{"id":3891,"date":"2025-09-04T10:26:07","date_gmt":"2025-09-04T02:26:07","guid":{"rendered":"https:\/\/www.pgeneral.com\/?p=3891"},"modified":"2025-09-04T10:26:07","modified_gmt":"2025-09-04T02:26:07","slug":"determination-of-magnesium-in-sodium-bicarbonate-flame-atomic-absorption-spectrometry","status":"publish","type":"post","link":"https:\/\/www.pgeneral.com\/tr\/applications\/determination-of-magnesium-in-sodium-bicarbonate-flame-atomic-absorption-spectrometry","title":{"rendered":"Sodyum Bikarbonatta Magnezyumun Belirlenmesi (Alev Atom Emme Spektrometrisi)"},"content":{"rendered":"<h2 class=\"header-vfC6AV auto-hide-last-sibling-br\">1. Y\u00f6ntem Genel Bak\u0131\u015f<\/h2>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">\u00d6rnek sindirildikten ve alev taraf\u0131ndan atomla\u015ft\u0131r\u0131ld\u0131ktan sonra, emici 285,2 nm dalga boyunda \u00f6l\u00e7\u00fcl\u00fcr. Belirli bir konsantrasyon aral\u0131\u011f\u0131nda, magnezyumun emici de\u011feri i\u00e7eri\u011fine orant\u0131l\u0131d\u0131r ve miqdarl\u0131k standart bir seriyle kar\u015f\u0131la\u015ft\u0131r\u0131larak ger\u00e7ekle\u015ftirilir.<\/div>\n<div>\n<h2 class=\"header-vfC6AV auto-hide-last-sibling-br\">2. Aletler ve Reagentler<\/h2>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.1 Aletler ve Ekipmanlar<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.1.1 Test Aletleri<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-GhL7Lo\" data-scroll-inline-overflow=\"true\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"false\" data-scroll-inline-end-overflow=\"true\">\n<div class=\"table-scroll-container-hgHkfW mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Seri numaras\u0131.<\/th>\n<th>\u0130sim<\/th>\n<th>Miktar<\/th>\n<th>Teknik Gereksinimler<\/th>\n<th>Aksesuarlar<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Alev Atom Emme Spektrofotometri<\/td>\n<td>1 set<\/td>\n<td>\/<\/td>\n<td>Magnezyum Bo\u015f Katod Lambas\u0131<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Asetilen Gaz\u0131<\/td>\n<td>1 silindir<\/td>\n<td>Safl\u0131k \u2265% 99,99<\/td>\n<td>\/<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Hava Kompres\u00f6r\u00fc<\/td>\n<td>1 set<\/td>\n<td>Nominal bo\u015faltma bas\u0131nc\u0131: 0.3 MPa<\/td>\n<td>\/<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.1.2 \u00d6rnek \u00d6n Tedavi Ekipmanlar\u0131<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-GhL7Lo\" data-scroll-inline-overflow=\"true\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"false\" data-scroll-inline-end-overflow=\"true\">\n<div class=\"table-scroll-container-hgHkfW mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Seri numaras\u0131.<\/th>\n<th>\u0130sim<\/th>\n<th>Miktar<\/th>\n<th>Teknik Gereksinimler<\/th>\n<th>Aksesuarlar<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Mikrodalga Sindirim Sistemi<\/td>\n<td>1 set<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>S\u0131cakl\u0131k Kontrollu S\u0131cak Plaka<\/td>\n<td>1 set<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Elektronik Denge<\/td>\n<td>1 set<\/td>\n<td>Hassasiyet: 0.1 mg<\/td>\n<td>\/<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>Ultrasaf Su Sistemi<\/td>\n<td>1 set<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>Mikropipet<\/td>\n<td>Her biri 1<\/td>\n<td>Aral\u0131klar\u0131: 20 \u03bcL ~ 200 \u03bcL, 100 \u03bcL ~ 1000 \u03bcL<\/td>\n<td>\/<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>hacimli \u015fi\u015fe<\/td>\n<td>Birka\u00e7<\/td>\n<td>Hacim: 100 ml<\/td>\n<td>\/<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>Kolorimetrik T\u00fcp<\/td>\n<td>Birka\u00e7<\/td>\n<td>Hacim: 25 ml<\/td>\n<td>\/<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.2 Reagentler<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.2.1 Ham Reagentler<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-GhL7Lo\" data-scroll-inline-overflow=\"false\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"true\" data-scroll-inline-end-overflow=\"false\">\n<div class=\"table-scroll-container-hgHkfW mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Seri numaras\u0131.<\/th>\n<th>\u0130sim<\/th>\n<th>Teknik Gereksinimler<\/th>\n<th>Notlar<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Nitrik Asit<\/td>\n<td>MOS S\u0131n\u0131f\u0131<\/td>\n<td>\/<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Hidroklorik Asit<\/td>\n<td>Garantili Reagent (GR)<\/td>\n<td>\/<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.2 Haz\u0131rlanan Reagentler<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-GhL7Lo\" data-scroll-inline-overflow=\"false\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"true\" data-scroll-inline-end-overflow=\"false\">\n<div class=\"table-scroll-container-hgHkfW mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Seri numaras\u0131.<\/th>\n<th>\u0130sim<\/th>\n<th>Haz\u0131rlama Y\u00f6ntemi<\/th>\n<th>Notlar<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Nitrik Asit \u00c7\u00f6z\u00fcm\u00fc (5 95)<\/td>\n<td>50 mL nitrik asit \u00f6l\u00e7\u00fcn, yava\u015f yava\u015f 950 mL deiyonla\u015ft\u0131r\u0131lm\u0131\u015f suya ekleyin ve iyi kar\u0131\u015ft\u0131r\u0131n.<\/td>\n<td>\/<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.3 Referans Standartlar\u0131<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.3.1 Stok \u00c7\u00f6z\u00fcm\u00fc<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-GhL7Lo\" data-scroll-inline-overflow=\"true\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"false\" data-scroll-inline-end-overflow=\"true\">\n<div class=\"table-scroll-container-hgHkfW mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Seri numaras\u0131.<\/th>\n<th>- Hay\u0131r. - Hay\u0131r.<\/th>\n<th>\u0130sim<\/th>\n<th>Teknik Gereksinimler<\/th>\n<th>Notlar<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>GBW (E) 080126<\/td>\n<td>Magnezyum Tek Elemanl\u0131 Standart \u00c7\u00f6z\u00fcm<\/td>\n<td>Konsantrasyon: 1000 \u03bcg \/ mL<\/td>\n<td>Ulusal Metroloji Enstit\u00fcs\u00fc, \u00c7in<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h2 class=\"header-vfC6AV auto-hide-last-sibling-br\">3. Operasyon Prosed\u00fcr\u00fc<\/h2>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.1 \u00d6rnek Haz\u0131rlama<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.1.1 Test \u00c7\u00f6z\u00fcm\u00fcn\u00fcn Haz\u0131rlanmas\u0131<\/h4>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">0,5 g sodyum bikarbonat \u00f6rne\u011fini (hassasiyeti 0,001 g) mikrodalga sindirim kap\u0131na do\u011fru bir \u015fekilde a\u011f\u0131rlay\u0131n, 8 mL nitrik asit ekleyin ve \u00f6rne\u011fi mikrodalga sindirim sisteminin \u00e7al\u0131\u015fma prosed\u00fcrlerine g\u00f6re sindirin. So\u011futuktan sonra sindirim damar\u0131n\u0131 \u00e7\u0131kar\u0131n ve asiti 140 \u2103 ~ 160 \u2103 s\u0131cak bir plakada buharla\u015ft\u0131r\u0131n hacim 0,5 mL ~ 1 mL'ye d\u00fc\u015fene kadar. Sindirim damar\u0131 so\u011futuktan sonra sindirilmi\u015f \u00e7\u00f6z\u00fcm\u00fc 25 mL kolorimetrik t\u00fcbe aktar\u0131n. Sindirim damar\u0131n\u0131 k\u00fc\u00e7\u00fck miktarda su ile 2 ~ 3 kez y\u0131kay\u0131n, y\u0131kama \u00e7\u00f6z\u00fcmlerini kolorimetrik t\u00fcp i\u00e7ine birle\u015ftirin, i\u015faretlenmi\u015f hacime su ile seyreltin ve sonraki kullan\u0131m i\u00e7in iyi kar\u0131\u015ft\u0131r\u0131n. Ayn\u0131 anda bir reaktif bo\u015f haz\u0131rlay\u0131n.<\/div>\n<p>&nbsp;<\/p>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\"><strong>Mikrodalga Sindirim Program\u0131<\/strong><\/div>\n<p>&nbsp;<\/p>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-GhL7Lo\" data-scroll-inline-overflow=\"false\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"true\" data-scroll-inline-end-overflow=\"false\">\n<div class=\"table-scroll-container-hgHkfW mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Ad\u0131m<\/th>\n<th>S\u0131cakl\u0131k \/ \u2103<\/th>\n<th>Tutma S\u00fcresi \/ dakika<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>100<\/td>\n<td>3<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>120<\/td>\n<td>3<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>140<\/td>\n<td>3<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>160<\/td>\n<td>3<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>180<\/td>\n<td>30<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.1.2 Standart \u00c7\u00f6z\u00fcmlerin Haz\u0131rlanmas\u0131<\/h4>\n<ol class=\"auto-hide-last-sibling-br\">\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Magnezyum Standart Ara \u00c7\u00f6z\u00fcm\u00fcn\u00fcn Haz\u0131rlanmas\u0131 (100 \u03bcg\/mL): 10,0 mL magnezyum standart stok \u00e7\u00f6z\u00fcm\u00fcn\u00fc (1000 \u03bcg\/mL) 100 mL hacimli bir kolba do\u011fru bir \u015fekilde pipet edin, (5 95) nitrik asit \u00e7\u00f6z\u00fcm\u00fc ile i\u015faretlenmi\u015f hacime seyreltin ve iyi sallay\u0131n.<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Magnezyum Standart Serisinin Haz\u0131rlanmas\u0131: S\u0131ras\u0131yla ayr\u0131 100 mL hacimli \u015fi\u015felere 0,0, 0,1, 0,2, 0,3 ve 0,4 mL magnezyum standart ara \u00e7\u00f6z\u00fcm\u00fcn\u00fc (100 \u03bcg\/mL) do\u011fru bir \u015fekilde pipetleyin.  (5 95) nitrik asit \u00e7\u00f6z\u00fcm\u00fc ile i\u015faretlenmi\u015f hacime seyreltin ve iyi kar\u0131\u015ft\u0131r\u0131n. Bu standart serinin konsantrasyonlar\u0131 0,0, 0,1, 0,2, 0,3 ve 0,4 \u03bcg\/mL'dir.<\/div>\n<\/li>\n<\/ol>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.2 \u00d6rnek Testi<\/h3>\n<ol class=\"auto-hide-last-sibling-br\">\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Test Ko\u015fullar\u0131 Alev atomik emim spektrofotometri i\u00e7in referans test ko\u015fullar\u0131: | Parametre | \u00d6zellikler (Magnezyum) | | &#8212;  | &#8212;  | | Dalga Boyu (nm) | 285.2 | | Spektral Bant Geni\u015fli\u011fi (nm) | 0.2 | | Element Lamba Ak\u0131m\u0131 (mA) | 3.0 | | Burner Y\u00fcksekli\u011fi (mm) | 6 | | Yak\u0131t Gaz\u0131 Ak\u0131\u015f H\u0131z\u0131 (mL \/ dakika) | 1500 | | Hava Kompres\u00f6r\u00fc Bas\u0131nc\u0131 (MPa) | 0.22 | | Arka Plan\u0131 D\u00fczeltme Y\u00f6ntemi | Hi\u00e7biri |<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">\u00d6rnek Testi Aleti optimal \u00e7al\u0131\u015fma durumuna ayarlay\u0131n, alevi yakalay\u0131n ve yak\u0131t gaz\u0131 ak\u0131\u015f\u0131n\u0131 ayarlay\u0131n. Standart \u00e7\u00f6z\u00fcmleri ve \u00f6rnek \u00e7\u00f6z\u00fcmlerini s\u0131ras\u0131yla test edin, verileri okuyun, \u00f6rnek a\u011f\u0131rl\u0131\u011f\u0131n\u0131 girin ve sonu\u00e7lar\u0131 kontrol edin ve kaydedin.<\/div>\n<\/li>\n<\/ol>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.3 Sonu\u00e7 Hesaplamas\u0131<\/h3>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Numunedeki magnezyum i\u00e7eri\u011fi a\u015fa\u011f\u0131daki form\u00fcl\u00fc kullanarak hesaplan\u0131r:<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div><\/div>\n<div><img decoding=\"async\" class=\"alignnone  wp-image-3892\" src=\"http:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/09\/222.png\" alt=\"\" width=\"194\" height=\"59\" srcset=\"https:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/09\/222.png 263w, https:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/09\/222-18x5.png 18w\" sizes=\"(max-width: 194px) 100vw, 194px\" \/><\/div>\n<div><\/div>\n<div>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-GhL7Lo\" data-scroll-inline-overflow=\"true\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"false\" data-scroll-inline-end-overflow=\"true\">\n<div class=\"table-scroll-container-hgHkfW mdbox-table-scroll-container\">\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Nerede:<\/div>\n<ul class=\"auto-hide-last-sibling-br\">\n<li><span class=\"container-rkuXQi math-inline single-Z69glH\" data-custom-copy-text=\"X\">X<\/span>\u00a0= \u00d6rnekte magnezyum i\u00e7eri\u011fi, birim: kilogram ba\u015f\u0131na miligram (mg\/kg);<\/li>\n<li><span class=\"container-rkuXQi math-inline\" data-custom-copy-text=\"\\(\\rho\\)\">\u03c1<\/span>\u00a0= \u00d6rnek test \u00e7\u00f6z\u00fcm\u00fcnde magnezyum k\u00fctle konsantrasyonu, birim: litre ba\u015f\u0131na miligram (mg \/ L);<\/li>\n<li><span class=\"container-rkuXQi math-inline\" data-custom-copy-text=\"\\(\\rho_{0}\\)\">\u03c10<\/span>\u00a0= Bo\u015f \u00e7\u00f6z\u00fcmdeki magnezyum k\u00fctle konsantrasyonu, birim: litre ba\u015f\u0131na miligram (mg \/ L);<\/li>\n<li><span class=\"container-rkuXQi math-inline single-Z69glH\" data-custom-copy-text=\"f\">F<\/span>\u00a0= sindirilmi\u015f \u00f6rnek \u00e7\u00f6z\u00fcm\u00fcn\u00fcn seyreltme fakt\u00f6r\u00fc;<\/li>\n<li><span class=\"container-rkuXQi math-inline single-Z69glH\" data-custom-copy-text=\"V\">V'nin<\/span>\u00a0= Sindirilen \u00f6rnek \u00e7\u00f6z\u00fcm\u00fcn\u00fcn toplam hacmi, birim: mililitre (mL);<\/li>\n<li><span class=\"container-rkuXQi math-inline single-Z69glH\" data-custom-copy-text=\"m\">M<\/span>\u00a0= \u00d6rne\u011fin k\u00fctlesi, birim: gram (g).<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>1. Method Overview After the sample is digested and atomized by flame, the absorbance is measured at a wavelength of 285.2 nm. Within a certain concentration range, the absorbance value of magnesium is proportional to its content, and quantification is performed by comparison with a standard series. 2. Instruments and Reagents 2.1 Instruments and Equipment [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[81,36],"tags":[],"class_list":["post-3891","post","type-post","status-publish","format-standard","hentry","category-petrochemical-and-chemical","category-applications"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/posts\/3891","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/comments?post=3891"}],"version-history":[{"count":0,"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/posts\/3891\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/media?parent=3891"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/categories?post=3891"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pgeneral.com\/tr\/wp-json\/wp\/v2\/tags?post=3891"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}