{"id":3914,"date":"2025-09-09T11:17:07","date_gmt":"2025-09-09T03:17:07","guid":{"rendered":"https:\/\/www.pgeneral.com\/?p=3914"},"modified":"2025-09-09T11:17:07","modified_gmt":"2025-09-09T03:17:07","slug":"determination-of-nickel-in-reflective-coating-of-mirrors-flame-atomic-absorption-spectrometry","status":"publish","type":"post","link":"https:\/\/www.pgeneral.com\/fr\/applications\/determination-of-nickel-in-reflective-coating-of-mirrors-flame-atomic-absorption-spectrometry","title":{"rendered":"D\u00e9termination du nickel dans le rev\u00eatement r\u00e9fl\u00e9chissant des miroirs (spectrom\u00e9trie d'absorption atomique de flamme)"},"content":{"rendered":"<h2 class=\"header-vfC6AV auto-hide-last-sibling-br\">1. Aper\u00e7u de la m\u00e9thode<\/h2>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Apr\u00e8s le pr\u00e9traitement de l'\u00e9chantillon, il est introduit dans un spectrom\u00e8tre d'absorption atomique et atomis\u00e9 par la flamme pour d\u00e9terminer l'absorbance. Dans une certaine gamme de concentration, la valeur d'absorbance est proportionnelle \u00e0 la teneur, et la quantification est effectu\u00e9e par comparaison avec la s\u00e9rie standard.<\/div>\n<div>\n<h2 class=\"header-vfC6AV auto-hide-last-sibling-br\">2. Instruments et r\u00e9actifs<\/h2>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.1 Instruments et \u00e9quipements<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.1.1 Instruments d'essai<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-GhL7Lo\" data-scroll-inline-overflow=\"true\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"false\" data-scroll-inline-end-overflow=\"true\">\n<div class=\"table-scroll-container-hgHkfW mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>N\u00b0 de s\u00e9rie.<\/th>\n<th>Nom<\/th>\n<th>Quantit\u00e9<\/th>\n<th>Exigences techniques<\/th>\n<th>Accessoires<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Spectrophotom\u00e8tre d'absorption atomique de flamme<\/td>\n<td>1 ensemble<\/td>\n<td>&amp; quot; 8211;<\/td>\n<td>Lampe \u00e0 cathode creuse au nickel<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Compresseur d'air<\/td>\n<td>1 ensemble<\/td>\n<td>Pression nominale de d\u00e9charge: 0,3 MPa<\/td>\n<td>&amp; quot; 8211;<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>gaz ac\u00e9tyl\u00e8ne<\/td>\n<td>1 cylindre<\/td>\n<td>Puret\u00e9 \u2265 99,99%<\/td>\n<td>&amp; quot; 8211;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.1.2 \u00c9quipement de pr\u00e9traitement des \u00e9chantillons<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-GhL7Lo\" data-scroll-inline-overflow=\"true\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"false\" data-scroll-inline-end-overflow=\"true\">\n<div class=\"table-scroll-container-hgHkfW mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>N\u00b0 de s\u00e9rie.<\/th>\n<th>Nom<\/th>\n<th>Quantit\u00e9<\/th>\n<th>Exigences techniques<\/th>\n<th>Accessoires<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>\u00c9quilibre \u00e9lectronique<\/td>\n<td>1 ensemble<\/td>\n<td>Sensibilit\u00e9 : 0,1 mg<\/td>\n<td>&amp; quot; 8211;<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Verres en polyt\u00e9trafluoro\u00e9thyl\u00e8ne (PTFE)<\/td>\n<td>Plusieurs<\/td>\n<td>Volume: 100 mL<\/td>\n<td>Incluant les couvercles de verre PTFE<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Plaque chaude r\u00e9glable<\/td>\n<td>1 ensemble<\/td>\n<td>Plage de temp\u00e9rature: Temp\u00e9rature ambiante ~ 300 \u2103<\/td>\n<td>&amp; quot; 8211;<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>Micropipettes<\/td>\n<td>1 chacun<\/td>\n<td>Port\u00e9es de volume: 20 \u03bcL ~ 200 \u03bcL; 1000 \u03bcL \u00e0 5000 \u03bcL<\/td>\n<td>&amp; quot; 8211;<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>Flacons volumetriques<\/td>\n<td>Plusieurs<\/td>\n<td>Volumes: 100 mL, 1000 mL<\/td>\n<td>&amp; quot; 8211;<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>Tubes colorim\u00e9triques<\/td>\n<td>Plusieurs<\/td>\n<td>Volume: 25 mL<\/td>\n<td>&amp; quot; 8211;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.2 R\u00e9actifs<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.2.1 R\u00e9actifs bruts<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-GhL7Lo\" data-scroll-inline-overflow=\"false\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"true\" data-scroll-inline-end-overflow=\"false\">\n<div class=\"table-scroll-container-hgHkfW mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>N\u00b0 de s\u00e9rie.<\/th>\n<th>Nom<\/th>\n<th>Exigences techniques<\/th>\n<th>Remarques<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Acide nitrique<\/td>\n<td>Classe MOS<\/td>\n<td>&amp; quot; 8211;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.2.2 R\u00e9actifs pr\u00e9par\u00e9s<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-GhL7Lo\" data-scroll-inline-overflow=\"true\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"false\" data-scroll-inline-end-overflow=\"true\">\n<div class=\"table-scroll-container-hgHkfW mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>N\u00b0 de s\u00e9rie.<\/th>\n<th>Nom<\/th>\n<th>M\u00e9thode de pr\u00e9paration<\/th>\n<th>Remarques<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Solution d'acide nitrique (1 99)<\/td>\n<td>Mesurer 10 mL d'acide nitrique, ajouter \u00e0 990 mL d'eau et bien m\u00e9langer.<\/td>\n<td>&amp; quot; 8211;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.3 Normes de r\u00e9f\u00e9rence<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.3.1 Solution de stock<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-GhL7Lo\" data-scroll-inline-overflow=\"true\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"false\" data-scroll-inline-end-overflow=\"true\">\n<div class=\"table-scroll-container-hgHkfW mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>N\u00b0 de s\u00e9rie.<\/th>\n<th>- Non, non.<\/th>\n<th>Nom<\/th>\n<th>Exigences techniques<\/th>\n<th>Remarques<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>GBW08618<\/td>\n<td>Solution standard \u00e0 \u00e9l\u00e9ment unique au nickel<\/td>\n<td>Concentration: 1000 \u03bcg\/mL<\/td>\n<td>Institut national de m\u00e9trologie, Chine<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h2 class=\"header-vfC6AV auto-hide-last-sibling-br\">3. Proc\u00e9dure de fonctionnement<\/h2>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.1 Pr\u00e9paration de l'\u00e9chantillon<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.1.1 Pr\u00e9paration de la solution d'essai<\/h4>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Pr\u00e9traitement de l'\u00e9chantillon:<br class=\"container-utlnW2 wrapper-d0Cc1k undefined\" \/>Placez tout le miroir dans un verre en PTFE avec le c\u00f4t\u00e9 r\u00e9fl\u00e9chissant tourn\u00e9 vers le haut. Ajouter 1 mL d\u2019eau et 5 mL d\u2019acide nitrique (le niveau liquide doit couvrir compl\u00e8tement la surface r\u00e9fl\u00e9chissante du miroir). Couvrez le verre, chauffer pour la digestion pendant 1 heure jusqu'\u00e0 ce que le rev\u00eatement r\u00e9fl\u00e9chissant du miroir disparaisse compl\u00e8tement. Retirez le verre, refroidissez-le, diluez la solution au volume marqu\u00e9 dans un tube colorim\u00e9trique de 25 ml, agitez bien et transf\u00e9rez-le dans une bouteille en plastique pour le stockage. Pr\u00e9parer un \u00e9chantillon vide simultan\u00e9ment.<\/div>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.1.2 Pr\u00e9paration de solutions standard<\/h4>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Pr\u00e9paration de la s\u00e9rie standard du nickel:<br class=\"container-utlnW2 wrapper-d0Cc1k undefined\" \/>Pipeter respectivement 0 mL, 25 \u03bcL, 50 \u03bcL, 100 \u03bcL et 150 \u03bcL de solution standard de nickel (1000 \u03bcg\/mL) dans des flacons volumetriques de 100 mL. Diluer au volume marqu\u00e9 avec une solution d'acide nitrique (1 99) et bien m\u00e9langer. Les concentrations de cette s\u00e9rie standard sont: 0 \u03bcg\/mL, 0,25 \u03bcg\/mL, 0,50 \u03bcg\/mL, 1,00 \u03bcg\/mL et 1,50 \u03bcg\/mL.<\/div>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.2 Essais d'\u00e9chantillons<\/h3>\n<ol class=\"auto-hide-last-sibling-br\">\n<li>Conditions d'essai<br class=\"container-utlnW2 wrapper-d0Cc1k undefined\" \/>Conditions de r\u00e9f\u00e9rence pour la d\u00e9tection par spectrophotom\u00e8tre d'absorption atomique de la flamme<\/li>\n<\/ol>\n<p><br class=\"container-utlnW2 wrapper-d0Cc1k undefined\" \/><\/p>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-GhL7Lo\" data-scroll-inline-overflow=\"false\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"true\" data-scroll-inline-end-overflow=\"false\">\n<div class=\"table-scroll-container-hgHkfW mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Param\u00e8tre<\/th>\n<th>Sp\u00e9cification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Longueur d'onde<\/td>\n<td>232,0 nm<\/td>\n<\/tr>\n<tr>\n<td>Bande passante spectrale<\/td>\n<td>0,1 nm<\/td>\n<\/tr>\n<tr>\n<td>\u00c9l\u00e9ment lampe courant<\/td>\n<td>4,0 mA<\/td>\n<\/tr>\n<tr>\n<td>Hauteur du br\u00fbleur<\/td>\n<td>6 mm<\/td>\n<\/tr>\n<tr>\n<td>D\u00e9bit de gaz combustible<\/td>\n<td>1300 mL\/min<\/td>\n<\/tr>\n<tr>\n<td>Pression du compresseur d'air<\/td>\n<td>0,22 MPa<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p><br class=\"container-utlnW2 wrapper-d0Cc1k undefined\" \/><\/p>\n<ol class=\"auto-hide-last-sibling-br\" start=\"2\">\n<li>Tests d'\u00e9chantillons<br class=\"container-utlnW2 wrapper-d0Cc1k undefined\" \/>Ajustez l'instrument \u00e0 l'\u00e9tat de travail optimal et z\u00e9ro avec de l'eau. D\u00e9terminer l'absorbance des solutions standard, de la solution d'essai blanche et de la solution d'essai en s\u00e9quence.<\/li>\n<\/ol>\n<p><br class=\"container-utlnW2 wrapper-d0Cc1k undefined\" \/><\/p>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Soustraire l'absorbance de la solution standard z\u00e9ro de l'absorbance de chaque solution standard. Tracer une courbe de travail avec la concentration en masse (\u03bcg\/mL) comme abscisse et l'absorbance correspondante comme ordonn\u00e9e. En fonction de l'absorbance mesur\u00e9e de la solution d'essai, d\u00e9terminer la concentration en masse de nickel de la courbe de travail.<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>1. Method Overview After the sample is pretreated, it is introduced into an atomic absorption spectrometer and atomized by flame to determine the absorbance. Within a certain concentration range, the absorbance value is proportional to the content, and quantification is performed by comparison with the standard series. 2. Instruments and Reagents 2.1 Instruments and Equipment [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[81,36],"tags":[],"class_list":["post-3914","post","type-post","status-publish","format-standard","hentry","category-petrochemical-and-chemical","category-applications"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.pgeneral.com\/fr\/wp-json\/wp\/v2\/posts\/3914","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pgeneral.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pgeneral.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pgeneral.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pgeneral.com\/fr\/wp-json\/wp\/v2\/comments?post=3914"}],"version-history":[{"count":0,"href":"https:\/\/www.pgeneral.com\/fr\/wp-json\/wp\/v2\/posts\/3914\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.pgeneral.com\/fr\/wp-json\/wp\/v2\/media?parent=3914"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pgeneral.com\/fr\/wp-json\/wp\/v2\/categories?post=3914"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pgeneral.com\/fr\/wp-json\/wp\/v2\/tags?post=3914"}],"curies":[{"name":"WP","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}