{"id":5199,"date":"2026-09-10T16:17:42","date_gmt":"2026-09-10T08:17:42","guid":{"rendered":"https:\/\/www.pgeneral.com\/?p=5199"},"modified":"2026-09-10T16:17:42","modified_gmt":"2026-09-10T08:17:42","slug":"determination-of-sodium-oxide-in-alumina-powder-flame-atomic-absorption-spectrometry","status":"publish","type":"post","link":"https:\/\/www.pgeneral.com\/ja\/applications\/determination-of-sodium-oxide-in-alumina-powder-flame-atomic-absorption-spectrometry","title":{"rendered":"\u30a2\u30eb\u30df\u30ca\u7c89\u672b\u4e2d\u306e\u9178\u5316\u30ca\u30c8\u30ea\u30a6\u30e0\u306e\u5b9a\u91cf\uff08\u30d5\u30ec\u30fc\u30e0\u539f\u5b50\u5438\u5149\u5206\u5149\u6cd5\uff09"},"content":{"rendered":"<h2>1 \u65b9\u6cd5\u6982\u8981<\/h2>\n<p>\u8a66\u6599\u3092\u52a0\u71b1\u3057\u3001\u786b\u9178\u3068\u30ea\u30f3\u9178\u306e\u6df7\u5408\u6db2\u3092\u5165\u308c\u305f\u77f3\u82f1\u30d3\u30fc\u30ab\u30fc\u306b\u6eb6\u89e3\u3055\u305b\u308b\u3002\u539f\u5b50\u5438\u5149\u5149\u5ea6\u8a08\u3092\u7528\u3044\u3001\u7a7a\u6c17\u30a2\u30bb\u30c1\u30ec\u30f3\u708e\u3067589.0 nm\u306b\u304a\u3051\u308b\u9178\u5316\u30ca\u30c8\u30ea\u30a6\u30e0\u306e\u5438\u5149\u5ea6\u3092\u6e2c\u5b9a\u3059\u308b\u3002\u4e00\u5b9a\u306e\u6fc3\u5ea6\u7bc4\u56f2\u5185\u3067\u306f\u3001\u30ca\u30c8\u30ea\u30a6\u30e0\u306e\u5438\u5149\u5ea6\u306f\u305d\u306e\u542b\u6709\u91cf\u306b\u6bd4\u4f8b\u3059\u308b\u305f\u3081\u3001\u6a19\u6e96\u8a66\u6599\u3068\u306e\u6bd4\u8f03\u306b\u3088\u3063\u3066\u5b9a\u91cf\u3092\u884c\u3046\u3002<\/p>\n<h2>2 \u9069\u7528\u7bc4\u56f2<\/h2>\n<p>\u3053\u306e\u65b9\u6cd5\u306f\u3001\u30a2\u30eb\u30df\u30ca\u7c89\u672b\u4e2d\u306e\u9178\u5316\u30ca\u30c8\u30ea\u30a6\u30e0\u542b\u6709\u91cf\u306e\u6e2c\u5b9a\u306b\u9069\u7528\u53ef\u80fd\u3067\u3042\u308b\u3002<\/p>\n<h2>3 \u53c2\u7167\u57fa\u6e96<\/h2>\n<p>GB\/T 6609.5-2004\u3001\u30a2\u30eb\u30df\u30ca\u306e\u5316\u5b66\u5206\u6790\u53ca\u3073\u7269\u6027\u8a66\u9a13\u65b9\u6cd5 \u2015 \u9178\u5316\u30ca\u30c8\u30ea\u30a6\u30e0\u542b\u6709\u91cf\u306e\u6e2c\u5b9a\u3001\u65b9\u6cd52<\/p>\n<h2>4\uff0e\u5668\u5177\u304a\u3088\u3073\u8a66\u85ac<\/h2>\n<h3><strong><b>4.1\u8a08\u5668\u8a2d\u5099<\/b><\/strong><\/h3>\n<h4><strong><b>4.1.1 \u8a66\u9a13\u6a5f\u5668<\/b><\/strong><\/h4>\n<table>\n<tbody>\n<tr>\n<td><strong><b>\u3044\u3084<\/b><\/strong><\/td>\n<td><strong><b>\u540d\u524d<\/b><\/strong><\/td>\n<td><strong><b>\u91cf<\/b><\/strong><\/td>\n<td><strong><b>\u6280\u8853\u8981\u4ef6<\/b><\/strong><\/td>\n<td><strong><b>\u30a2\u30af\u30bb\u30b5\u30ea\u30fc<\/b><\/strong><\/td>\n<\/tr>\n<tr>\n<td>1<\/td>\n<td>\u539f\u5b50\u5438\u5149\u5149\u5ea6\u8a08\uff08TAS 990\uff09<\/td>\n<td>1\u30bb\u30c3\u30c8<\/td>\n<td>\u2014<\/td>\n<td>\u30ca\u30c8\u30ea\u30a6\u30e0\u4e2d\u7a7a\u9670\u6975\u30e9\u30f3\u30d7<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>\u7a7a\u6c17\u5727\u7e2e\u6a5f<\/td>\n<td>1\u30bb\u30c3\u30c8<\/td>\n<td>\u8a55\u4fa1\u3055\u308c\u305f\u6392\u6c17\u5727: 0.3 MPa<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>\u30a2\u30bb\u30c1\u30ec\u30f3<\/td>\n<td>1\u3064\u306e\u30b7\u30ea\u30f3\u30c0\u30fc<\/td>\n<td>\u7d14\u5ea6 \u226599.99%<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>1 Method Overview The sample is heated and dissolved in a quartz beaker with mixed sulfuric\u001ephosphoric acid. Using an air\u001eacetylene flame, the absorbance of sodium oxide is measured at 589.0 nm on an atomic absorption spectrophotometer. Within a certain concentration range, the absorbance of sodium is proportional to its content, and quantification is carried out by comparison with the standard series. 2 Scope of Application This method is applicable to the determination of sodium oxide content in alumina powder. 3 Reference Basis GB\/T 6609.5-2004, Methods for chemical analysis and physical property testing of alumina \u2014 Determination of sodium oxide content, Method 2 4 Instruments and Reagents 4.1 Instruments and Equipment [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":4824,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[81,36],"tags":[],"class_list":["post-5199","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-petrochemical-and-chemical","category-applications"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.pgeneral.com\/ja\/wp-json\/wp\/v2\/posts\/5199","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pgeneral.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pgeneral.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pgeneral.com\/ja\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pgeneral.com\/ja\/wp-json\/wp\/v2\/comments?post=5199"}],"version-history":[{"count":1,"href":"https:\/\/www.pgeneral.com\/ja\/wp-json\/wp\/v2\/posts\/5199\/revisions"}],"predecessor-version":[{"id":5200,"href":"https:\/\/www.pgeneral.com\/ja\/wp-json\/wp\/v2\/posts\/5199\/revisions\/5200"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.pgeneral.com\/ja\/wp-json\/wp\/v2\/media\/4824"}],"wp:attachment":[{"href":"https:\/\/www.pgeneral.com\/ja\/wp-json\/wp\/v2\/media?parent=5199"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pgeneral.com\/ja\/wp-json\/wp\/v2\/categories?post=5199"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pgeneral.com\/ja\/wp-json\/wp\/v2\/tags?post=5199"}],"curies":[{"name":"WP","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}