{"id":3790,"date":"2025-07-28T16:03:51","date_gmt":"2025-07-28T08:03:51","guid":{"rendered":"https:\/\/www.pgeneral.com\/?p=3790"},"modified":"2025-07-28T16:03:51","modified_gmt":"2025-07-28T08:03:51","slug":"determination-of-lead-in-drinking-water-graphite-furnace-atomic-absorption-spectrometry","status":"publish","type":"post","link":"https:\/\/www.pgeneral.com\/pt\/applications\/determination-of-lead-in-drinking-water-graphite-furnace-atomic-absorption-spectrometry","title":{"rendered":"Determina\u00e7\u00e3o do chumbo na \u00e1gua pot\u00e1vel (espectrometria de absor\u00e7\u00e3o at\u00f4mica do forno de grafito)"},"content":{"rendered":"<h2 class=\"header-vfC6AV auto-hide-last-sibling-br\">1. Vista geral do m\u00e9todo<\/h2>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Ap\u00f3s tratamento adequado, a amostra \u00e9 atomizada em um forno de grafito, e a absorb\u00eancia \u00e9 medida a 283,3 nm. Dentro de uma certa gama de concentra\u00e7\u00f5es, a absorp\u00e7\u00e3o do chumbo \u00e9 proporcional ao seu conte\u00fado, e a quantifica\u00e7\u00e3o \u00e9 realizada em compara\u00e7\u00e3o com uma s\u00e9rie padr\u00e3o.<\/div>\n<div>\n<h2 class=\"header-vfC6AV auto-hide-last-sibling-br\">2. Instrumentos e Reagentes<\/h2>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.1 Instrumentos e equipamento<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.1.1 Instrumentos de ensaio<\/h4>\n<div class=\"auto-hide-last-sibling-br table-container-GhL7Lo\">\n<table>\n<thead>\n<tr>\n<th>Nome<\/th>\n<th>Quantidade<\/th>\n<th>Requisitos T\u00e9cnicos<\/th>\n<th>Acess\u00f3rios<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Micropipeta<\/td>\n<td>1 cada<\/td>\n<td>100 \u03bcL~1000 \u03bcL, 1000 \u03bcL~5000 \u03bcL, 5~50 \u03bcL<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Flaco volum\u00e9trico<\/td>\n<td>V\u00e1rios<\/td>\n<td>100 ml<\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.1.2 Equipamento de pr\u00e9-tratamento<\/h4>\n<div class=\"auto-hide-last-sibling-br table-container-GhL7Lo\">\n<table>\n<thead>\n<tr>\n<th>Serie No.<\/th>\n<th>Nome<\/th>\n<th>Quantidade<\/th>\n<th>Requisitos T\u00e9cnicos<\/th>\n<th>Acess\u00f3rios<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Micropipeta<\/td>\n<td>1 cada<\/td>\n<td>100 \u03bcL~1000 \u03bcL, 1000 \u03bcL~5000 \u03bcL, 5~50 \u03bcL<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Flaco volum\u00e9trico<\/td>\n<td>V\u00e1rios<\/td>\n<td>100 ml<\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.2 Reagentes<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.2.1 Reagentes<\/h4>\n<div class=\"auto-hide-last-sibling-br table-container-GhL7Lo\">\n<table>\n<thead>\n<tr>\n<th>Serie No.<\/th>\n<th>Nome<\/th>\n<th>Requisitos T\u00e9cnicos<\/th>\n<th>Observa\u00e7\u00f5es<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>\u00c1cido n\u00edtrico<\/td>\n<td>Grado MOS<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.3 Normas de refer\u00eancia<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.3.1 Solu\u00e7\u00f5es de a\u00e7\u00f5es<\/h4>\n<div class=\"auto-hide-last-sibling-br table-container-GhL7Lo\">\n<table>\n<thead>\n<tr>\n<th>Serie No.<\/th>\n<th>N\u00e3o.<\/th>\n<th>Nome<\/th>\n<th>Requisitos T\u00e9cnicos<\/th>\n<th>Observa\u00e7\u00f5es<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>08619 GBW<\/td>\n<td>Subst\u00e2ncia padr\u00e3o de solu\u00e7\u00e3o de um \u00fanico elemento de chumbo<\/td>\n<td>1000 \u03bcg\/ml<\/td>\n<td>Instituto Nacional de Metrologia, China<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2 class=\"header-vfC6AV auto-hide-last-sibling-br\">3. Procedimentos operacionais<\/h2>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.1 Processo de amostras<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.1.1 Prepara\u00e7\u00e3o da Solu\u00e7\u00e3o de Testes<\/h4>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Pegue 100 ml de amostra de \u00e1gua em um flask volum\u00e9trico, adiciona 0,5 ml de \u00e1cido n\u00edtrico e mistura bem. Faz um teste em branco ao lado da amostra.<\/div>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.1.2 Prepara\u00e7\u00e3o de solu\u00e7\u00f5es padr\u00e3o<\/h4>\n<ol class=\"auto-hide-last-sibling-br\">\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Prepara\u00e7\u00e3o de solu\u00e7\u00e3o intermedi\u00e1ria padr\u00e3o de chumbo: Solu\u00e7\u00e3o padr\u00e3o de chumbo (1,0 \u03bcg\/mL): Pipeta precisamente 0,1 mL de solu\u00e7\u00e3o padr\u00e3o de chumbo (1000 \u03bcg\/mL) em um flask volum\u00e9trico de 100 mL, adiciona 0,5 mL de solu\u00e7\u00e3o de \u00e1cido n\u00edtrico, dilui para a marca e agite bem.<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Prepara\u00e7\u00e3o da s\u00e9rie padr\u00e3o de chumbo: Exatamente pipeta 0,0, 0,1, 0,2, 0,3 e 0,4 ml de solu\u00e7\u00e3o padr\u00e3o de chumbo (1,0 \u03bcg\/ml) em flasks volum\u00e9tricos de 10 ml respectivamente. Adicionar 0,5 ml de solu\u00e7\u00e3o de \u00e1cido n\u00edtrico a cada um, diluir para a marca, e obter solu\u00e7\u00f5es de s\u00e9rie padr\u00e3o de chumbo com concentra\u00e7\u00f5es de 0,0, 10,0, 20,0, 30,0 e 40,0 ng\/ml.<\/div>\n<\/li>\n<\/ol>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.2 Ensaios de amostras<\/h3>\n<ol class=\"auto-hide-last-sibling-br\">\n<li>Condi\u00e7\u00f5es de ensaio Condi\u00e7\u00f5es de refer\u00eancia para detec\u00e7\u00e3o de espectrofotom\u00e9tro de absor\u00e7\u00e3o at\u00f4mica do forno de grafito<\/li>\n<\/ol>\n<div class=\"auto-hide-last-sibling-br table-container-GhL7Lo\">\n<table>\n<thead>\n<tr>\n<th>Elemento<\/th>\n<th>Chumbo<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Longitude de onda (nm)<\/td>\n<td>283.3<\/td>\n<\/tr>\n<tr>\n<td>Largura de banda espectral (nm)<\/td>\n<td>0.4<\/td>\n<\/tr>\n<tr>\n<td>Corrente de l\u00e2mpada de elementos (mA)<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>M\u00e9todo de corre\u00e7\u00e3o de fundo<\/td>\n<td>Lampa de deut\u00e9rio<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<\/div>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\"><strong>Programa de aquecimento de Furno de Graf\u00edto<\/strong><\/div>\n<p>&nbsp;<\/p>\n<div class=\"auto-hide-last-sibling-br table-container-GhL7Lo\">\n<table>\n<thead>\n<tr>\n<th>Passo<\/th>\n<th>Procedimento<\/th>\n<th>Temperatura ([UNK])<\/th>\n<th>Hora de Rampa (s)<\/th>\n<th>Hold Time (s)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Seco<\/td>\n<td>120<\/td>\n<td>10<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Cenada<\/td>\n<td>450<\/td>\n<td>10<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Atomiza\u00e7\u00e3o<\/td>\n<td>1800<\/td>\n<td>0<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>Limpar<\/td>\n<td>1900<\/td>\n<td>1<\/td>\n<td>2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<ol class=\"auto-hide-last-sibling-br\" start=\"2\">\n<li>Teste de amostras Determine a absor\u00e7\u00e3o de solu\u00e7\u00f5es padr\u00e3o, solu\u00e7\u00f5es de teste em branco e solu\u00e7\u00f5es de teste em sequ\u00eancia. subtrair a absorb\u00eancia da solu\u00e7\u00e3o padr\u00e3o zero da absorb\u00eancia de cada solu\u00e7\u00e3o padr\u00e3o. Plote uma curva de trabalho com concentra\u00e7\u00e3o de mass a como a abscissa e a absorb\u00eancia correspondente como a ordenada. Baseado na absorb\u00eancia medida da solu\u00e7\u00e3o de ensaio, encontrar a concentra\u00e7\u00e3o de massa de chumbo da curva de trabalho.<\/li>\n<\/ol>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.3 Calcula\u00e7\u00e3o dos resultados<\/h3>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">F\u00f3rmula:<\/div>\n<p><img decoding=\"async\" class=\"alignnone  wp-image-3791\" src=\"http:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/07\/2222\u5fae\u4fe1\u56fe\u7247_20250728160213_3807-300x128.png\" alt=\"\" width=\"199\" height=\"85\" srcset=\"https:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/07\/2222\u5fae\u4fe1\u56fe\u7247_20250728160213_3807-300x129.png 300w, https:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/07\/2222\u5fae\u4fe1\u56fe\u7247_20250728160213_3807-18x8.png 18w, https:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/07\/2222\u5fae\u4fe1\u56fe\u7247_20250728160213_3807.png 303w\" sizes=\"(max-width: 199px) 100vw, 199px\" \/><\/p>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Onde:<\/div>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">\u03c1\u2014\u2014 Concentra\u00e7\u00e3o de massa de chumbo na amostra de \u00e1gua, em miligramos por litro (mg\/L);<\/div>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\"><span class=\"container-rkuXQi math-inline\" data-custom-copy-text=\"\\(\\rho_1\\)\">\u03c11<\/span>\u2014 \u2014 Concentra\u00e7\u00e3o de massa de chumbo na amostra de \u00e1gua obtida na curva padr\u00e3o, em nanogramas por mililitro (ng\/ml);<\/div>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\"><span class=\"container-rkuXQi math-inline\" data-custom-copy-text=\"\\(V_1\\)\">V1<\/span>\u00a0\u2014 \u2014 Volume da solu\u00e7\u00e3o amostral para determina\u00e7\u00e3o, em mililitros (ml);<\/div>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\"><span class=\"container-rkuXQi math-inline single-Z69glH\" data-custom-copy-text=\"V\">V<\/span>\u00a0\u2014 \u2014 Volume da amostra original de \u00e1gua, em mililitros (ml);<\/div>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">1000 \u2013 \u2013 Fator de convers\u00e3o.<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>1. Method Overview After appropriate treatment, the sample is atomized in a graphite furnace, and the absorbance is measured at 283.3 nm. Within a certain concentration range, the absorbance of lead is proportional to its content, and quantification is performed by comparison with a standard series. 2. Instruments and Reagents 2.1 Instruments and Equipment 2.1.1 [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[36,73],"tags":[],"class_list":["post-3790","post","type-post","status-publish","format-standard","hentry","category-applications","category-food-and-drugs"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.pgeneral.com\/pt\/wp-json\/wp\/v2\/posts\/3790","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pgeneral.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pgeneral.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pgeneral.com\/pt\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pgeneral.com\/pt\/wp-json\/wp\/v2\/comments?post=3790"}],"version-history":[{"count":0,"href":"https:\/\/www.pgeneral.com\/pt\/wp-json\/wp\/v2\/posts\/3790\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.pgeneral.com\/pt\/wp-json\/wp\/v2\/media?parent=3790"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pgeneral.com\/pt\/wp-json\/wp\/v2\/categories?post=3790"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pgeneral.com\/pt\/wp-json\/wp\/v2\/tags?post=3790"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}