{"id":3805,"date":"2025-08-01T11:09:02","date_gmt":"2025-08-01T03:09:02","guid":{"rendered":"https:\/\/www.pgeneral.com\/?p=3805"},"modified":"2025-08-01T11:20:01","modified_gmt":"2025-08-01T03:20:01","slug":"determination-of-copper-in-graphite-powder-flame-atomic-absorption-spectrometry","status":"publish","type":"post","link":"https:\/\/www.pgeneral.com\/de\/applications\/determination-of-copper-in-graphite-powder-flame-atomic-absorption-spectrometry","title":{"rendered":"Bestimmung von Kupfer in Graphitpulver &#8211; Flammenabsorptionsspektrometrie"},"content":{"rendered":"<h2 class=\"header-vfC6AV auto-hide-last-sibling-br\">1 Methodenblick<\/h2>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Nach dem Verdauen der Probe mit Aqua Regia erfolgt die Bestimmung mit dem Instrument unter Verwendung einer Luft-Acetylenflamme bei einer Wellenl\u00e4nge von 324,7 nm.<\/div>\n<div>\n<h2 class=\"header-vfC6AV auto-hide-last-sibling-br\">2 Instrumente und Reagentien<\/h2>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.1 Instrumente und Ausr\u00fcstung<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.1.1 Erkennungsinstrumente<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-GhL7Lo\" data-scroll-inline-overflow=\"true\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"false\" data-scroll-inline-end-overflow=\"true\">\n<div class=\"table-scroll-container-hgHkfW mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Seriennummer<\/th>\n<th>Name<\/th>\n<th>Menge<\/th>\n<th>Technische Anforderungen<\/th>\n<th>Zubeh\u00f6r<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Flammenabsorptionsspektrophotometer<\/td>\n<td>1 Satz<\/td>\n<td><\/td>\n<td>Kupferhohlkathodenlampe<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Acetylen<\/td>\n<td>1 Zylinder<\/td>\n<td>Reinheit \u2265 99,99%<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Luftkompressor<\/td>\n<td>1 Satz<\/td>\n<td>Nenndruck: 0,3 MPa<\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.1.2 Vorbehandlungsausr\u00fcstung<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-GhL7Lo\" data-scroll-inline-overflow=\"true\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"false\" data-scroll-inline-end-overflow=\"true\">\n<div class=\"table-scroll-container-hgHkfW mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Seriennummer<\/th>\n<th>Name<\/th>\n<th>Menge<\/th>\n<th>Technische Anforderungen<\/th>\n<th>Zubeh\u00f6r<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Temperaturgesteuerte Hei\u00dfplatte<\/td>\n<td>1 Satz<\/td>\n<td>Nenntemperatur: Raumtemperatur ~ 300 \u2103<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Elektronische Balance<\/td>\n<td>1 Satz<\/td>\n<td>Empfindlichkeit 0,1 mg<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Ultrareines Wasserger\u00e4t<\/td>\n<td>1 Satz<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>Mikropipette<\/td>\n<td>1 jedes<\/td>\n<td>20\u03bcL ~ 200\u03bcL; 100\u03bcL bis 1000\u03bcL<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>Volumetrische Flasche<\/td>\n<td>Mehrere<\/td>\n<td>100 ml<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>Testrohr<\/td>\n<td>Mehrere<\/td>\n<td>25 ml<\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.2 Reagenzien<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.2.1 Reagenzien<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-GhL7Lo\" data-scroll-inline-overflow=\"true\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"false\" data-scroll-inline-end-overflow=\"true\">\n<div class=\"table-scroll-container-hgHkfW mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Seriennummer<\/th>\n<th>Name<\/th>\n<th>Technische Anforderungen<\/th>\n<th>Anmerkungen<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Stickstoffs\u00e4ure<\/td>\n<td>MOS-Klasse<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Salzs\u00e4ure<\/td>\n<td>Garantiertes Reagenz<\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.2.2 Vorbereitete Reagenzien<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-GhL7Lo\" data-scroll-inline-overflow=\"true\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"false\" data-scroll-inline-end-overflow=\"true\">\n<div class=\"table-scroll-container-hgHkfW mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Seriennummer<\/th>\n<th>Name<\/th>\n<th>Herstellungsmethode<\/th>\n<th>Anmerkungen<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>(1 99) Stickstoffs\u00e4urel\u00f6sung<\/td>\n<td>10 ml Salpeters\u00e4ure messen, langsam zu 990 ml deionisiertes Wasser hinzuf\u00fcgen und gut mischen<\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.3 Normen<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.3.1 Lagerl\u00f6sungen<\/h4>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-GhL7Lo\" data-scroll-inline-overflow=\"true\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"false\" data-scroll-inline-end-overflow=\"true\">\n<div class=\"table-scroll-container-hgHkfW mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Seriennummer<\/th>\n<th>Nummer<\/th>\n<th>Name<\/th>\n<th>Technische Anforderungen<\/th>\n<th>Anmerkungen<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>GBW08615<\/td>\n<td>Kupfer Single Element L\u00f6sung Standard Substanz<\/td>\n<td>1000 \u03bcg \/ ml<\/td>\n<td>Nationales Institut f\u00fcr Metrologie, China<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h2 class=\"header-vfC6AV auto-hide-last-sibling-br\">3 Betriebsprozess<\/h2>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.1 Probenverarbeitung<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.1.1 Vorbereitung der Testl\u00f6sung<\/h4>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">W\u00e4gen Sie 0,25 g der Probe, genau 0,00001 g, in einen Verdauungstank. F\u00fcgen Sie 3 ml konzentrierte Stickstoffs\u00e4ure und 9 ml konzentrierte Salzs\u00e4ure hinzu, decken Sie den Verdauungstank ab und ziehen Sie ihn an und legen Sie ihn in ein Mikrowellen-Verdauungsinstrument zur Verdauung. Bereiten Sie eine Leere auf die gleiche Weise vor. Nach Abk\u00fchlung filtern und auf Volumen in einem 25 ml Volumenkolben verd\u00fcnnen und zur Pr\u00fcfung auf die Maschine legen.<\/div>\n<p>&nbsp;<\/p>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Mikrowellenheizungsprogramm<\/div>\n<p>&nbsp;<\/p>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-GhL7Lo\" data-scroll-inline-overflow=\"false\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"true\" data-scroll-inline-end-overflow=\"false\">\n<div class=\"table-scroll-container-hgHkfW mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Schritt<\/th>\n<th>Temperatur \/ \u2103<\/th>\n<th>Haltezeit\/min<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>100<\/td>\n<td>3<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>120<\/td>\n<td>3<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>140<\/td>\n<td>3<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>160<\/td>\n<td>3<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>180<\/td>\n<td>30<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.1.2 Herstellung der Standardl\u00f6sung<\/h4>\n<ol class=\"auto-hide-last-sibling-br\">\n<li>Herstellung von Kupfer-Standardserien: Pipettieren Sie 0,0, 0,025, 0,05, 0,1 und 0,2 ml Kupfer-Standardl\u00f6sung (1000 \u03bcg\/ml) genau in 100 ml Volumenkolben, verd\u00fcnnen Sie die Marke mit (99) Salpeters\u00e4ure und mischen Sie gut. Die Massenkonzentrationen dieser Standardserienl\u00f6sung betragen 0,0, 0,25, 0,5, 1,0 bzw. 2,0 \u03bcg\/ml.<\/li>\n<\/ol>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.2 Probenpr\u00fcfung<\/h3>\n<ol class=\"auto-hide-last-sibling-br\">\n<li>Testbedingungen Referenzbedingungen f\u00fcr die Detektion mit Flammenatomatabsorptionsspektrophotometer<\/li>\n<\/ol>\n<p>&nbsp;<\/p>\n<div class=\"auto-hide-last-sibling-br mdbox-table-root table-container-GhL7Lo\" data-scroll-inline-overflow=\"false\" data-scroll-inline-at-start=\"true\" data-scroll-inline-start-overflow=\"false\" data-scroll-inline-at-end=\"true\" data-scroll-inline-end-overflow=\"false\">\n<div class=\"table-scroll-container-hgHkfW mdbox-table-scroll-container\">\n<table>\n<thead>\n<tr>\n<th>Element<\/th>\n<th>Kupfer<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Wellenl\u00e4nge (nm)<\/td>\n<td>324.7<\/td>\n<\/tr>\n<tr>\n<td>Spektrale Bandbreite (nm)<\/td>\n<td>0.4<\/td>\n<\/tr>\n<tr>\n<td>Elementlampenstrom (mA)<\/td>\n<td>3.0<\/td>\n<\/tr>\n<tr>\n<td>Kraftstoffgash\u00f6he (mm)<\/td>\n<td>6<\/td>\n<\/tr>\n<tr>\n<td>Kraftstoffgasdurchflussrate (mL\/min)<\/td>\n<td>1400<\/td>\n<\/tr>\n<tr>\n<td>Luftkompressordruck (MPa)<\/td>\n<td>0.22<\/td>\n<\/tr>\n<tr>\n<td>Hintergrundkorrekturmethode<\/td>\n<td>Keine<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<ol class=\"auto-hide-last-sibling-br\" start=\"2\">\n<li>Probenpr\u00fcfung Passen Sie das Instrument auf den besten Arbeitszustand an, z\u00fcnden Sie die Flamme an, passen Sie den Kraftstoffgasdurchfluss an, testen Sie die Standard- und Probenl\u00f6sungen in der Reihenfolge, lesen Sie die Daten, geben Sie das Probengewicht ein und \u00fcberpr\u00fcfen und erfassen Sie die Ergebnisse.<\/li>\n<\/ol>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.3 Ergebnisberechnung<\/h3>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\"><img decoding=\"async\" class=\"alignnone wp-image-3806\" src=\"http:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/08\/\u5fae\u4fe1\u56fe\u7247_20250801110810_19904.png\" alt=\"\" width=\"231\" height=\"66\" srcset=\"https:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/08\/\u5fae\u4fe1\u56fe\u7247_20250801110810_19904.png 252w, https:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/08\/\u5fae\u4fe1\u56fe\u7247_20250801110810_19904-18x5.png 18w\" sizes=\"(max-width: 231px) 100vw, 231px\" \/><\/div>\n<p>&nbsp;<\/p>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Wo:<\/div>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">X &#8212; Kupfergehalt in der Probe, Einheit ist Milligramm pro Kilogramm (mg\/kg);<\/div>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">\u03c1 &#8212; Massenkonzentration von Kupfer in der zu pr\u00fcfenden Probenl\u00f6sung, Mikrogramm pro Milliliter (\u03bcg\/ml);<\/div>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">\u03c1\u2080&#8211; Massenkonzentration von Kupfer in der Rohl\u00f6sung, Mikrogramm pro Milliliter (\u03bcg\/ml);<\/div>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">f &#8212; Verd\u00fcnnungsfaktor der Probenveradungsl\u00f6sung;<\/div>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">V &#8212; Gesamtvolumen der Probenveradungsl\u00f6sung, Einheit ist Milliliter (mL);<\/div>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">m &#8212; Masse der Probe, Einheit Gramm (g);<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>1 Method Overview After the sample is digested with aqua regia, the determination is carried out using an air-acetylene flame at a wavelength of 324.7 nm with the instrument. 2 Instruments and Reagents 2.1 Instruments and Equipment 2.1.1 Detection Instruments Serial Number Name Quantity Technical Requirements Accessories 1 Flame Atomic Absorption Spectrophotometer 1 set Copper [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[81,36],"tags":[],"class_list":["post-3805","post","type-post","status-publish","format-standard","hentry","category-petrochemical-and-chemical","category-applications"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.pgeneral.com\/de\/wp-json\/wp\/v2\/posts\/3805","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pgeneral.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pgeneral.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pgeneral.com\/de\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pgeneral.com\/de\/wp-json\/wp\/v2\/comments?post=3805"}],"version-history":[{"count":0,"href":"https:\/\/www.pgeneral.com\/de\/wp-json\/wp\/v2\/posts\/3805\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.pgeneral.com\/de\/wp-json\/wp\/v2\/media?parent=3805"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pgeneral.com\/de\/wp-json\/wp\/v2\/categories?post=3805"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pgeneral.com\/de\/wp-json\/wp\/v2\/tags?post=3805"}],"curies":[{"name":"WP","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}