{"id":3790,"date":"2025-07-28T16:03:51","date_gmt":"2025-07-28T08:03:51","guid":{"rendered":"https:\/\/www.pgeneral.com\/?p=3790"},"modified":"2025-07-28T16:03:51","modified_gmt":"2025-07-28T08:03:51","slug":"determination-of-lead-in-drinking-water-graphite-furnace-atomic-absorption-spectrometry","status":"publish","type":"post","link":"https:\/\/www.pgeneral.com\/de\/applications\/determination-of-lead-in-drinking-water-graphite-furnace-atomic-absorption-spectrometry","title":{"rendered":"Bestimmung des Bleis im Trinkwasser (Atomabsorptionsspektrometrie im Graphitofen)"},"content":{"rendered":"<h2 class=\"header-vfC6AV auto-hide-last-sibling-br\">1. Methodenblick<\/h2>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Nach entsprechender Behandlung wird die Probe in einem Graphitofen zerst\u00e4ubt und die Absorbenz bei 283,3 nm gemessen. Innerhalb eines bestimmten Konzentrationsbereichs ist die Absorbenz von Blei proportional zu seinem Gehalt, und die Quantifizierung erfolgt durch Vergleich zu einer Standardreihe.<\/div>\n<div>\n<h2 class=\"header-vfC6AV auto-hide-last-sibling-br\">2. Instrumente und Reagentien<\/h2>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.1 Instrumente und Ausr\u00fcstung<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.1.1 Pr\u00fcfinstrumente<\/h4>\n<div class=\"auto-hide-last-sibling-br table-container-GhL7Lo\">\n<table>\n<thead>\n<tr>\n<th>Name<\/th>\n<th>Menge<\/th>\n<th>Technische Anforderungen<\/th>\n<th>Zubeh\u00f6r<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Mikropipette<\/td>\n<td>1 jedes<\/td>\n<td>100 \u03bcL ~ 1000 \u03bcL, 1000 \u03bcL ~ 5000 \u03bcL, 5 ~ 50 \u03bcL<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Volumetrischer Kolben<\/td>\n<td>Mehrere<\/td>\n<td>100 ml<\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.1.2 Vorbehandlungsausr\u00fcstung<\/h4>\n<div class=\"auto-hide-last-sibling-br table-container-GhL7Lo\">\n<table>\n<thead>\n<tr>\n<th>Seriennummer.<\/th>\n<th>Name<\/th>\n<th>Menge<\/th>\n<th>Technische Anforderungen<\/th>\n<th>Zubeh\u00f6r<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Mikropipette<\/td>\n<td>1 jedes<\/td>\n<td>100 \u03bcL ~ 1000 \u03bcL, 1000 \u03bcL ~ 5000 \u03bcL, 5 ~ 50 \u03bcL<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Volumetrischer Kolben<\/td>\n<td>Mehrere<\/td>\n<td>100 ml<\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.2 Reagenzien<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.2.1 Reagenzien<\/h4>\n<div class=\"auto-hide-last-sibling-br table-container-GhL7Lo\">\n<table>\n<thead>\n<tr>\n<th>Seriennummer.<\/th>\n<th>Name<\/th>\n<th>Technische Anforderungen<\/th>\n<th>Anmerkungen<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Stickstoffs\u00e4ure<\/td>\n<td>MOS-Klasse<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.3 Referenzstandards<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">2.3.1 Lagerl\u00f6sungen<\/h4>\n<div class=\"auto-hide-last-sibling-br table-container-GhL7Lo\">\n<table>\n<thead>\n<tr>\n<th>Seriennummer.<\/th>\n<th>- Nein. - Nein.<\/th>\n<th>Name<\/th>\n<th>Technische Anforderungen<\/th>\n<th>Anmerkungen<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>GBW 08619<\/td>\n<td>Blei-Einelement-L\u00f6sung Standardsubstanz<\/td>\n<td>1000 \u03bcg\/ml<\/td>\n<td>Nationales Institut f\u00fcr Metrologie, China<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2 class=\"header-vfC6AV auto-hide-last-sibling-br\">3. Betriebsverfahren<\/h2>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.1 Probenverarbeitung<\/h3>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.1.1 Vorbereitung der Testl\u00f6sung<\/h4>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Nehmen Sie 100 ml Wasserprobe in einen Volumenkolben, f\u00fcgen Sie 0,5 ml Salpeters\u00e4ure hinzu und mischen Sie gut. F\u00fchren Sie neben der Probe einen leeren Test durch.<\/div>\n<h4 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.1.2 Vorbereitung von Standardl\u00f6sungen<\/h4>\n<ol class=\"auto-hide-last-sibling-br\">\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Zubereitung der Blei-Standardzwischenl\u00f6sung: Blei-Standardl\u00f6sung (1,0 \u03bcg\/ml): Pipettieren Sie 0,1 ml Blei-Standardl\u00f6sung (1000 \u03bcg\/ml) genau in einen 100 ml Volumenkolben, geben Sie 0,5 ml Salpeters\u00e4ureleisung hinzu, verd\u00fcnnen Sie die Markierung und sch\u00fctteln Sie gut.<\/div>\n<\/li>\n<li>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Herstellung von Blei-Standardserien: Pipettieren Sie 0,0, 0,1, 0,2, 0,3 und 0,4 mL Blei-Standardl\u00f6sung (1,0 \u03bcg\/mL) genau in 10 mL Volumenkolben. F\u00fcgen Sie jeweils 0,5 ml Salpeters\u00e4ureleisung hinzu, verd\u00fcnnen Sie auf die Marke und erhalten Sie Blei-Standardl\u00f6sungen mit Konzentrationen von 0,0, 10,0, 20,0, 30,0 und 40,0 ng\/ml.<\/div>\n<\/li>\n<\/ol>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.2 Probenpr\u00fcfung<\/h3>\n<ol class=\"auto-hide-last-sibling-br\">\n<li>Testbedingungen Referenzbedingungen f\u00fcr die Detektion mit Atomabsorptionsspektrophotometer im Graphitofen<\/li>\n<\/ol>\n<div class=\"auto-hide-last-sibling-br table-container-GhL7Lo\">\n<table>\n<thead>\n<tr>\n<th>Element<\/th>\n<th>Blei<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Wellenl\u00e4nge (nm)<\/td>\n<td>283.3<\/td>\n<\/tr>\n<tr>\n<td>Spektrale Bandbreite (nm)<\/td>\n<td>0.4<\/td>\n<\/tr>\n<tr>\n<td>Elementlampenstrom (mA)<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>Hintergrundkorrekturmethode<\/td>\n<td>Deuteriumlampe<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<\/div>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\"><strong>Graphitofenheizungsprogramm<\/strong><\/div>\n<p>&nbsp;<\/p>\n<div class=\"auto-hide-last-sibling-br table-container-GhL7Lo\">\n<table>\n<thead>\n<tr>\n<th>Schritt<\/th>\n<th>Verfahren<\/th>\n<th>Temperatur (\u2103)<\/th>\n<th>Rampezeit(en)<\/th>\n<th>Haltezeit(en)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Trocknung<\/td>\n<td>120<\/td>\n<td>10<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Ashing<\/td>\n<td>450<\/td>\n<td>10<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Atomisierung<\/td>\n<td>1800<\/td>\n<td>0<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>Reinigung<\/td>\n<td>1900<\/td>\n<td>1<\/td>\n<td>2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<ol class=\"auto-hide-last-sibling-br\" start=\"2\">\n<li>Probentesting Bestimmen Sie die Absorbenz von Standardl\u00f6sungen, leeren Testl\u00f6sungen und Testl\u00f6sungen in der Reihenfolge. Die Absorbenz der Null-Standardl\u00f6sung wird von der Absorbenz jeder Standardl\u00f6sung subtrahiert. Plottieren Sie eine Arbeitskurve mit der Massenkonzentration als Abszisse und der entsprechenden Absorbenz als Ordinate. Basierend auf der gemessenen Absorbenz der Testl\u00f6sung finden Sie die Massenkonzentration von Blei aus der Arbeitskurve.<\/li>\n<\/ol>\n<h3 class=\"header-vfC6AV auto-hide-last-sibling-br\">3.3 Ergebnisberechnung<\/h3>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Formel:<\/div>\n<p><img decoding=\"async\" class=\"alignnone  wp-image-3791\" src=\"http:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/07\/2222\u5fae\u4fe1\u56fe\u7247_20250728160213_3807-300x128.png\" alt=\"\" width=\"199\" height=\"85\" srcset=\"https:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/07\/2222\u5fae\u4fe1\u56fe\u7247_20250728160213_3807-300x129.png 300w, https:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/07\/2222\u5fae\u4fe1\u56fe\u7247_20250728160213_3807-18x8.png 18w, https:\/\/www.pgeneral.com\/wp-content\/uploads\/2025\/07\/2222\u5fae\u4fe1\u56fe\u7247_20250728160213_3807.png 303w\" sizes=\"(max-width: 199px) 100vw, 199px\" \/><\/p>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">Wo:<\/div>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">\u03c1 \u2014 Massenkonzentration von Blei in der Wasserprobe, in Milligramm pro Liter (mg\/L);<\/div>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\"><span class=\"container-rkuXQi math-inline\" data-custom-copy-text=\"\\(\\rho_1\\)\">\u03c11<\/span>\u2014 Massenkonzentration von Blei in der aus der Standardkurve gewonnenen Wasserprobe in Nanogramm pro Milliliter (ng\/ml);<\/div>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\"><span class=\"container-rkuXQi math-inline\" data-custom-copy-text=\"\\(V_1\\)\">V1<\/span>\u00a0\u2014 Volumen der Probenl\u00f6sung zur Bestimmung in Millilitern (mL);<\/div>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\"><span class=\"container-rkuXQi math-inline single-Z69glH\" data-custom-copy-text=\"V\">V<\/span>\u00a0\u2014 Volumen der urspr\u00fcnglichen Wasserprobe in Millilitern (mL);<\/div>\n<div class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\">1000 \u2014 Umrechnungsfaktor.<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>1. Method Overview After appropriate treatment, the sample is atomized in a graphite furnace, and the absorbance is measured at 283.3 nm. Within a certain concentration range, the absorbance of lead is proportional to its content, and quantification is performed by comparison with a standard series. 2. Instruments and Reagents 2.1 Instruments and Equipment 2.1.1 [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[36,73],"tags":[],"class_list":["post-3790","post","type-post","status-publish","format-standard","hentry","category-applications","category-food-and-drugs"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.pgeneral.com\/de\/wp-json\/wp\/v2\/posts\/3790","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pgeneral.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pgeneral.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pgeneral.com\/de\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pgeneral.com\/de\/wp-json\/wp\/v2\/comments?post=3790"}],"version-history":[{"count":0,"href":"https:\/\/www.pgeneral.com\/de\/wp-json\/wp\/v2\/posts\/3790\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.pgeneral.com\/de\/wp-json\/wp\/v2\/media?parent=3790"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pgeneral.com\/de\/wp-json\/wp\/v2\/categories?post=3790"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pgeneral.com\/de\/wp-json\/wp\/v2\/tags?post=3790"}],"curies":[{"name":"WP","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}