{"id":3790,"date":"2025-07-28T16:03:51","date_gmt":"2025-07-28T08:03:51","guid":{"rendered":"https:\/\/www.pgeneral.com\/?p=3790"},"modified":"2025-07-28T16:03:51","modified_gmt":"2025-07-28T08:03:51","slug":"determination-of-lead-in-drinking-water-graphite-furnace-atomic-absorption-spectrometry","status":"publish","type":"post","link":"https:\/\/www.pgeneral.com\/fr\/applications\/determination-of-lead-in-drinking-water-graphite-furnace-atomic-absorption-spectrometry","title":{"rendered":"D\u00e9termination du plomb dans l'eau potable (spectrom\u00e9trie d'absorption atomique au four \u00e0 graphite)"},"content":{"rendered":"<h2 class=\"header-vfC6AV auto-hide-last-sibling-br\">1. Aper\u00e7u de la m\u00e9thode<\/h2>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Apr\u00e8s un traitement appropri\u00e9, l'\u00e9chantillon est atomis\u00e9 dans un four \u00e0 graphite et l'absorbance est mesur\u00e9e \u00e0 283,3 nm. Dans une certaine gamme de concentration, l'absorbance du plomb est proportionnelle \u00e0 sa teneur, et la quantification est effectu\u00e9e par comparaison avec une s\u00e9rie standard.<\/div>\n<div>\n<h2 class=\"header-vfC6AV auto-hide-last-sibling-br\">2. Instruments et r\u00e9actifs<\/h2>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.1 Instruments et \u00e9quipements<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.1.1 Instruments d'essai<\/h4>\n<div class=\"auto-hide-last-sibling-br table-container-GhL7Lo\">\n<table>\n<thead>\n<tr>\n<th>Nom<\/th>\n<th>Quantit\u00e9<\/th>\n<th>Exigences techniques<\/th>\n<th>Accessoires<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Micropipette<\/td>\n<td>1 chacun<\/td>\n<td>100 \u03bcL ~ 1000 \u03bcL, 1000 \u03bcL ~ 5000 \u03bcL, 5 ~ 50 \u03bcL<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Flacon volum\u00e9trique<\/td>\n<td>Plusieurs<\/td>\n<td>100 mL<\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.1.2 \u00c9quipement de pr\u00e9traitement<\/h4>\n<div class=\"auto-hide-last-sibling-br table-container-GhL7Lo\">\n<table>\n<thead>\n<tr>\n<th>N\u00b0 de s\u00e9rie.<\/th>\n<th>Nom<\/th>\n<th>Quantit\u00e9<\/th>\n<th>Exigences techniques<\/th>\n<th>Accessoires<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Micropipette<\/td>\n<td>1 chacun<\/td>\n<td>100 \u03bcL ~ 1000 \u03bcL, 1000 \u03bcL ~ 5000 \u03bcL, 5 ~ 50 \u03bcL<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Flacon volum\u00e9trique<\/td>\n<td>Plusieurs<\/td>\n<td>100 mL<\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.2 R\u00e9actifs<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.2.1 R\u00e9actifs<\/h4>\n<div class=\"auto-hide-last-sibling-br table-container-GhL7Lo\">\n<table>\n<thead>\n<tr>\n<th>N\u00b0 de s\u00e9rie.<\/th>\n<th>Nom<\/th>\n<th>Exigences techniques<\/th>\n<th>Remarques<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Acide nitrique<\/td>\n<td>qualit\u00e9 MOS<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.3 Normes de r\u00e9f\u00e9rence<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.3.1 Solutions en stock<\/h4>\n<div class=\"auto-hide-last-sibling-br table-container-GhL7Lo\">\n<table>\n<thead>\n<tr>\n<th>N\u00b0 de s\u00e9rie.<\/th>\n<th>- Non, non.<\/th>\n<th>Nom<\/th>\n<th>Exigences techniques<\/th>\n<th>Remarques<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>GBW 08619<\/td>\n<td>Substance standard en solution \u00e0 un seul \u00e9l\u00e9ment de plomb<\/td>\n<td>1000 \u03bcg\/mL<\/td>\n<td>Institut national de m\u00e9trologie, Chine<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2 class=\"header-vfC6AV auto-hide-last-sibling-br\">3. Proc\u00e9dures op\u00e9rationnelles<\/h2>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.1 Traitement des \u00e9chantillons<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.1.1 Pr\u00e9paration de la solution d'essai<\/h4>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Prenez 100 mL d'\u00e9chantillon d'eau dans un flacon volum\u00e9trique, ajoutez 0,5 mL d'acide nitrique et m\u00e9langez bien. Effectuez un test vide \u00e0 c\u00f4t\u00e9 de l'\u00e9chantillon.<\/div>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.1.2 Pr\u00e9paration de solutions standard<\/h4>\n<ol class=\"auto-hide-last-sibling-br\">\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Pr\u00e9paration de la solution interm\u00e9diaire standard de plomb: solution standard de plomb (1,0 \u03bcg\/mL): pipetter avec pr\u00e9cision 0,1 mL de solution standard de plomb (1000 \u03bcg\/mL) dans un ballon volumetrique de 100 mL, ajouter 0,5 mL de solution d'acide nitrique, diluer jusqu'\u00e0 la marque et bien agiter.<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Pr\u00e9paration de la s\u00e9rie standard de plomb: Pipettez avec pr\u00e9cision 0,0, 0,1, 0,2, 0,3 et 0,4 mL de solution standard de plomb (1,0 \u03bcg\/mL) dans des flacons volumetriques de 10 mL respectivement. Ajouter 0,5 mL de solution d'acide nitrique \u00e0 chacune, diluer jusqu'\u00e0 la marque et obtenir des solutions de s\u00e9rie standard de plomb \u00e0 des concentrations de 0,0, 10,0, 20,0, 30,0 et 40,0 ng\/mL.<\/div>\n<\/li>\n<\/ol>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.2 Essais d'\u00e9chantillons<\/h3>\n<ol class=\"auto-hide-last-sibling-br\">\n<li>Conditions d'essai Conditions de r\u00e9f\u00e9rence pour la d\u00e9tection par spectrophotom\u00e8tre d'absorption atomique au four \u00e0 graphite<\/li>\n<\/ol>\n<div class=\"auto-hide-last-sibling-br table-container-GhL7Lo\">\n<table>\n<thead>\n<tr>\n<th>\u00c9l\u00e9ment<\/th>\n<th>Plomb<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Longueur d'onde (nm)<\/td>\n<td>283.3<\/td>\n<\/tr>\n<tr>\n<td>Bande passante spectrale (nm)<\/td>\n<td>0.4<\/td>\n<\/tr>\n<tr>\n<td>Courant de la lampe de l'\u00e9l\u00e9ment (mA)<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>M\u00e9thode de correction de fond<\/td>\n<td>Lampe \u00e0 deut\u00e9rium<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<\/div>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\"><strong>Programme de chauffage de four \u00e0 graphite<\/strong><\/div>\n<p>&nbsp;<\/p>\n<div class=\"auto-hide-last-sibling-br table-container-GhL7Lo\">\n<table>\n<thead>\n<tr>\n<th>\u00c9tape<\/th>\n<th>Proc\u00e9dure<\/th>\n<th>Temp\u00e9rature (\u2103)<\/th>\n<th>Temps de rampe (s)<\/th>\n<th>Temps d'attente (s)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>S\u00e9chage<\/td>\n<td>120<\/td>\n<td>10<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Ashing<\/td>\n<td>450<\/td>\n<td>10<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Atomization<\/td>\n<td>1800<\/td>\n<td>0<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>Nettoyage<\/td>\n<td>1900<\/td>\n<td>1<\/td>\n<td>2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<ol class=\"auto-hide-last-sibling-br\" start=\"2\">\n<li>D\u00e9terminer l'absorbance des solutions standard, des solutions d'essai vierges et des solutions d'essai en s\u00e9quence. Soustraire l'absorbance de la solution standard z\u00e9ro de l'absorbance de chaque solution standard. Tracer une courbe de travail avec la concentration de masse comme abscisse et l'absorbance correspondante comme ordonn\u00e9e. En fonction de l'absorbance mesur\u00e9e de la solution d'essai, d\u00e9terminer la concentration en masse de plomb de la courbe de travail.<\/li>\n<\/ol>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.3 Calcul des r\u00e9sultats<\/h3>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Formule :<\/div>\n<p><img decoding=\"async\" class=\"alignnone  wp-image-3791\" src=\"http:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/07\/2222\u5fae\u4fe1\u56fe\u7247_20250728160213_3807-300x128.png\" alt=\"\" width=\"199\" height=\"85\" srcset=\"https:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/07\/2222\u5fae\u4fe1\u56fe\u7247_20250728160213_3807-300x129.png 300w, https:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/07\/2222\u5fae\u4fe1\u56fe\u7247_20250728160213_3807-18x8.png 18w, https:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/07\/2222\u5fae\u4fe1\u56fe\u7247_20250728160213_3807.png 303w\" sizes=\"(max-width: 199px) 100vw, 199px\" \/><\/p>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">O\u00f9:<\/div>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">\u03c1\u2014\u2014 Concentration en masse de plomb dans l\u2019\u00e9chantillon d\u2019eau, en milligrammes par litre (mg\/L);<\/div>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\"><span class=\"container-rkuXQi math-inline\" data-custom-copy-text=\"\\(\\rho_1\\)\">\u03c11<\/span>\u2014 Concentration en masse de plomb dans l'\u00e9chantillon d'eau obtenu \u00e0 partir de la courbe type, en nanogrammes par millilitre (ng\/mL);<\/div>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\"><span class=\"container-rkuXQi math-inline\" data-custom-copy-text=\"\\(V_1\\)\">V1<\/span>\u00a0\u2014 Volume de la solution d'\u00e9chantillon \u00e0 d\u00e9terminer, en millilitres (mL);<\/div>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\"><span class=\"container-rkuXQi math-inline single-Z69glH\" data-custom-copy-text=\"V\">V<\/span>\u00a0\u2014 Volume de l'\u00e9chantillon d'eau original, en millilitres (mL);<\/div>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">1000 \u2014 Facteur de conversion.<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>1. Method Overview After appropriate treatment, the sample is atomized in a graphite furnace, and the absorbance is measured at 283.3 nm. Within a certain concentration range, the absorbance of lead is proportional to its content, and quantification is performed by comparison with a standard series. 2. Instruments and Reagents 2.1 Instruments and Equipment 2.1.1 [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[36,73],"tags":[],"class_list":["post-3790","post","type-post","status-publish","format-standard","hentry","category-applications","category-food-and-drugs"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.pgeneral.com\/fr\/wp-json\/wp\/v2\/posts\/3790","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pgeneral.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pgeneral.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pgeneral.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pgeneral.com\/fr\/wp-json\/wp\/v2\/comments?post=3790"}],"version-history":[{"count":0,"href":"https:\/\/www.pgeneral.com\/fr\/wp-json\/wp\/v2\/posts\/3790\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.pgeneral.com\/fr\/wp-json\/wp\/v2\/media?parent=3790"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pgeneral.com\/fr\/wp-json\/wp\/v2\/categories?post=3790"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pgeneral.com\/fr\/wp-json\/wp\/v2\/tags?post=3790"}],"curies":[{"name":"WP","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}