{"id":3783,"date":"2025-07-28T14:23:55","date_gmt":"2025-07-28T06:23:55","guid":{"rendered":"https:\/\/www.pgeneral.com\/?p=3783"},"modified":"2025-07-28T14:23:55","modified_gmt":"2025-07-28T06:23:55","slug":"determination-of-lead-in-aluminum-alloys-flame-atomic-absorption-spectrometry","status":"publish","type":"post","link":"https:\/\/www.pgeneral.com\/id\/applications\/determination-of-lead-in-aluminum-alloys-flame-atomic-absorption-spectrometry","title":{"rendered":"Penentuan Timbal dalam Paduan Aluminium &#8211; Spektrometri Penyerapan Atom Api"},"content":{"rendered":"<h2 class=\"header-vfC6AV auto-hide-last-sibling-br\">1. Gambaran Umum Metode<\/h2>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Cerna basah: Larutkan sampel dengan asam klorida, asam nitrat, dan hidrogen peroksida. Tentukan timbal pada panjang gelombang 283,3 nm menggunakan api netral udara-asetilena.<\/div>\n<div>\n<h2 class=\"header-vfC6AV auto-hide-last-sibling-br\">2. Instrumen dan Reagen<\/h2>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.1 Instrumen dan Peralatan<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.1.1 Instrumen Pengujian<\/h4>\n<div class=\"auto-hide-last-sibling-br table-container-GhL7Lo\">\n<table>\n<thead>\n<tr>\n<th>Serial No.<\/th>\n<th>Nama<\/th>\n<th>Kuantitas<\/th>\n<th>Persyaratan Teknis<\/th>\n<th>Aksesoris<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Spektrofotometer penyerapan atom api<\/td>\n<td>1 set<\/td>\n<td><\/td>\n<td>Lampu katoda berongga timbal<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Acetilena<\/td>\n<td>1 silinder<\/td>\n<td>Kemurnian \u2265 99,99%<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Kompresor udara<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.1.2 Peralatan Praperawatan<\/h4>\n<div class=\"auto-hide-last-sibling-br table-container-GhL7Lo\">\n<table>\n<thead>\n<tr>\n<th>Serial No.<\/th>\n<th>Nama<\/th>\n<th>Kuantitas<\/th>\n<th>Persyaratan Teknis<\/th>\n<th>Aksesoris<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Piring panas listrik yang dikendalikan suhu<\/td>\n<td>1 set<\/td>\n<td>Suhu nominal: suhu kamar ~ 300 \u2103<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Keseimbangan elektronik<\/td>\n<td>1 set<\/td>\n<td>Sensitivitas: 0,1 mg<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Sistem air ultramurni<\/td>\n<td>1 set<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>Mikropipet<\/td>\n<td>1 masing-masing<\/td>\n<td>20 \u03bcL ~ 200 \u03bcL; 100 \u03bcL ~ 1000 \u03bcL<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>Kolos volumetrik<\/td>\n<td>Beberapa<\/td>\n<td>100 ml<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>Tabung uji<\/td>\n<td>Beberapa<\/td>\n<td>25 ml<\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.2 Reagen<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.2.1 Reagen<\/h4>\n<div class=\"auto-hide-last-sibling-br table-container-GhL7Lo\">\n<table>\n<thead>\n<tr>\n<th>Serial No.<\/th>\n<th>Nama<\/th>\n<th>Persyaratan Teknis<\/th>\n<th>Perkataan<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Asam klorida<\/td>\n<td>Reagen yang dijamin<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Asam nitrat<\/td>\n<td>kelas MOS<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 class=\"header-vfC6AV auto-hide-last-sibling-br\">3. Prosedur Operasional<\/h2>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.1 Pengolahan Sampel<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.1.1 Persiapan Solusi Uji<\/h4>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Metode eksperimental: Timbangkan 0,25 g sampel ke dalam gelas, tambahkan 15 mL asam campuran (HCl: HNO) \u2083: H\u2082 O = 6:1:7), panas sampai benar-benar larut, dan dingin. Transfer ke botol volumetrik 100 mL, cairkan ke tanda, dan campur dengan baik. Nol dengan larutan kosong, dan menentukan pada panjang gelombang 283,3 nm menggunakan api udara-asetilena.<\/div>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.1.2 Persiapan Solusi Standar<\/h4>\n<ol class=\"auto-hide-last-sibling-br\">\n<li>Persiapan seri standar timah: Pipet secara akurat 0,0, 0,1, 0,2, 0,4, dan 0,8 mL larutan stok standar timah (1000,0 \u03bcg \/ mL) masing-masing ke dalam botol volumetrik 100 mL, cairkan ke tanda dengan (1 99) asam klorhidrat, dan campur dengan baik. Konsentrasi seri larutan ini adalah 0,0, 1,0, 2,0, 4,0, dan 8,0 \u03bcg \/ mL.<\/li>\n<\/ol>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.2 Pengujian Sampel<\/h3>\n<ol class=\"auto-hide-last-sibling-br\">\n<li>Kondisi Pengujian Kondisi referensi untuk deteksi spektrofotometer penyerapan atom api<\/li>\n<\/ol>\n<div class=\"auto-hide-last-sibling-br table-container-GhL7Lo\">\n<table style=\"height: 190px;\" width=\"511\">\n<thead>\n<tr>\n<th>Elemen<\/th>\n<th>Memimpin<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Panjang gelombang (nm)<\/td>\n<td>283.3<\/td>\n<\/tr>\n<tr>\n<td>Lebar pita spektral (nm)<\/td>\n<td>0.4<\/td>\n<\/tr>\n<tr>\n<td>Arus lampu elemen (mA)<\/td>\n<td>6.0<\/td>\n<\/tr>\n<tr>\n<td>Tinggi bahan bakar (mm)<\/td>\n<td>6<\/td>\n<\/tr>\n<tr>\n<td>Tingkat aliran bahan bakar (mL \/ min)<\/td>\n<td>1500<\/td>\n<\/tr>\n<tr>\n<td>Tekanan kompresor udara (MPa)<\/td>\n<td>0.22<\/td>\n<\/tr>\n<tr>\n<td>Metode koreksi latar belakang<\/td>\n<td>Tidak ada<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<ol class=\"auto-hide-last-sibling-br\" start=\"2\">\n<li>Pengujian Sampel Sesuaikan instrumen dengan keadaan kerja yang optimal, menyalakan api, menyesuaikan laju aliran bahan bakar, menguji solusi standar dan solusi sampel secara berurutan, membaca data, memasukkan berat sampel, dan memeriksa dan merekam hasilnya.<\/li>\n<\/ol>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.3 Perhitungan Hasil<\/h3>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\"><img decoding=\"async\" class=\"alignnone wp-image-3784\" src=\"http:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/07\/\u4f01\u4e1a\u5fae\u4fe1\u622a\u56fe_17536837467552-300x134.png\" alt=\"\" width=\"231\" height=\"103\" srcset=\"https:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/07\/\u4f01\u4e1a\u5fae\u4fe1\u622a\u56fe_17536837467552-300x134.png 300w, https:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/07\/\u4f01\u4e1a\u5fae\u4fe1\u622a\u56fe_17536837467552-18x8.png 18w, https:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/07\/\u4f01\u4e1a\u5fae\u4fe1\u622a\u56fe_17536837467552.png 390w\" sizes=\"(max-width: 231px) 100vw, 231px\" \/><\/div>\n<div>\n<div class=\"auto-hide-last-sibling-br table-container-GhL7Lo\">\n<div class=\"auto-hide-last-sibling-br table-container-GhL7Lo\">\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Di mana:<\/div>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">X &#8212; Kandungan timah dalam sampel, dalam miligram per kilogram (mg \/ kg);<\/div>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">\u03c1 &#8212; Konsentrasi massa timah dalam larutan sampel yang akan diuji, dalam mikrogram per mililiter (\u03bcg \/ mL);<\/div>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">\u03c1\u2080 &#8212; Konsentrasi massa timah dalam larutan kosong, dalam mikrogram per mililiter (\u03bcg \/ mL);<\/div>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">f &#8212; Faktor pengenceran larutan pencernaan sampel;<\/div>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Di &#8212; Total volume larutan pencernaan sampel, dalam mililiter (mL);<\/div>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">m &#8212; Massa sampel, dalam gram (g).<\/div>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>1. Method Overview Wet digestion: Dissolve the sample with hydrochloric acid, nitric acid, and hydrogen peroxide. Determine lead at a wavelength of 283.3 nm using an air-acetylene neutral flame. 2. Instruments and Reagents 2.1 Instruments and Equipment 2.1.1 Testing Instruments Serial No. Name Quantity Technical Requirements Accessories 1 Flame atomic absorption spectrophotometer 1 set Lead [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[81,36],"tags":[],"class_list":["post-3783","post","type-post","status-publish","format-standard","hentry","category-petrochemical-and-chemical","category-applications"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.pgeneral.com\/id\/wp-json\/wp\/v2\/posts\/3783","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pgeneral.com\/id\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pgeneral.com\/id\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pgeneral.com\/id\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pgeneral.com\/id\/wp-json\/wp\/v2\/comments?post=3783"}],"version-history":[{"count":0,"href":"https:\/\/www.pgeneral.com\/id\/wp-json\/wp\/v2\/posts\/3783\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.pgeneral.com\/id\/wp-json\/wp\/v2\/media?parent=3783"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pgeneral.com\/id\/wp-json\/wp\/v2\/categories?post=3783"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pgeneral.com\/id\/wp-json\/wp\/v2\/tags?post=3783"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}