-overflow=\"true\">\n<div class=\"table-scroll-container-hgHkfW mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Seri numaras\u0131.<\/th>\n<th>- Hay\u0131r. - Hay\u0131r.<\/th>\n<th>\u0130sim<\/th>\n<th>Teknik Gereksinimler<\/th>\n<th>Notlar<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>GBW08615 Hakk\u0131nda<\/td>\n<td>Bak\u0131r Tek Elemanl\u0131 Standart \u00c7\u00f6z\u00fcm<\/td>\n<td>Konsantrasyon: 1000 \u03bcg \/ mL<\/td>\n<td>Ulusal Metroloji Enstit\u00fcs\u00fc, \u00c7in<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h2 class=\"header-vfC6AV auto-hide-last-sibling-br\">3. Operasyon Prosed\u00fcr\u00fc<\/h2>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.1 \u00d6rnek Haz\u0131rlama<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.1.1 Test \u00c7\u00f6z\u00fcm\u00fcn\u00fcn Haz\u0131rlanmas\u0131<\/h4>\n<ol class=\"auto-hide-last-sibling-br\">\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">\u00d6rnek \u00d6n muamele<br class=\"container-utlnW2 wrapper-d0Cc1k undefined\" \/>1,0 g kat\u0131 \u00f6rnek (0,0001 g'e kadar do\u011fru) bir kuvars ti\u00e7e\u011fine a\u011f\u0131rlay\u0131n, 1 mL s\u00fclf\u00fcrik asit ekleyin, duman \u00fcretilmene kadar karbonizasyon i\u00e7in ayarlanabilir bir elektrikli \u0131s\u0131t\u0131c\u0131 \u00fczerinde hafif\u00e7e \u0131s\u0131t\u0131n. Ta\u00e7ay\u0131 550 \u2103 da 3-4 saat boyunca bir muffle f\u0131r\u0131n\u0131na ve k\u00fcle aktar\u0131n. So\u011fuk ve \u00e7akmay\u0131 \u00e7\u0131kar. Tam olmayan k\u00fcll\u00fc \u00f6rnekler i\u00e7in birka\u00e7 damla nitrik asit ekleyin, ti\u00e7e\u011fi ayarlanabilir bir s\u0131cak plakaya yerle\u015ftirin, 150 \u2103 de \u0131s\u0131t\u0131n ve dikkatlice kurulu\u011fa buharla\u015f\u0131n. Daha sonra 550 \u2103 da muffle f\u0131r\u0131n\u0131na geri aktar\u0131n ve \u00f6rnek tamamen k\u00fcllenene kadar 1-2 saat k\u00fcllemeye devam edin. So\u011futuk ve ti\u00e7e\u011fi \u00e7\u0131kar\u0131n, 5 mL nitrik asit \u00e7\u00f6z\u00fcm\u00fc (19) ekleyin, ayarlanabilir bir s\u0131cak plakaya yerle\u015ftirin ve \u00f6rne\u011fi \u00e7\u00f6zmek i\u00e7in 150 \u2103 'de \u0131s\u0131t\u0131n. \u00c7\u00f6z\u00fcm\u00fc so\u011futulay\u0131n, suyla 25 mL kolorimetrik t\u00fcpe aktar\u0131n ve i\u015faretlenmi\u015f hacme seyreltin. Ayn\u0131 anda bir reaktif bo\u015f testi yap\u0131n.<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">\u00d6rnek Test \u00c7\u00f6z\u00fcm\u00fcn\u00fcn Haz\u0131rlanmas\u0131<br class=\"container-utlnW2 wrapper-d0Cc1k undefined\" \/>5 mL orijinal \u00f6rnek \u00e7\u00f6z\u00fcm\u00fcn\u00fc 25 mL kolorimetrik t\u00fcp i\u00e7ine do\u011fru bir \u015fekilde pipet edin, 0,25 mL nitrik asit ekleyin, i\u015faretlenmi\u015f hacme deiyonla\u015ft\u0131r\u0131lm\u0131\u015f su ile seyreltin ve iyi sallay\u0131n. Bo\u015f bir test ayn\u0131 anda ger\u00e7ekle\u015ftirin - \u00f6rnek eklenmemesi d\u0131\u015f\u0131nda, bo\u015f test \u00e7\u00f6z\u00fcm\u00fcne eklenen reagentlerin t\u00fcr\u00fc ve miktar\u0131 test \u00e7\u00f6z\u00fcm\u00fcndekilerle ayn\u0131d\u0131r.<\/div>\n<\/li>\n<\/ol>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.1.2 Standart \u00c7\u00f6z\u00fcmlerin Haz\u0131rlanmas\u0131<\/h4>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Bak\u0131r Standart Serisinin Haz\u0131rlanmas\u0131:<br class=\"container-utlnW2 wrapper-d0Cc1k undefined\" \/>Pipet 0 \u03bcL, 25 \u03bcL, 50 \u03bcL, 100 \u03bcL ve 150 \u03bcL bak\u0131r standart \u00e7\u00f6z\u00fcm (1000 \u03bcg\/mL) s\u0131ras\u0131yla 100 mL hacimli \u015fi\u015felere. 1 mL nitrik asit ekleyin, i\u015faretlenmi\u015f hacme deiyonla\u015ft\u0131r\u0131lm\u0131\u015f su ile seyreltin ve iyi kar\u0131\u015ft\u0131r\u0131n. Bu standart serinin konsantrasyonlar\u0131 \u015funlard\u0131r: 0 \u03bcg\/mL, 0.25 \u03bcg\/mL, 0.50 \u03bcg\/mL, 1.00 \u03bcg\/mL ve 1.50 \u03bcg\/mL.<\/div>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.2 \u00d6rnek Testi<\/h3>\n<ol class=\"auto-hide-last-sibling-br\">\n<li>Test Ko\u015fullar\u0131<br class=\"container-utlnW2 wrapper-d0Cc1k undefined\" \/>Alev Atomik Emme Spektrofotometri Tespiti i\u00e7in Referans Ko\u015fullar\u0131<\/li>\n<\/ol>\n<p><br class=\"container-utlnW2 wrapper-d0Cc1k undefined\" \/><\/p>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-GhL7Lo\" data-scroll-inline-overflow=\"false\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"true\" data-scroll-inline-end-overflow=\"false\">\n<div class=\"table-scroll-container-hgHkfW mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Parametre<\/th>\n<th>\u00d6zellikler<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Dalga Uzunlu\u011fu<\/td>\n<td>324.7 nm'nin<\/td>\n<\/tr>\n<tr>\n<td>Spektral Bant Geni\u015fli\u011fi<\/td>\n<td>0,4 nm'lik<\/td>\n<\/tr>\n<tr>\n<td>Element Lamba Ak\u0131m\u0131<\/td>\n<td>3.0 mA'l\u0131k<\/td>\n<\/tr>\n<tr>\n<td>Yan\u0131c\u0131 Y\u00fcksekli\u011fi<\/td>\n<td>6 mm'lik<\/td>\n<\/tr>\n<tr>\n<td>Yak\u0131t Gaz\u0131 Ak\u0131\u015f H\u0131z\u0131<\/td>\n<td>1600 ml \/ dakika<\/td>\n<\/tr>\n<tr>\n<td>Hava Kompres\u00f6r\u00fc Bas\u0131nc\u0131<\/td>\n<td>0,22 MPa'n\u0131n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p><br class=\"container-utlnW2 wrapper-d0Cc1k undefined\" \/><\/p>\n<ol class=\"auto-hide-last-sibling-br\" start=\"2\">\n<li>\u00d6rnek testi<br class=\"container-utlnW2 wrapper-d0Cc1k undefined\" \/>Bak\u0131r standart seri \u00e7\u00f6z\u00fcmlerini alev atomizat\u00f6r\u00fcne y\u00fckselen konsantrasyon s\u0131ras\u0131nda tan\u0131t\u0131n ve emici de\u011ferlerini belirleyin. Standart seri \u00e7\u00f6z\u00fcmlerindeki bak\u0131r k\u00fctle konsantrasyonu absisa olarak ve ilgili emici de\u011ferleri ordinat olarak standart bir e\u011fri \u00e7izin.<\/li>\n<\/ol>\n<p><br class=\"container-utlnW2 wrapper-d0Cc1k undefined\" \/><\/p>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Standart \u00e7\u00f6z\u00fcmleri belirlemek i\u00e7in yap\u0131lanlarla ayn\u0131 deneysel ko\u015fullarda, s\u0131ras\u0131yla bo\u015f \u00e7\u00f6z\u00fcm ve \u00f6rnek test \u00e7\u00f6z\u00fcm\u00fcn\u00fc alev atomizat\u00f6r\u00fcne girin. Atomizasyondan sonra emici de\u011ferlerini belirleyin ve standart serilerle kar\u015f\u0131la\u015ft\u0131r\u0131larak miqdarl\u0131 \u00f6l\u00e7\u00fcm\u00fc ger\u00e7ekle\u015ftirin.<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>1. Method Overview After the sample is digested and treated, it is atomized by flame, and the absorbance is measured at a wavelength of 324.8 nm. Within a certain concentration range, the absorbance value of copper is proportional to its content, and quantification is performed by comparison with the standard series. 2. Instruments and Reagents [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[81,36],"tags":[],"class_list":["post-3916","post","type-post","status-publish","format-standard","hentry","category-petrochemical-and-chemical","category-applications"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/posts\/3916","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/comments?post=3916"}],"version-history":[{"count":0,"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/posts\/3916\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/media?parent=3916"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/categories?post=3916"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/tags?post=3916"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}