{"id":3894,"date":"2025-09-04T10:32:52","date_gmt":"2025-09-04T02:32:52","guid":{"rendered":"https:\/\/www.pgeneral.com\/?p=3894"},"modified":"2025-09-04T10:32:52","modified_gmt":"2025-09-04T02:32:52","slug":"determination-of-cadmium-in-surface-water-graphite-furnace-atomic-absorption-spectrometry","status":"publish","type":"post","link":"https:\/\/www.pgeneral.com\/tr\/applications\/determination-of-cadmium-in-surface-water-graphite-furnace-atomic-absorption-spectrometry","title":{"rendered":"Y\u00fczey Suyunda Kadmyumun Belirlenmesi (Grafit F\u0131r\u0131n\u0131 Atom Emme Spektrometrisi)"},"content":{"rendered":"<h2 class=\"header-vfC6AV auto-hide-last-sibling-br\">1. Y\u00f6ntem Genel Bak\u0131\u015f<\/h2>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Uygun tedavilerden sonra numune bir grafit t\u00fcp atomizat\u00f6r\u00fcne enjekte edilir. Numunede bulunan kadmium iyonlar\u0131 buharla\u015ft\u0131r\u0131l\u0131r ve grafit t\u00fcb\u00fcnde y\u00fcksek atomizasyon s\u0131cakl\u0131\u011f\u0131nda atomik buhara ayr\u0131l\u0131r. Belirlenecek eleman\u0131n temel durum atomlar\u0131, kadmium bo\u015f katot lambas\u0131 taraf\u0131ndan yay\u0131lan rezonans hatt\u0131n\u0131 emir. Belirli bir aral\u0131kta, emim yo\u011funlu\u011fu konsantrasyona orant\u0131l\u0131d\u0131r.<\/div>\n<div>\n<h2 class=\"header-vfC6AV auto-hide-last-sibling-br\">2. Aletler ve Reagentler<\/h2>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.1 Aletler ve Ekipmanlar<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.1.1 Test Aletleri<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-GhL7Lo\" data-scroll-inline-overflow=\"true\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"false\" data-scroll-inline-end-overflow=\"true\">\n<div class=\"table-scroll-container-hgHkfW mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Seri numaras\u0131.<\/th>\n<th>\u0130sim<\/th>\n<th>Miktar<\/th>\n<th>Teknik Gereksinimler<\/th>\n<th>Aksesuarlar<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Grafit F\u0131r\u0131n Atom Emme Spektrometresi<\/td>\n<td>1 set<\/td>\n<td>&#8211;<\/td>\n<td>Kadmyum Bo\u015f Katod Lambas\u0131<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>So\u011futma dola\u015f\u0131m su sistemi<\/td>\n<td>1 set<\/td>\n<td>Su pompas\u0131n\u0131n nominal ak\u0131\u015f h\u0131z\u0131: 3.5 L \/ dakika<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Argon Gaz\u0131<\/td>\n<td>1 silindir<\/td>\n<td>Safl\u0131k \u2265% 99,99<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.1.2 \u00d6rnek \u00d6n Tedavi Ekipmanlar\u0131<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-GhL7Lo\" data-scroll-inline-overflow=\"true\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"false\" data-scroll-inline-end-overflow=\"true\">\n<div class=\"table-scroll-container-hgHkfW mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Seri numaras\u0131.<\/th>\n<th>\u0130sim<\/th>\n<th>Miktar<\/th>\n<th>Teknik Gereksinimler<\/th>\n<th>Aksesuarlar<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>S\u0131cakl\u0131k Kontrollu S\u0131cak Plaka<\/td>\n<td>1 set<\/td>\n<td>Oda s\u0131cakl\u0131\u011f\u0131 ~ 300 \u2103<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Kolorimetrik T\u00fcp<\/td>\n<td>Birka\u00e7<\/td>\n<td>Hacim: 10 ml<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Mikropipet<\/td>\n<td>Her biri 1<\/td>\n<td>Aral\u0131klar\u0131: 20 \u03bcL ~ 200 \u03bcL, 1000 \u03bcL ~ 5000 \u03bcL<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>hacimli \u015fi\u015fe<\/td>\n<td>Birka\u00e7<\/td>\n<td>Hacimler: 100 mL, 1000 mL<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.2 Reagentler<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.2.1 Ham Reagentler<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-GhL7Lo\" data-scroll-inline-overflow=\"false\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"true\" data-scroll-inline-end-overflow=\"false\">\n<div class=\"table-scroll-container-hgHkfW mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Seri numaras\u0131.<\/th>\n<th>\u0130sim<\/th>\n<th>Teknik Gereksinimler<\/th>\n<th>Notlar<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Nitrik Asit<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.2 Haz\u0131rlanan Reagentler<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-GhL7Lo\" data-scroll-inline-overflow=\"false\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"true\" data-scroll-inline-end-overflow=\"false\">\n<div class=\"table-scroll-container-hgHkfW mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Seri numaras\u0131.<\/th>\n<th>\u0130sim<\/th>\n<th>Haz\u0131rlama Y\u00f6ntemi<\/th>\n<th>Notlar<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Nitrik Asit \u00c7\u00f6z\u00fcm\u00fc (1 99)<\/td>\n<td>10 mL nitrik asit \u00f6l\u00e7\u00fcn, k\u00fc\u00e7\u00fck miktarda su i\u00e7eren 1000 mL hacimli bir kolba ekleyin ve i\u015faretlenmi\u015f hacime su ile seyredin.<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.3 Referans Standartlar\u0131<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.3.1 Stok \u00c7\u00f6z\u00fcm\u00fc<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-GhL7Lo\" data-scroll-inline-overflow=\"true\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"false\" data-scroll-inline-end-overflow=\"true\">\n<div class=\"table-scroll-container-hgHkfW mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Seri numaras\u0131.<\/th>\n<th>- Hay\u0131r. - Hay\u0131r.<\/th>\n<th>\u0130sim<\/th>\n<th>Teknik Gereksinimler<\/th>\n<th>Notlar<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>GSB G 62040-90'\u0131<\/td>\n<td>Kadmyum Standart \u00c7\u00f6z\u00fcm<\/td>\n<td>Konsantrasyon: 1000 mg \/ L<\/td>\n<td>Merkez Demir ve \u00c7elik Ara\u015ft\u0131rma Enstit\u00fcs\u00fc<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h2 class=\"header-vfC6AV auto-hide-last-sibling-br\">3. Operasyon Prosed\u00fcr\u00fc<\/h2>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.1 \u00d6rnek Haz\u0131rlama<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.1.1 Test \u00c7\u00f6z\u00fcm\u00fcn\u00fcn Haz\u0131rlanmas\u0131<\/h4>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Temiz su \u00f6rnekleri do\u011frudan belirlenebilir. Y\u00fcksek s\u00fcspansiyon kat\u0131 maddelere sahip su \u00f6rnekleri i\u00e7in, analizden \u00f6nce organik maddelerin asitle\u015fmesi ve sindirimi gereklidir.<\/div>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.1.2 Standart \u00c7\u00f6z\u00fcmlerin Haz\u0131rlanmas\u0131<\/h4>\n<ol class=\"auto-hide-last-sibling-br\">\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Kadmiyum Standart Ara \u00c7\u00f6z\u00fcm\u00fcn\u00fcn Haz\u0131rlanmas\u0131 (50 \u03bcg\/mL): Kadmiyum standart stok \u00e7\u00f6z\u00fcm\u00fcn\u00fcn (1000 \u03bcg\/mL) 5,0 mL'sini 100 mL hacimli bir kolba do\u011fru bir \u015fekilde pipet edin, (1 99) nitrik asit \u00e7\u00f6z\u00fcm\u00fc ile i\u015faretlenmi\u015f hacime seyreltin ve iyi sallay\u0131n.<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Kadmiyum Standart Ara \u00c7\u00f6z\u00fcm\u00fcn\u00fcn Haz\u0131rlanmas\u0131 (1,0 \u03bcg\/mL): Kadmiyum Standart Ara \u00c7\u00f6z\u00fcm\u00fcn\u00fcn (50 \u03bcg\/mL) 2,0 mL'sini 100 mL hacimli bir kolba do\u011fru bir \u015fekilde pipet edin, (1 99) nitrik asit \u00e7\u00f6z\u00fcm\u00fc ile i\u015faretlenmi\u015f hacime seyreltin ve iyi sallay\u0131n.<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Kadmiyum Standart \u00c7al\u0131\u015fma \u00c7\u00f6z\u00fcm\u00fcn\u00fcn Haz\u0131rlanmas\u0131 (100 ng\/mL): Kadmiyum standart \u00e7\u00f6z\u00fcm\u00fcn\u00fcn 10,0 mL'sini (1,0 \u03bcg\/mL) 100 mL hacimli bir kolba do\u011fru bir \u015fekilde pipet edin, (1 99) nitrik asit \u00e7\u00f6z\u00fcm\u00fc ile i\u015faretlenmi\u015f hacime seyreltin ve iyi sallay\u0131n.<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Kadmiyum Standart Serisinin Haz\u0131rlanmas\u0131: Kadmiyum standart \u00e7al\u0131\u015fma \u00e7\u00f6z\u00fcm\u00fcn\u00fcn 0,0 mL, 0,50 mL, 1,00 mL, 3,00 mL, 5,00 mL ve 7,00 mL'sini s\u0131ras\u0131yla ayr\u0131 100 mL hacimli \u015fi\u015felere pipet edin.  (99) nitrik asit \u00e7\u00f6z\u00fcm\u00fc ile i\u015faretlenmi\u015f hacime seyreltin ve iyi sallay\u0131n. Bu, 0.00 ng\/mL, 0.5 ng\/mL, 1.00 ng\/mL, 3.00 ng\/mL, 5.00 ng\/mL ve 7.00 ng\/mL kadmiyum konsantrasyonlar\u0131na sahip standart bir seri ile sonu\u00e7lan\u0131r.<\/div>\n<\/li>\n<\/ol>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.2 \u00d6rnek Testi<\/h3>\n<ol class=\"auto-hide-last-sibling-br\">\n<li>Test Ko\u015fullar\u0131 Atomik emim spektrofotometri i\u00e7in referans test ko\u015fullar\u0131: | Parametre | \u00d6zellikler | | &#8212;  | &#8212;  | | Dalga boyu (nm) | 228.8 | | Spektral Bant Geni\u015fli\u011fi (nm) | 0.4 | | Element Lamba Ak\u0131m\u0131 (mA) | 2.0 | | Arka plan d\u00fczeltme y\u00f6ntemi | Deuterium Lamba Arka plan d\u00fczeltme | | Enjeksiyon hacmi (\u03bcL) | 15 |<\/li>\n<\/ol>\n<p><br class=\"container-utlnW2 wrapper-d0Cc1k undefined\" \/><\/p>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\"><strong>Grafit F\u0131r\u0131n Is\u0131tma Program\u0131<\/strong><\/div>\n<p><br class=\"container-utlnW2 wrapper-d0Cc1k undefined\" \/><\/p>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-GhL7Lo\" data-scroll-inline-overflow=\"false\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"true\" data-scroll-inline-end-overflow=\"false\">\n<div class=\"table-scroll-container-hgHkfW mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Ad\u0131m<\/th>\n<th>S\u0131cakl\u0131k (\u2103)<\/th>\n<th>Is\u0131tma S\u00fcresi (S)<\/th>\n<th>Tutma S\u00fcresi (S)<\/th>\n<th>\u0130\u00e7 Gaz Ak\u0131\u015f\u0131<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>110<\/td>\n<td>10<\/td>\n<td>10<\/td>\n<td>Y\u00fcksek<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>350<\/td>\n<td>10<\/td>\n<td>10<\/td>\n<td>Y\u00fcksek<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>1700<\/td>\n<td>0<\/td>\n<td>3<\/td>\n<td>Kapal\u0131<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>1900<\/td>\n<td>1<\/td>\n<td>2<\/td>\n<td>Y\u00fcksek<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p><br class=\"container-utlnW2 wrapper-d0Cc1k undefined\" \/><\/p>\n<ol class=\"auto-hide-last-sibling-br\" start=\"2\">\n<li>\u00d6rnek Testi Reagent bo\u015flu\u011funu, standart seriyi ve \u00f6rnek \u00e7\u00f6z\u00fcm\u00fcn\u00fc ard\u0131c\u0131l olarak pipetleyin, grafit t\u00fcb\u00fcne enjekte edin ve emicilerini belirleyin. S\u0131f\u0131r standart \u00e7\u00f6z\u00fcm\u00fcn emilimini her standart \u00e7\u00f6z\u00fcm\u00fcn emiliminden \u00e7\u0131kar\u0131n. Konsantrasyonu absisa olarak ve ilgili emici ordinat olarak bir \u00e7al\u0131\u015fma e\u011frisi \u00e7izin. Test \u00e7\u00f6z\u00fcm\u00fcn\u00fcn \u00f6l\u00e7\u00fclen emilmesine dayanarak, \u00e7al\u0131\u015fma e\u011frisinden kadmium k\u00fctle konsantrasyonunu bulun.<\/li>\n<\/ol>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.3 Sonu\u00e7 Hesaplamas\u0131<\/h3>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Su \u00f6rne\u011findeki kadmium konsantrasyonu a\u015fa\u011f\u0131daki form\u00fcl\u00fc kullanarak hesaplan\u0131r:<\/div>\n<div><img decoding=\"async\" class=\"alignnone  wp-image-3895\" src=\"http:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/09\/333.png\" alt=\"\" width=\"167\" height=\"76\" srcset=\"https:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/09\/333.png 204w, https:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/09\/333-18x8.png 18w\" sizes=\"(max-width: 167px) 100vw, 167px\" \/><\/div>\n<p><br class=\"container-utlnW2 wrapper-d0Cc1k undefined\" \/><\/p>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Nerede:<\/div>\n<ul class=\"auto-hide-last-sibling-br\">\n<li><span class=\"container-rkuXQi math-inline\" data-custom-copy-text=\"\\(\u03c1(Cd)=\\frac{\u03c1_{1} \u00d7 V_{1}}{V}\\)\">\u03c1(Cd)<\/span> = Su \u00f6rne\u011findeki kadmiyum k\u00fctle konsantrasyonu, birim: litre ba\u015f\u0131na mikrogram (\u03bcg\/L);<\/li>\n<li><span class=\"container-rkuXQi math-inline\" data-custom-copy-text=\"\\(\u03c1(Cd)=\\frac{\u03c1_{1} \u00d7 V_{1}}{V}\\)\">\u03c11<\/span>\u00a0= Kalibrasyon e\u011frisinden elde edilen \u00f6rnekteki kadmium konsantrasyonu, birim: litre ba\u015f\u0131na mikrogram (\u03bcg\/L);<\/li>\n<li><span class=\"container-rkuXQi math-inline\" data-custom-copy-text=\"\\(V_{1}\\)\">V1'in<\/span>\u00a0= Belirleme i\u00e7in kullan\u0131lan \u00f6rne\u011fin hacmi, birim: mililitre (mL);<\/li>\n<li><span class=\"container-rkuXQi math-inline single-Z69glH\" data-custom-copy-text=\"V\">V'nin<\/span>\u00a0= Al\u0131nan su \u00f6rne\u011finin hacmi, birim: mililitre (mL).<\/li>\n<\/ul>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>1. Method Overview After appropriate treatment, the sample is injected into a graphite tube atomizer. The cadmium ions contained in the sample are evaporated and dissociated into atomic vapor at high atomization temperature in the graphite tube. The ground-state atoms of the element to be determined absorb the resonance line emitted by the cadmium hollow [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[36,75],"tags":[],"class_list":["post-3894","post","type-post","status-publish","format-standard","hentry","category-applications","category-environment"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/posts\/3894","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/comments?post=3894"}],"version-history":[{"count":0,"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/posts\/3894\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/media?parent=3894"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/categories?post=3894"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/tags?post=3894"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}